background image

M_XXXXXX_EN_1.0 

 

High Efficiency Power Amplifier 

X-DA4125 

User Manual 

 

 

 

Summary of Contents for X-DA4125

Page 1: ...M_XXXXXX_EN_1 0 High Efficiency Power Amplifier X DA4125 User Manual ...

Page 2: ......

Page 3: ...e contents of this document are subject to revision without notice due to continued progress in methodology design and manufacturing Honeywell shall have no liability for any error or damage of any kind resulting from the use of this document Trademark List All trademarks mentioned herein are the property of their respective owners These are shown in the document Trademark Information ...

Page 4: ......

Page 5: ... it Safety Guidelines Do not expose the appliance to rain or moisture to avoid causing a fire or an electric shock Safety Precautions For the installation operation and use of this product please carefully read the following precautions Electrical Safety The product installation and use must comply with local electrical safety regulations Honeywell assumes no liability for user errors or misuse th...

Page 6: ...rong configuration must match If the plug outlet does not match the prong configuration of the plug the outlet must be replaced with one that matches the plug The appliance must have a sufficient power source and an independent grounding wire Note that the equipment must be properly grounded Otherwise the equipment could fail to work properly or be damaged When the power is turned on high voltage ...

Page 7: ...uncil directive 2004 108 EC Electromagnetic emissions EN55013 2001 A1 2003 A2 2006 EN61000 3 2 2006 A1 2009 A2 2009 EN61000 3 3 2008 Electromagnetic immunity EN55020 2007 Electrostatic Discharge Immunity EN55020 2007 Electrical Fast Transient Burst Immunity EN55020 2007 Immunity from Radiated Fields EN55020 2007 Immunity from Conducted Voltages ...

Page 8: ......

Page 9: ...es 3 Power Supply Protection 3 Overheating Protection 4 Overload and Short Circuit Protection 4 Fault Detection and Fault Logs 4 Self Test Function 4 Applications 4 For the X 618 System 4 2 Package Contents 5 3 User Interface 6 Front Panel 6 Rear Panel 7 4 Installation 9 Preparing for Installation 9 Tools 9 Materials 10 Cables and Wires 10 Package Inspection 10 Hardware Installation 10 Connecting ...

Page 10: ...ii 5 Technical Specifications 16 ...

Page 11: ... preparation instructions hardware installation procedures and other related information Chapter 5 Technical Specifications X DA4125 High Efficiency Power Amplifier technical specifications Audience This manual is primarily intended for personnel who require information regarding the installation operation and maintenance of the X DA4125 High Efficiency Power Amplifier How to Use This Manual Pictu...

Page 12: ......

Page 13: ... mode Able to automatically limit output voltage Functions The DA includes the following main functions Main and Backup Power Supplies Power Supply Protection Error Reference source not found Overload and Short Circuit Protection Fault Detection and Fault Logs Self Test Function Main and Backup Power Supplies The DA includes main and backup power supplies Typically the main power supply is used an...

Page 14: ...ch individual channel Fault Detection and Fault Logs The main power supply of the DA can detect power failures and overheating to protect it from short circuits and circuit overloads When the DA detects a failure a fault is signaled until the problem is fixed The current state of the DA is shown on the front panel and if a fault is signaled it is displayed Self Test Function The front panel user i...

Page 15: ...nal to the DA which monitors the system for faults 2 Package Contents Please check to make sure all components listed below in Table 1 are included in the box in which the DA and associated components arrive If an item is missing please contact the appropriate vendor Table 1 DA Package Contents Number Component Name Quantity 1 X DA4125 High Efficiency Power Amplifier 1 2 Network cable 2 3 Input ca...

Page 16: ...w backup power supply has experienced a fault 4 CH1 PROTECT DA protection indicator light When the DA overheats experiences over current over voltage or undervoltage the DA automatically protects the equipment In this case the light turns yellow 5 CLIP Peak clipping indicator light When the input signal exceeds the rated peak value the indicator light turns red 6 SIGNAL Signal indicator light This...

Page 17: ...llow 14 CLIP Peak clipping indicator light When the input signal exceeds the rated peak value the indicator light turns red 15 SIGNAL Signal indicator light This light turns green and fluctuates depending upon the signal intensity If the light is off there is no input signal Rear Panel The rear panel of the DA is shown in Figure 33 Table 3 lists the rear panel ports and their descriptions Figure 3...

Page 18: ...0V high impedance audio output 70V 70V high impedance audio output COM Common CH4 100V 100V high impedance audio output 70V 70V high impedance audio output COM Common 5 Cooling fan 6 Main power supply power port Supplies electricity to the main power supply 7 Backup power supply power port Supplies electricity to the backup power supply 8 Grounding terminal Connects the grounding wire 9 Power swit...

Page 19: ...D 0V 12 Balanced positive input of CH3 13 Balanced negative input of CH3 14 GND 0V 15 VCC 12V 24V powered by an external device 16 Self test port When the DA output voltage is VCC 12V 24V the DA is being self tested When the DA has no input voltage the DA is working normally 4 Installation This chapter describes how to install the DA hardware in step by step instructions Preparing for Installation...

Page 20: ...ng to the installation situation and environment For the installation of the DA prepare the following cables Backup power cable The backup power cable and main power cable are required to have matching specifications Audio output cable The cable should be unshielded Package Inspection Check the packaging and make sure all items specified on the Package Contents list are intact see Chapter 2 If an ...

Page 21: ... Power and data wires must be separated and not be wrapped in the same cable s insulation Keeping the power and data cables separate helps to avoid signal interference Grounding Cable The grounding cable connects to the DA grounding cable port Notice Do not connect the grounding output cable with the grounding input cable as this action causes a short circuit to occur Audio Input Cable The user ca...

Page 22: ...A has a balanced input connection A balanced connection is recommended to reduce AC power interference especially when using a long cable For short cables that have an unbalanced connection the signal impedance should be less than 600 ohms The following steps describe connecting a balanced input connection 1 Pull the input cable through the terminal protection cover as shown in Figure6 Figure 6 Pu...

Page 23: ...als Output Cable 1 Pull the output cable through the terminal protection cover as shown in Figure 6 2 Strip 7 mm of insulation off the output cable and connect it to the output terminal as shown in Figure 9 Figure 9 Output connection terminal 3 Connect the prepared output terminal to the DA output port 4 Attach the terminal protection cover and tighten the screws as show in Figure 10 ...

Page 24: ...he other end of the output cable to the DCS PA audio input terminal as shown in Figure 11 Figure 11 Output cable connection Main Power Cable 1 Strip 7 mm of insulation off one end of the AC power cable and connect it to the main power terminal as shown in Figure 12 ...

Page 25: ...terminal to the DA backup power cable port 4 Connect the other end of the backup power cable to the main power supply equipment Completing Installation and Commissioning Once the DA hardware and cables are installed complete the following commissioning procedures 1 Set the audio volume to a minimum level 2 Press the DA front panel power button The POWER indicator light comes on to show the DA is n...

Page 26: ... signal is too high the speakers could be damaged 5 Technical Specifications The DA technical specifications are shown below in Table 5 Table 5 X DA4125 technical specifications Parameter Value Nominal output power 4 125W Main power supply voltage 220V 240V 50 60Hz Backup power supply voltage 220V 240V 50 60Hz Power consumption 720W Main power supply protection T10AL 250V Speaker output voltage 10...

Page 27: ...Storage temperature 10 C 55 C 14 F 131 F Cooling method Air cooling Product dimensions width height depth 416 W 88 H 483 D mm Package dimensions width height depth 489 W 186 H 568 D mm Net weight 12 9Kg Gross weight 16Kg ...

Page 28: ......

Page 29: ...www honeywellav com Address No 257 Junye Road Guangzhou GETDD East 510530 China Tel 86 0 20 2839 9600 Fax 86 0 20 2820 8706 2011 Honeywell International Inc All rights reserved ...