XNX Universal Transmitter
Specifications
138
Electrical
Operating Voltage
EC/mV: 16V to 32V (24V nominal) ** Startup/Normal values **
IR: 18V to 32V (24V nominal) ** Startup/Normal values **
Power
Consumption
Configuration
Max Power
Inrush
XNX EC
6.2 w
<1A, <10ms@24VDC
XNX mV
6.5 w
<750mA <2ms@24VDC
XNX IR (Optima)
9.7w
<1A, <10ms@24VDC
XNX IR (Excel)
13.2w
<1A, <10ms@24VDC
Termination
Crimp style pluggable with retaining screws, 12-28 AWG (2.5 to 0.5mm
2
)
with Shorting Jumpers: 14-28 AWG (2.0 to 0.5mm
2
)
NOTE:
To maintain EMC integrity, wiring must be shielded by either an integral
shield or run through conduit or pipe. Shield must provide 90% coverage.
Signal
Standard
HART over 3-wire 4-20 mA (sink, source, or isolated)
Optional
Modbus over RS-485
20 mA
HART over 3-wire 4-20mA (sink, source, or isolated)
compliant with NAMUR NE43
Cable Ports
5 – (2 right, 2 left, 1 bottom) Available in ¾” NPT, or M25
Recommended
Cable
Distance Considerations for Installation
section.
Unpowered
battery life
(Real Time Clock) 3 years at rated storage temperature
Construction
Material
Marine grade aluminum alloy or SS316. 5-coat painted finish.
Dimensions
159 x 197 x 113.8 mm / 6.138 x 7.75 x 4.48 inches
Weight
2.27 kg (5 lb) Aluminum
5 kg (11 lb) Stainless
Mounting
XNX
®
Enclosure
Integral Mounting Lugs for Wall- or Optional Pipe-Mount, Optional Wall/
Ceiling Bracket
User Interface
Standard
Custom Backlit LCD, magnetic wand operation of local user interface
Optional
HART Handheld with IS Port
Environmental - Transmitter Operating
IP Rating
IP66
Temperature*
Transmitter: -40°C to +65°C (-40°F to +149°F)
MPD**-CB1: -40°C to +65°C (-40°F to +149°F)
MPD**-I**: -20°C to +50°C (-4°F to +122°F)
Humidity
0 to 99% RH non-condensing
Pressure
80 kPa to 120 kPa
Air Speed
0-6 m/sec
*Operating temperatures will be limited by the sensors. See
EC Sensor Performance Data, Factory
EC Sensor Performance Data, DEKRA EXAM Verified
for more
information.
Environmental - Transmitter Storage
Temperature
-40°C to +65°C / -40°F to +149°F
Humidity
0 to 99% RH non-condensing
Product Specifications
Summary of Contents for XNX-AM Series
Page 2: ...This page is intentionally left blank ...
Page 7: ...XNX Universal Transmitter Safety and Information 5 Safety and Information ...
Page 12: ...XNX Universal Transmitter XNX Universal Transmitter Technical Manual 10 Introduction ...
Page 27: ...XNX Universal Transmitter Introduction 25 Menu Navigation ...
Page 102: ...XNX Universal Transmitter XNX Universal Transmitter Technical Manual 100 Calibration ...
Page 118: ...XNX Universal Transmitter XNX Universal Transmitter Technical Manual 116 Maintenance ...
Page 122: ...XNX Universal Transmitter XNX Universal Transmitter Technical Manual 120 Warnings and Faults ...
Page 139: ...XNX Universal Transmitter XNX Universal Transmitter Technical Manual 137 Specifications ...
Page 174: ...XNX Universal Transmitter XNX Universal Transmitter Technical Manual 172 Control Drawings ...
Page 177: ...XNX Universal Transmitter Control Drawings 175 ...
Page 179: ...XNX Universal Transmitter Control Drawings 177 Remote Sensor Mount ...
Page 180: ...XNX Universal Transmitter XNX Universal Transmitter Technical Manual 178 HART Protocol ...
Page 193: ...XNX Universal Transmitter XNX Universal Transmitter Technical Manual 191 Modbus Protocol ...
Page 200: ...XNX Universal Transmitter XNX Universal Transmitter Technical Manual 198 Warranty ...
Page 202: ...XNX Universal Transmitter XNX Universal Transmitter Technical Manual 200 Index ...