VP512A Unit 

Ventilator Valve 

INSTALLATION INSTRUCTIONS 

BEFORE INSTALLING 

When installing the valve, allow space for the actuator 

removal and service. See Fig. 1 and 2. Refer to Table 1. 

Do not install upside down. Moisture, or dust and dirt, 
might collect in underside of the actuator causing 

damage and can impair valve operation. 

It can be necessary, due to space limitations, to remove 
the actuator before installing the valve body. Follow the 

procedures shown in Fig. 3. Reverse this procedure to 
replace the actuator. 

Refer to form 77-2301 (General Engineering Data for 

Pneumatic Control of Steam and Water Unit Ventilators) 
for the location of the VP512A in individual unit 

ventilators. 

INSTALLATION 

1.

  

Install the valve as shown in Fig. 1. 

IMPORTANT: 

The valve must be installed with the arrow on 
the body pointing in the direction of the fluid 

flow. 

2.

  

If necessary, rotate the actuator for control air tub-
ing installation by loosening the two set screws 

shown in Fig. 3. 

3.

  

Tighten the set screws after the actuator is posi-

tioned. 

CONTROL AIR LINE 

FLUID FLOW 

ARROW EMBOSSED 
ON VALVE BODY 

M18803 

Fig. 1. Valve installation (straight-through 

pattern shown). 

Table 1. VP512A Approximate Dimensions in in. (mm). 

Valve 

Size 

Body 

Type 

1/2 

Straight  1-1/4 (32) 

√ 

1-7/8 (48)  2-5/8 (67)  1-3/4 (44)  √ 

1-13/16 (46) 4-11/32 

(110) 

√ 

Angle 

1-1/4 (32) 

2 (51) 

√ 

2-5/8 (67)  √ 

3/4 (19) 

1-13/16 (46) √ 

1-3/4 (44) 

3/4 

Straight  1-1/4 (32) 

√ 

2 (51) 

2-1/8 (54)  1-3/4 (44)  √ 

1-13/16 (46) 4-11/32 

(110) 

√ 

Angle 

1-1/4 (32) 

2-1/8 (54)  √ 

2-1/8 (54)  √ 

7/8 (22) 

1-13/16 (46) √ 

1-3/4 (44) 

Straight  1-3/8 (35) 

√ 

2-1/4 (57)  3 (76) 

1-5/8 (41)  √ 

1-31/32 (50) 4-1/2 (114)  √ 

Angle 

1-3/8 (35) 

2-1/8 (54)  √ 

3 (76) 

√ 

1-1/16 (27)  1-31/32 (50) √ 

1-29/32 

(48) 

1-1/4  Straight  1-9/16 (40)  √ 

2-1/2 (64)  3-3/4 (95)  1-1/2 (38)  √ 

2-9/16 (65)  4-13/16 

(122) 

√ 

Angle 

1-9/16 (40)  2-1/8 (54)  √ 

3-3/4 (95)  √ 

1-3/16 (30)  2-9/16 (65)  √ 

2-15/32 

(63) 

1-1/2  Straight  1-11/16 (43)  √ 

2-7/8 (73)  4-1/4 (108)  1-3/8 (35)  √ 

3-9/32 (83)  5-5/32 (131) √ 

Angle 

1-11/16 (43)  2-1/8 (54)  √ 

4-1/4 (108)  √ 

1-3/8 (35) 

3-9/32 (83)  √ 

2-15/16 
(75) 

® U.S. Registered Trademark 
Copyright © 2002 Honeywell •   All Rights Reserved 

95-1785EF 

Summary of Contents for VP512A

Page 1: ...ol air tub ing installation by loosening the two set screws shown in Fig 3 3 Tighten the set screws after the actuator is posi tioned CONTROL AIR LINE FLUID FLOW ARROW EMBOSSED ON VALVE BODY M18803 Fig 1 Valve installation straight through pattern shown Table 1 VP512A Approximate Dimensions in in mm Valve Size Body Type A B C D E F G H J 1 2 Straight 1 1 4 32 1 7 8 48 2 5 8 67 1 3 4 44 1 13 16 46 ...

Page 2: ...WS 2 ADJUSTMENT 4 LIFT ACTUATOR NUT FROM BONNET M18804 Fig 3 Actuator removal when necessary CHECKOUT AND TESTING With a 0 to 30 lb in2 0 to 205 kPa gage in the branch line vary branch line pressure The difference between the pressure at which the stem begins to move and the pressure at full close off indicates the operating range The valve begins to close at 3 or 6 lb in2 21 or 40 kPa and is full...

Page 3: ... débit du fluide 2 Pour l installation de la canalisation d air de com mande tourner s il y a lieu l actionneur en desser rant les deux vis de réglage illustrées à la Fig 3 3 Une fois l actionneur monté serrer les vis de réglage CANALISATION D AIR DE COMMANDE DÉBIT DU FLUIDE FLÈCHE GRAVÉE SUR LE CORPS DE VANNE MF18803 Fig 1 Installation de la vanne modèle à corps droit illustré Tableau 1 Encombrem...

Page 4: ...r et la pression lorsque la vanne se 3 DESSERRER LES VIS DE ferme complètement représente la gamme de fonctionnement La vanne commence à se fermer à 21 ÉCROU DE RÉGLAGE RÉGLAGE 2 4 DÉGAGER L ACTIONNEUR ou 40 kPa 3 à 6 lb poÚ et elle est complètement fermée à 5 ou 76 kPa 8 ou 11 lb poÚ selon l application DU BONNET MF18804 Fig 3 Démontage de l actionneur si nécessaire Imprimé aux États Unis sur du ...

Reviews: