The HC60NG is a radio frequency (RF) device and for the best perform-
ance should be installed in an open space. Leave at least 30cm distance 
from any metal objects including wall boxes and the boiler. 

2

NOTE:

The HC60NG contains no user serviceable parts. It should be opened and 
installed by qualified installer only.

WARNING:

Electrostatic sensitive device! Do not touch the circuit board.

> 7mm 

< 7mm 

1.0-2.5mm²

6mm max.

NOTE:

Install in accordance with local wiring regulations

CAUTION:

Observe ambient temperature and current limits (see HC60NG wiring label)

 Section 4:  

HC60NG Relay Module

Caution!

!

When selecting the operating site ensure that the distance to wireless 
devices such as wireless headphones, cordless phones etc. is approx.  
1-2m according to the DECT standard.

The  HC60NG  Relay  Module  is  an  integral  part  of  the  CM  Zone  Control  System.  It  is 
designed to control a Domestic Boiler, Valve, pump or Electric Heating appliances.

In the standard CM Zone Pack the HC60NG Relay Module is configured to control a Boiler 
based upon demand signals received from the HR80UK Radiator Controllers either directly 
or via a ‘Y Plan’ / ‘S Plan’ connection described below.

For control of other applications see 

Section 8: Changing the Configuration

.

Please note:  Maximum  wire  size  2.5mm

2

.  SPDT  relay  suitable  for 

24...230V~, 10A resistive, 3A inductive

Honeywell ‘Y Plan’ Connections

Honeywell ‘S Plan’ Connections

NOTE:

For existing ’Y Plan’ remove only Room Thermostat connections from 
Junction Box Terminals and replace with Connections to HC60NG.

NOTE:

For existing ’S Plan’ remove only Room Thermostat connections from 
Junction Box Terminals and replace with Connections to HC60NG.

HC60NG Relay Module

Typical Burner / Boiler connections

a. Burner (direct control)

HC60NG

b. Combi boiler

HC60NG

1  2  3  4  5  6  7  8  9  10

Typical ‘Y Plan’ Junction Box

HC60NG

1  2  3  4  5  6  7  8  9  10

Typical ‘S Plan’ Junction Box

HC60NG

Summary of Contents for YZ667A1060

Page 1: ... and three bound to Zone 2 The System can be expanded or modified and the methods used are described within this Guide To get the best from the installed system it is recommended to use Honeywell VT15 VT117 or VT200 TRV bodies and a Honeywell DU145 Automatic Bypass Valve For application support please contact your nearest Honeywell salesman for technical assistance please contact the Honeywell Tec...

Page 2: ...HR80UK Radiator controllers labelled 2 HC60NG Relay box CM67z Room Unit To change this factory configuration or to add components please see Section 8 Changing the Configuration A typical traditional system with open vented hot water storage tank Conventional Boilers These are used in traditional central heating systems in the UK A typical COMBI system Combination Boilers With a combination boiler...

Page 3: ...ol System It is designed to control a Domestic Boiler Valve pump or Electric Heating appliances In the standard CM Zone Pack the HC60NG Relay Module is configured to control a Boiler based upon demand signals received from the HR80UK Radiator Controllers either directly or via a Y Plan S Plan connection described below For control of other applications see Section 8 Changing the Configuration Plea...

Page 4: ...r normal operation refer to the CM Zone User Guide MON TUE WED THU FRI SAT SUN Setting the clock Move the CM67z slider to DATE position When setting the date and time for the first time after batteries were inserted the zone controller display will flash as shown Press the or buttons to set the current year e g 03 2003 Press the TEMP button to go to the month Press the or to set the current month ...

Page 5: ...M Zone Pack the HR80 s Radiator Controllers are pre bound to each zone as indicated by the zone number label To add additional HR80UK Radiator Controllers to a zone refer to Section 8 Changing the Configuration Turn the locking knob a and separate the operating module from the coupling module a 1 Turn the coupling module wheel a anti clockwise approx 3 rotations until the nose b reaches the end st...

Page 6: ...as close as pos sible to the location where it will be used Wall 6 10 dB Wall 6 10 dB Wall 6 10 dB 60dB 50dB 40dB 30dB 5dB 15dB 25dB 35dB Ceiling 10 25 dB Max Signal Length 30 meters Typical example of Building Fabric Signal losses CM67z Room Unit to HR80UK Radiator Controllers 1 Move the CM67z slider to AUTO position 2 Set the zone 1 setpoint to 5 C by pressing the TEMP button Press the z1 z2 but...

Page 7: ...point Limit Lower Setpoint Limit Temperature Offset Proportional Band Width Optimisation enable Loss of Communications Instruction CM67z built in temperature sensor use HR80UK Window Open Function HR80UK Local Override Function Automatic Summer Winter Time Changeover Reset Installer Mode Parameters to Defaults Identifier 1 CL 2 rP 3 Cl 3 Ot 6 tS 7 PE 8 Cr 9 Sn 10 UL 11 LL 12 tO 14 Pb 15 OP 16 LC 1...

Page 8: ...ations until the nose b reaches the end stop c a c b Attach the appropriate Zone Label and press the Binding Button Software version is displayed and the RF symbol flashes Example Zone 1 Repete for all additional HR80 s to bind to this zone Install batteries into the operating unit Note Check correct polarity Fit the coupling module a to the TRV body b and tighten by hand For Adaptors see Section ...

Page 9: ... of the zone valve controller will be switched off NOTE Install in accordance with local wiring regulations CAUTION Observe ambient temperature and current limits see HC60NG wiring label a Thermal actuator b Zone valve c Zone valve 8 4 Adding a HC60NG Zone valve controller The HC60NG relay module can also be configured for control ling a zone valve This is restricted to zone 1 only Before the bind...

Page 10: ...batteries Wrong battery orientation Improper battery compartment insertion CM67z only Exhausted batteries Batteries need replacing Fault in the CM67z room unit Remedy Repeat the binding procedure following the installation instructions Repeat the binding procedure keeping approx 1 m distance between CM67z and HR80UK Repeat the binding procedure following the installation instructions Repeat the bi...

Page 11: ...on Check the boiler and HC60NG power supply as well as electrical connection between the boiler and HC60NG Hook the room unit back on the wall bracket or return the room unit on the table stand to the position where communication was reliable Call the Honeywell Technical Help Desk details on the back page NOTE The boiler can be controlled manually when RF communication is lost Press the HC60NG pus...

Page 12: ...d designs registered trade marks unregistered trade marks and copyrights and also include the following UK registration rights UK patent application number 98062207 8 UK registered design numbers 2073334 2073340 and 2073343 Useful References http www honeywelluk com Honeywell UK website http www cm zone com uk CM Zone website Technical Help Desk 08457 678999 This product can be used in the followi...