Honeywell VS8521 Installation Instructions Manual Download Page 6

VS8521 VENTFREE MILLIVOLT GAS VALVE

69-1223—1

6

Checking Gas Input With Manometer

NOTE:

Both the inlet and outlet pressure taps have a 
captive screw.

1.

Be sure the gas control knob is in the OFF position.

2.

Loosen, but do not remove the outlet tap captive 
screw.

3.

Attach a plastic tube with a 1/4 in. shell ID and 
connect the manometer.

4.

Check the outlet tap pressure.

5.

Turn the gas control knob to the OFF position.

6.

Shut off the gas supply at the manual valve in the 
gas piping to the appliance or, for LP, at the tank.

7.

Loosen, but do not remove the inlet tap captive 
screw.

8.

Attach a plastic tube with a 1/4 in. shell ID and 
connect the manometer.

9.

Check the inlet tap pressure.

10.

Turn the gas control knob to the OFF position.

11.

Repeat the Gas Leak Test at the pressure tap with 
the main burner operating.

Check Safety Shutdown Performance

WARNING

Fire or Explosion Hazard.
Can cause property damage, severe injury 
or death.
Perform the safety shutdown test any time work 
is done on a gas system.

1.

Place gas control knob in PILOT position. Main 
burner should go off and pilot should remain lit.

2.

Extinguish pilot flame. The VS8521 pilot gas flow 
stops within thirty seconds. Pilot gas safety shutoff 
proves complete shutdown because the safety 
shut-off valve prohibits main burner and pilot gas 
flow.

3.

Relight pilot burner and operate the system 
through one complete cycle to ensure all controls 
operate properly.

MAINTENANCE

WARNING

Fire or Explosion Hazard.
Can cause property damage, severe injury 
or death.
Do not attempt to take apart the gas valve or 
clean it. Improper assembly and cleaning can 
cause unreliable operation.

Regular preventive maintenance is important in 
applications that place a heavy load on system controls 
such as those used in the commercial cooking and 
agricultural and industrial industries because:

In applications such as commercial cooking, the 
equipment operates 100,000 to 200,000 cycles per 
year. This heavy cycling can wear out the gas valve in 
one to two years.

Exposure to water, dirt, chemicals and heat can 
damage the gas valve and shut down the control 
system.

The maintenance program should include regular system 
checkout as outlined in the Checkout section, and 
checkout of the control system as described in the 
appliance manufacturer literature.

Maintenance frequency must be determined individually 
for each application:

Cycling frequency—Appliances that cycle 20,000 
times annually should be checked monthly.

Intermittent use—Appliances that are used seasonally 
should be checked before shutdown and again before 
the next use.

Consequence of unexpected shutdown—Where the 
cost of an unexpected shutdown would be high, the 
system should be checked more often.

Dusty, wet, or corrosive environment—Because these 
environments can cause the gas valve to deteriorate 
more rapidly, the system should be checked more 
often.

Any valve should be replaced if it does not perform 
properly on checkout or service. In addition, replace any 
module if it is wet or looks like it has ever been wet. 

Summary of Contents for VS8521

Page 1: ...2 European Community CE Certificate Applied for INSTALLATION When Installing this Product 1 Read these instructions carefully Failure to follow them could damage the product or cause a hazardous condition 2 Check the ratings given in the instructions and on the product to make sure the product is suitable for your application 3 Installer must be a trained experienced service technician 4 After ins...

Page 2: ... comply with approved standards and practices 1 Use new properly reamed pipe free from chips When tubing is used assure the ends are square deburred and clean All tubing bends must be smooth and without deformation 2 Run pipe or tubing to the valve If tubing is used obtain a tube to pipe coupling to connect the tubing to the valve 3 Install sediment trap in the supply line to the gas valve See Fig...

Page 3: ...nect power supply before making wiring connections to prevent electrical shock or equipment damage 1 Check the power supply rating on the gas valve and make sure it matches the available supply Install the transformer thermostat and other controls as required 2 This valve can be used only in a self generating system 3 Adjust the thermostat heat anticipator to the 0 1A at 750 mV rating stamped on t...

Page 4: ...lve counterclockwise to the PILOT position push the knob down and hold in position The pilot valve opens and allows gas to flow to the pilot burner 2 Push the plunger on the piezo until the pilot burner is lit Hold down the knob until a strong flame is present approximately 60 seconds 3 Release the knob The shaft will move upward and engage the safety valve lever that opens the safety valve 4 Turn...

Page 5: ...ner HI LO Manually adjusts outlet pressure NOTE Valves are shipped with the gas control knob in the ON position Perform Gas Leak Test WARNING Fire or Explosion Hazard Can cause property damage severe injury or death Stand away from the main burner while lighting Hidden gas leaks can cause flashbacks in the appliance vestibule Check for gas leaks with rich soap and water solution any time work is d...

Page 6: ...perly MAINTENANCE WARNING Fire or Explosion Hazard Can cause property damage severe injury or death Do not attempt to take apart the gas valve or clean it Improper assembly and cleaning can cause unreliable operation Regular preventive maintenance is important in applications that place a heavy load on system controls such as those used in the commercial cooking and agricultural and industrial ind...

Page 7: ...zard Can cause property damage severe injury or death Exactly follow the instructions for Pre Lighting Checks Pre Lighting Checks 1 Before lighting smell around the appliance area for gas If the appliance uses LP gas be sure to smell next to the floor because LP gas is heavier than air 2 If you smell gas immediately shut off the manual valve in the gas piping to the appliance or on LP at the tank ...

Page 8: ...C Thermocouple Have thermostat contacts open and pilot lit with Pilotstat knob turned to PILOT Reading should be a minimum of 12 mV in a new ODS pilot burner assembly If the reading is less than 12 mV replace the ODS pilot burner assembly The power unit will hold in down to 3 mV If the output of the thermocouple is less than 3 mV replace the ODS pilot burner assembly 4 Test D Operator Pull In have...

Reviews: