XNX Universal Transmitter
Specifications
144
Other EC Sensors
Gas
Cartridge
Part Number
Selectable Full
Scale Range
(Display and
4-20mA Full
Scale)
Default
Range
Range
Incre-
ments
Lower
Alarm
Limit
Lower
Detection
Limit
Zero
Deviation
Selectable
Cal Gas
Range
Default
Cal
Point
Response
Time T50
(sec)
Response
Time T90
(sec)
Accuracy1
Typical
Accuracy
@ Lowest
Alarm
Level
Operating Temperature
Operating Humidity
EC Sensor
Expected
LIfe
(months)
Min
Max
Min
Max
HCl
Hydrogen chloride
XNXXSR1SS
10.0 to 20.0 ppm 10.0 ppm 1.0 ppm
2.0 ppm
0.6 ppm
-1.0 ppm
30 to 70%
of the
selected full
scale range
5.0 ppm
<45
2, 3
<150
2, 3
<+/-1.0 ppm
or 20%
of applied gas
2, 3
<+/-1.0 @
3 ppm
-20°C/-4°F
40°C/104°F
15% RH
90% RH
12
H
2
S (Low) Hydrogen sulfide
XNXXSH3SS
n/a
15.0 ppm
n/a
3.0 ppm
1.0 ppm
-2.5 ppm
10 ppm
<20
<40
<+/-0.3 ppm
<+/-0.3 @
3 ppm
-40°C / -40°F 55°C / 131°F
15% RH
90% RH
12
SO
2
Sulfur dioxide
XNXXSS1SS
5.0 to 20.0 ppm 15.0 ppm 5.0 ppm
2.0 ppm
0.6 ppm
-1.0 ppm
5.0 ppm
<15
<30
<+/-0.3 ppm
<+/-0.3 @
2 ppm
-40°C / -40°F 55°C / 131°F
15% RH
90% RH
24
SO
2
(High)
Sulfur dioxide
XNXXSS2SS
20.0 to 50.0 ppm 50.0 ppm 10.0 ppm 5.0 ppm
1.5 ppm
-2.5 ppm
25 ppm
<15
<30
<+/-0.6 ppm
<+/-0.6 @
5 ppm
-40°C / -40°F 55°C / 131°F
15% RH
90% RH
24
NH
3
Ammonia
XNXXSA1SS
50 to 200 ppm
200 ppm 50 ppm
20 ppm
6 ppm
-10 ppm
100 ppm
<60
<180
<+/-4 ppm
<+/-4 @
20 ppm
-20°C / -4°F 40°C / 104°F
15% RH
90% RH
12
NH
3
(High)
Ammonia
XNXXSA2SS
200 to 1000 ppm
1,000
ppm
50 ppm
100 ppm
30 ppm
-50 ppm
300 ppm
<60
<180
<+/-20 ppm
<+/-20 @
100 ppm
-20°C / -4°F 40°C / 104°F
15% RH
90% RH
12
Cl
2
2
Chlorine
XNXXSL2SS
n/a
5.00 ppm
n/a
0.50 ppm 0.15 ppm -0.25 ppm
2.0 ppm
<20
<60
<+/-0.2 ppm
<+/-0.20 @
0.50 ppm
-10°C / 14°F 55°C / 131°F
15% RH
90% RH
24
Cl
2
(High)2
Chlorine
XNXXSL1SS
5.0 to 20.0 ppm
5.0 ppm 5.0 ppm
1.0 ppm
0.6 ppm
-1.0 ppm
2.0 ppm
<20
<30
<+/-0.2 ppm
<+/-0.2 @
1 ppm
-10°C / 14°F 55°C / 131°F
15% RH
90% RH
24
ClO
2
2
Chlorine dioxide
XNXXSX1SS
n/a
1.00 ppm
n/a
0.10 ppm 0.03 ppm -0.05 ppm
0.5 ppm
<30
<120
<+/-30%
<+/-0.03 @
0.1 ppm
-20°C / -4°F 55°C / 131°F
15% RH
90% RH
24
NO
Nitrogen
monoxide
XNXXSM1SS
n/a
100 ppm
n/a
10 ppm
3 ppm
-5 ppm
50 ppm
<15
<30
<+/-2 ppm
<+/-2.0 @
10 ppm
-20°C / -4°F 55°C / 131°F
15% RH
90% RH
24
NO
2
Nitrogen dioxide
XNXXSN1SS
5.0 to 50.0 ppm 10.0 ppm 5.0 ppm
5.0 ppm
1.5 ppm
-2.5 ppm
5 ppm
<15
<30
<+/-0.2 ppm
<+/-0.2 @
5 ppm
-20°C / -4°F 55°C / 131°F
15% RH
90% RH
24
H
2
Hydrogen
XNXXSG1SS
n/a
1,000
ppm
n/a
100 ppm
30 ppm
-50 ppm
500 ppm
<60
<902
<+/-8 ppm
<+/-8 @
100 ppm
-20°C / -4°F 55°C / 131°F
15% RH
90% RH
24
H
2
(High) Hydrogen
XNXXSG2SS
n/a
10,000
ppm
n/a
1000 ppm 300 ppm
-500 ppm
5000 ppm
<15
<30
<+/-150 ppm
<+/-150 @
1000 ppm
-20°C / -4°F 55°C / 131°F
15% RH
90% RH
24
HF2
Hydrogen fluoride
XNXXSF1SS
10.0 to 12.0 ppm 12.0 ppm 0.1 ppm
1.5 ppm
0.4 ppm
-0.6 ppm
5.0 ppm
120
<240
<+/-0.5 ppm
<+/-0.5 @
1.5 ppm
-20°C / -4°F 55°C / 131°F
20% RH
75% RH
12
PH
3
Phosphine
XNXXSP1SS
n/a
1.20 ppm
n/a
0.15 ppm 0.04 ppm -0.06 ppm
0.5ppm
<15
<30
<+/- 0.02 ppm
<+/-0.02 @
0.15 ppm
-20°C / -4°F 40°C / 104°F
10% RH
90% RH
24
HCN
Hydrogen cyanide
XNXXSY1SS
n/a
30.0 ppm
n/a
2.4 ppm
1.0 ppm
-2.5 ppm
10.0 ppm
<35
<200
<±0.4 ppm
0.4 ppm
-20°C / -4°F 55°C / 131°F
15% RH
90% RH
24
F
2
Fluorine
XNXXSU1SS
n/a
4.00 ppm
n/a
0.50 ppm 0.36 ppm -0.72 ppm
2.0 ppm
<5
<30
<±0.03 ppm
0.3 ppm
-20°C / -4°F 55°C / 131°F
15% RH
90% RH
18
O
3
Ozone
XNXXSZ1SS
n/a
0.400
ppm
n/a
0.048 ppm 0.032 ppm -0.080 ppm
0.200
ppm
<15
4
<60
4
<±0.003 ppm 0.003 ppm
5
-20°C / -4°F 55°C / 131°F
15% RH
90% RH
18
EtO
Ethylene oxide
XNXXSE1SS
20.0 to 50.0 ppm 25.0 ppm 5.0 ppm
3.0 ppm
1.0 ppm
-2.5 ppm
10.0 ppm
<40
4
<125
4
<±0.3 ppm
0.3 ppm
5
-20°C / -4°F 55°C / 131°F
15% RH
90% RH
24
See footnotes and notes on the following page.
Summary of Contents for XNX-AM Series
Page 2: ...This page is intentionally left blank ...
Page 7: ...XNX Universal Transmitter Safety and Information 5 Safety and Information ...
Page 12: ...XNX Universal Transmitter XNX Universal Transmitter Technical Manual 10 Introduction ...
Page 27: ...XNX Universal Transmitter Introduction 25 Menu Navigation ...
Page 102: ...XNX Universal Transmitter XNX Universal Transmitter Technical Manual 100 Calibration ...
Page 118: ...XNX Universal Transmitter XNX Universal Transmitter Technical Manual 116 Maintenance ...
Page 122: ...XNX Universal Transmitter XNX Universal Transmitter Technical Manual 120 Warnings and Faults ...
Page 139: ...XNX Universal Transmitter XNX Universal Transmitter Technical Manual 137 Specifications ...
Page 174: ...XNX Universal Transmitter XNX Universal Transmitter Technical Manual 172 Control Drawings ...
Page 177: ...XNX Universal Transmitter Control Drawings 175 ...
Page 179: ...XNX Universal Transmitter Control Drawings 177 Remote Sensor Mount ...
Page 180: ...XNX Universal Transmitter XNX Universal Transmitter Technical Manual 178 HART Protocol ...
Page 193: ...XNX Universal Transmitter XNX Universal Transmitter Technical Manual 191 Modbus Protocol ...
Page 200: ...XNX Universal Transmitter XNX Universal Transmitter Technical Manual 198 Warranty ...
Page 202: ...XNX Universal Transmitter XNX Universal Transmitter Technical Manual 200 Index ...