VT8800/WT8800 WATER HEATER CONTROLS

69-1731

4

WARNING

Fire or Explosion Hazard.
Can cause severe injury, death or property 
damage.

Follow these warnings exactly:

1.

 To avoid dangerous accumulation of fuel gas, 

turn off gas supply at the appliance service 
valve before starting installation, and perform 
Gas Leak Test after completion of installation.

2.

 Always install a sediment trap in gas supply line 

to prevent contamination of ignition system 
control.

3.

 Follow the appliance manufacturer instructions 

if available; otherwise, use these instructions as 
a guide.

WARNING

Scalding Hazard.
Can cause burns, severe injury or death.

Always use a direct replacement sensor assembly 
when replacing upper or lower temperature 
sensor.

Location

The VT8800/WT8800 are mounted on the outside of the 
water heater tank. See Fig. 2.

Install Control to Water Tank

1.

To install the water heater control, screw the plate 
bracket into the spud until the bracket is square. 
Use a maximum torque of 50 ft. lb (two-piece 
design only).

2.

To install one-piece bracket design, screw bracket 
into the spud until the bracket is square.                     

3.

Position the valve bracket tab over the plate bracket 
slot and slide down (two piece design).

4.

Snap the valve into tabs of the valve bracket 
assembly with the inverted flare outlet facing down. 
Secure valve using one screw (two piece design).

5.

Install WT8800 control electronics on the three pins 
of the gas valve and snap into place. Secure with 
one screw.

6.

Be certain to mount the VT8800/WT8800 so that 
the gas flow is in the direction of the arrow on the 
inlet side of the control.

7.

Follow steps in Connect Gas Supply section, which 
follows.

IMPORTANT

These water heater system controls are shipped 
with protective seals over the inlet and outlet tap-
pings. Do not remove the seals until ready to 
connect the piping.

Fig. 3. Mounting the VT8800 on the water heater tank.

Connect Gas Supply

All piping must comply with local codes and ordinances or 
with the National Fuel Gas Code (ANSI Z223.1 NFPA No. 
54), whichever applies. Tubing installation must comply 
with approved standards and practices.

1.

Use new, properly reamed pipe free from chips. If 
tubing is used, make sure the ends are square, 
deburred and clean. All tubing bends must be 
smooth and without deformation.

2.

Run pipe or tubing to the water heater control. If 
tubing is used, obtain a tube-to-pipe coupling to 
connect the tubing to the control.

3.

Install a sediment trap in the supply line to the water 
heater control. See Fig. 3.

Table 3. NPT Pipe Thread Length (in.).

Pipe 

Size

Thread Pipe 

This Amount

Maximum Depth Pipe can be 

inserted into Control

1/2

3/4

1/2

M23036

GAS LINES

CONNECTED

MOUNTING

DRY SPUD

WELDED 

TO TANK

VT8800/

WT8800

69-1731.fm  Page 4  Monday, October 10, 2005  11:02 AM

Summary of Contents for VT8800

Page 1: ...tlet Mounting Mounting in upright position only Control Input Voltage Minimum 350 mV dc open circuit Voltage Maximum 850 mV dc open circuit Capacity See Table 1 Conversion Use conversion factors in Table 2 to convert capacities for other gases Regulation Range VT8800 with 1 2 in NPT inlet and 1 2 in Inverted Flare Outlet Natural Gas Minimum 30 000 Btuh Maximum 85 000 Btuh LP Gas Minimum 40 000 Btu...

Page 2: ... fail If the appliance is in a humid atmosphere make sure air circulation around the control is adequate to prevent condensation Also regularly check out the system Corrosive Chemicals Corrosive chemicals can attack the control eventually causing a failure If chemicals are used for routine cleaning avoid contact with the control Where chemicals are suspended in air as in some industrial or agricul...

Page 3: ...ained when the appliance is installed INSTALLATION When Installing This Product 1 Read these instructions carefully Failure to follow them could damage the product or cause a hazardous condition 2 Check the ratings given in the instructions and on the product to make sure the product is suitable for your application 3 Installer must be a trained experienced service technician 4 After installation ...

Page 4: ...flare outlet facing down Secure valve using one screw two piece design 5 Install WT8800 control electronics on the three pins of the gas valve and snap into place Secure with one screw 6 Be certain to mount the VT8800 WT8800 so that the gas flow is in the direction of the arrow on the inlet side of the control 7 Follow steps in Connect Gas Supply section which follows IMPORTANT These water heater ...

Page 5: ...e only ANSI approved compounds Wiring Follow the wiring instructions furnished by the appliance manufacturer if available or use the general instructions provided below When these instructions differ from the appliance manufacturer follow the appliance manufacturer instructions Make sure wiring insulation does not get cut by sharp edges NOTE All wiring must comply with applicable electrical codes ...

Page 6: ...temperature at the setpoint knob WARNING Scalding Hazard Can cause burns severe injury or death Never move setpoint knob past the Hot setting unless extremely hot water is desired Always check water temperature at the faucet and readjust until comfortably warm to the touch Consider the ages and health of all who will come in contact with heated water Perform Gas Leak Test WARNING Fire or Explosion...

Page 7: ...etermined individually for each application Some considerations are 1 Cycling frequency Appliances that may cycle 10 000 times annually should be checked monthly 2 Intermittent use Appliances that are used seasonally should be checked before shutdown and again before the next use 3 Consequence of unexpected shutdown Where the cost of an unexpected shutdown would be high the system should be checke...

Page 8: ... available Inspect thermopile connection to valve flame coverage on thermopile inspect orifice assembly for dirt check inlet pressure run open circuit thermopile output test and change thermopile if output is low 3 flashes Sensor or Valve failure Pilot On Main Valve Off Restart control If main turns on after restart replace sensor If main does not turn on after restart replace valve 4 flashes Valv...

Page 9: ...gas supply at the appliance service valve On LP systems turn off the gas supply at the gas tank Do not light any appliances in the house Do not touch electrical switches or use the phone Leave the building and use a neighbor s phone to call your gas supplier If you cannot reach your gas supplier call the fire department 2 The water heater control must be replaced in event of any physical damage ta...

Page 10: ...tructions 1 Set the temperature setpoint knob to OFF 2 Turn off the main gas valve to the appliance 3 Wait five minutes to clear out any unburned gas If you then smell gas STOP Follow step 1 in the warning above If you DO NOT smell gas continue with the next step 4 Turn on the main gas valve to the appliance 5 Replace the water heater control access panel if provided 6 Restart the appliance by per...

Page 11: ...11 69 1731 69 1731 fm Page 11 Monday October 10 2005 11 02 AM ...

Page 12: ...l Limited Honeywell Limitée 1985 Douglas Drive North 35 Dynamic Drive Golden Valley MN 55422 Scarborough Ontario M1V 4Z9 customer honeywell com U S Registered Trademark 2005 Honeywell International Inc 69 1731 S A 10 05 69 1731 fm Page 12 Monday October 10 2005 11 02 AM ...

Reviews: