INSTRUCTION SHEET

GAS CONTROL WITH INTEGRATED 1:1 GAS/AIR REGULATOR FOR

AUTOMATIC IGNITION SYSTEMS

VR4611VA1007

EN1R--9170 0109R1--NE

APPLICATION

VR4611VA 1007 gas control has been specially developed for

application in domestic premix appliances with intermittent

pilot ignition.
VR4611VA 1007 gas control is used in a system context in

conjunction with fan control, an intermittent pilot ignition (IP)

control module and associated devices to provide

programmed safe light--up and supervision of the main burner

of an appliance.
VR4611VA 1007 gas control is intended to be used for natural

gas and LP gas.
VR4611VA 1007 gas control is approved in accordance with

existing european standards.

DESCRIPTION

VR4611VA 1007 gas control performs all the functions

required to safely regulate gas flow to the main burner of

domestic central heating equipment, warm air furnaces, back

boilers and water heaters.
VR4611VA 1007. gas control consists of a first direct electric

ON/OFF operator for opening the safety valve of class B

according to EN 161 and a second electric ON/OFF servo

operator valve for opening the main valve of class C and J

according to EN 161.

SPECIFICATIONS

Model

VR4611VA 1007: line voltage, fast opening, with

integrated 1 : 1 gas/air regulation, low capacity, and

with two automatic shut off valves for intermittent

pilot ignition (IP) applications.

Dimensions

See fig. 1.

Ambient temperature

0 ... 70

_

C

Pressure regulation function

Class C according to EN 88

Pipe size

Pipe connections are designed to meet the bending stress of

group 2 according to EN 161.

Inlet and outlet:

1

/

2

” ISO 7--1 internal parallel pipe thread.

Inlet and outlet can also be made with straight or elbow

flanges.

Air pressure connection

Servo pressure regulator has an M5 threaded hole to make

connection between regulator and appliance.

Maximum air pressure

8 mbar without outlet gas pressure (before ignition)

20 mbar with outlet gas pressure present (after ignition)

Minimum regulation capacity

0.5 m

3

air/

h

at

,

p=0.5 mbar across the main burner injector

and

30 mbar

maximum operating pressure.

0.7 m

3

air/

h

at

,

p=0.5 mbar across the main burner injector

and

60 mbar

maximum operating pressure.

Minimum operating gas pressure

15 mbar

Offset range

-- 0.4 mbar ... + 0.2 mbar

gas control in 90

_

from upright position (first coil horizontal)

-- 0.25 mbar ... + 0.2 mbar

gas control in upright position (first coil vertical)

Maximum operating gas pressure

The P

max

60 mbar indication on the housing is the maximum

inlet pressure at which the gas control functions safely.

Capacity (measured with throttle open,1013 mbar and 15

_

_

_

_

C)

4.2 m

3

/h air at

,

p = 10 mbar.

Curve is available on request.

Subj

ect

to

change

wi

thout

not

ic

e.

Pr

in

te

d

in

the

Net

her

lands.

Summary of Contents for VR4611VA1007

Page 1: ...lation low capacity and with two automatic shut off valves for intermittent pilot ignition IP applications Dimensions See fig 1 Ambient temperature 0 70 _C Pressure regulation function Class C according to EN 88 Pipe size Pipe connections are designed to meet the bending stress of group 2 according to EN 161 Inlet and outlet 1 2 ISO 7 1 internal parallel pipe thread Inlet and outlet can also be ma...

Page 2: ... Electrical data Power consumption at 220 240 V 1st operator 3 6 4 7 W 2nd operator 3 4 4 5 W Current at 220 240 V 1st operator 32 36 mA 2nd operator 20 4 24 mA A Cap screw offset adjustment screw B 6 3 AMP terminals C Inlet pressure tap D Throttle adjustment screw E Outlet pressure tap F Pilot outlet connection G M5 air pressure connection 36 M 5 5 1 2 d 127 21 118 d 30 1 2 ISO 7 1 d 36 3 4 ISO 7...

Page 3: ...in intermittent ignition IP system The appliance manufacturer s instructions should always be followed Perform gas leak test WARNING FIRE OR EXPLOSION HAZARD CAN CAUSE PROPERTY DAMAGE SEVERE INJURY OR DEADTH Check for gas leaks with a rich soap and water solu tion any time work is done on a gas control Gas leak test Paint all pipe connections upstream of the gas control with with a rich soap and w...

Page 4: ...nce Please contact your Honeywell representative if the maximum of 10 is exceeded Oscillation outlet pressure to be recorded with oscilloscope etc via transducer without damping CHECKOUT Final checkout of the installation After any adjustment check pressure taps and gas connections with an approved leak detection fluid for gas leakage After installation and any adjustment start the appliance and o...

Reviews: