Suffix

If you want a carriage return after the bar code, scan the 

Add CR 

Suffix bar code

.  To add a tab after the bar code, scan the 

Add Tab 

Suffix

 bar code.  Otherwise, scan the 

Remove Suffix

 bar code to 

remove the suffixes.

Add Code ID Prefix to all Symbologies

Scan the following bar code if you wish to add a Code ID prefix to all 
symbologies at once.

Note: For a complete list of Code IDs, see the User’s Guide for your 

product at our website,  

www.honeywellaidc.com.

Add CR Suffix

Remove Suffix

Add Tab Suffix

Add Code ID Prefix To All Symbologies

(Temporary)

Summary of Contents for XENON 1902

Page 1: ... com Monday Friday 6 AM to 5 PM Pacific Time Bulk Discounts FREE SHIPPING SE Habla Español Free ground shipping to the continental USA on orders over 100 For Help Call 1 800 241 6264 Honeywell Quick Start Guide Xenon 1902 THIS DOWNLOAD APPLIES TO THE FOLLOWING Xenon 1902 Xenon 1902 Color ...

Page 2: ... honeywellaidc com per l italiano Für Deutsch gehe zu www honeywellaidc com Ir a www honeywellaidc com para español Para Português acesse www honeywellaidc com br Перейти на русскоязычный сайт www honeywellaidc com 日本語 www honeywellaidc com をご覧ください 如要到中国 www honeywellaidc com 简体 查看繁体版请登陆 www honeywellaidc com 한글 www honeywellaidc com 로 이동합니다 ...

Page 3: ...aidc com Getting Started Turn off the computer s power before connecting the base then power up the computer once the base is fully connected When the base is connected and powered up put the scanner in the base to establish a link The green LED on the base flashes to indicate the scanner s battery is charging Power Supply Assembly if included ...

Page 4: ...Connecting the Scanner USB Keyboard Wedge ...

Page 5: ...RS232 Serial Port RS485 ...

Page 6: ... when it is farther from the code Hold the scanner close to smaller bar codes and farther away from large bar codes to get a proper read If the bar code is highly reflective e g laminated you may need to tilt the scanner at an angle so the bar code can be scanned Note If the scanner beeps 3 times when scanning a bar code the link has not been established If the scanner beeps once the link has been...

Page 7: ...ur website www honeywellaidc com Keyboard Country Scan the Program Keyboard Country bar code below then scan the numeric bar code s from page 2 then the Save bar code to program the keyboard for your country As a general rule the following characters are not supported by the scanner for countries other than the United States Country Code Scan Country Code Scan Belgium 1 Italy 5 Denmark 8 Norway 9 ...

Page 8: ...ed if they are inadvertently placed into the base If you do place a different scanner into the base it will charge the scanner but the scanner will not be linked To use a different scanner you need to unlink the original scanner by scanning the Unlink Scanner bar code Finland 2 Spain 10 France 3 Switzerland 6 Germany Austria 4 USA Default 0 Great Britain 7 Country Code Scan Country Code Scan Save ...

Page 9: ...l be overridden the broken or lost scanner s link with the base will be removed and the new scanner will be linked Unlinking the Scanner If the base has a scanner linked to it that scanner must be unlinked before a new scanner can be linked Once the previous scanner is unlinked it will no longer communicate with the base Scan the Unlink Scanner bar code to unlink a scanner Override Locked Scanner ...

Page 10: ...rigger to read or Presentation mode the scanner is activated when it sees a bar code Streaming Presentation When in Streaming Presentation mode the scanner leaves the scan illumination on all the time and continuously searches for bar codes Manual Trigger Normal Default Presentation Mode Streaming Presentation Mode ...

Page 11: ...move Suffix bar code to remove the suffixes Add Code ID Prefix to all Symbologies Scan the following bar code if you wish to add a Code ID prefix to all symbologies at once Note For a complete list of Code IDs see the User s Guide for your product at our website www honeywellaidc com Add CR Suffix Remove Suffix Add Tab Suffix Add Code ID Prefix To All Symbologies Temporary ...

Page 12: ...ained within the scanned data the scanner transmits the function code to the terminal Charts of these function codes are provided in your User s Guide When the scanner is in keyboard wedge mode the scan code is converted to a key code before it is transmitted Enable Default Disable ...

Page 13: ...e www honeywellaidc com 1 Scan the Enter Data Format symbol 2 Primary Alternate Format scan 0 for Primary Format 3 Terminal Type scan 099 for any terminal type 4 Code I D scan 99 for any bar code type 5 Length scan 9999 for any length bar code 6 Editor commands use the Programming Chart that follows 7 Scan Save to save your entries Enter Data Format Clear All Data Formats Save ...

Page 14: ...Programming Chart 0 2 1 4 3 5 6 7 ...

Page 15: ...A B C D E F 9 8 Save ...

Page 16: ...well International Inc HII reserves the right to make changes in specifications and other information contained in this document without prior notice and the reader should in all cases consult HII to determine whether any such changes have been made The information in this publication does not represent a commitment on the part of HII HII shall not be liable for technical or editorial errors or om...

Page 17: ...Other product names or marks mentioned in this document may be trademarks or registered trademarks of other companies and are the property of their respective owners Web Address www honeywellaidc com ...

Reviews: