Honeywell VK41 V Series Instruction Sheet Download Page 4

EN1R-9134 0503R20-NE

4

Mounting of rectifier plug

See fig. 2.

Mounting screw of rectifier plug

Torque: 40 Ncm max.

Fig. 3. Coil connection

Current and power consumption at nominal voltage

INSTALLATION

IMPORTANT

Take care that installer is a trained experienced 
service person.
Turn off gas supply before starting installation.
Disconnect power supply to prevent electrical shock 
and/or equipment damage.
Do not remove seals over inlet and outlet until the 
device is ready to be installed.
If M5 air pressure connection is not to be used, it is 
recommanded to push a dust cap  into the hole.

Mounting position

The gas control can be mounted 0 to 90

°

 in any direction 

from the upright position, i.e. from the position when electric 
coils are on top.

Main gas connection

Gas controls with internal thread

Take care that dirt cannot enter the gas control during 
handling.

Use a sound taper fitting with thread according to ISO 7-1 
or a piece of new, properly reamed pipe, free from swarf.

Do not thread or tighten the pipe or pipe fitting too far (see 
table below). Otherwise distortion and malfunction could 
result.

Apply a moderate amount of good quality thread 
compound to the pipe or fitting only, leaving the two end 
threads bare.If permitted by local safety regulations PTFE 
tape may be used as an alternative.

Tighten gas control using the right open end wrench. 
See fig. 4.

Fig. 4. 

Ensure the gas flows in the same direction as the arrow 
on the bottom of the gas control.

Gas controls for flange connection

Insert ”O”-ring in the groove of each flange. If necessary 
grease ”O”-ring slightly to keep it in place.

Mount gas control between flanges using the four screws 
for each flange.

Voltage

Current (mA)

Power 
consumption (W)

220 V, 50/60 Hz

48

9.4

240 V, 50/60 Hz

52

11.2

110 V, 50/60 Hz

89

8.8

24 V, 50/60 Hz

424

9.2

Pin number

5

4

3

2

1

Pipe size (inch)

Max. length of pipe thread (mm)

3

/

8

14

1

/

2

18.6

Summary of Contents for VK41 V Series

Page 1: ...ure regulator is in accordance with class B requirement of EN 88 VK41 V VK81 V gas controls can handle the three gas families manufactured gas natural gas and LP gas VK41 VB VK81 VB gas controls can handle second family gas only SPECIFICATIONS Models VK41 0 series line voltage gas control with pilot burner connection two automatic shut off valves and pilot burner connection for direct spark igniti...

Page 2: ... operating pressure maximum Minimum operating gas pressure 15 mbar Maximum operating gas pressure 60 mbar VK411x VK811x Class B C 30 mbar VK412x VK812x Class B B 30 mbar VK41xxVB VK81xxVB Class B C The Pmax 60 mbar indication on the housing is the maximum inlet pressure at which the gas control functions safely Maximum air pressure 8 mbar without outlet gas pressure before ignition 20 mbar with ou...

Page 3: ...Vac or 220 240 Vac output by using a rectifier plug 45 900 441 Fig 2 Mounting of rectifier plug IMPORTANT Warranty claims are not accepted if not the specified plug rectifier circuit is used Electical protection of gas control with rectifier plug IP 40 Inlet End outlet Side outlet Body length mm Flanged Flanged 105 Flanged Flanged 105 Internal 3 8 ISO 7 1 Flanged 115 Internal 1 2 ISO 7 1 Flanged 1...

Page 4: ...ntrol during handling Use a sound taper fitting with thread according to ISO 7 1 or a piece of new properly reamed pipe free from swarf Do not thread or tighten the pipe or pipe fitting too far see table below Otherwise distortion and malfunction could result Apply a moderate amount of good quality thread compound to the pipe or fitting only leaving the two end threads bare If permitted by local s...

Page 5: ... off end of tubing and remove burrs Fig 6 External thread connection with nut and olive q q q q With 3 4 nut and O ring see fig 7 Pipe diameter 15 mm Nut drawing 45 006 583 003 O ring size 14 3 x 2 4 mm drawing 45 001 528 048 Fastening torque maximum 50 Nm minimum 10 Nm Pipe end construction see fig 10 Fig 7 External thread connection with nut and O ring r r r r With 3 4 nut and flat sealing ring ...

Page 6: ...ectrical connections IMPORTANT Disconnect power supply to prevent electrical shock and or equipment damage Wiring must be in accordance with local regulations The appliance manufacturer s instructions should always be followed Before installing or replacing any control check that type number is correct for the application Ensure combustion chamber is free of gas before start up Conduct a thorough ...

Page 7: ...tment screw Check gas supply pressure to the appliance using a pressure gauge connected to the inlet pressure tap Start fan and check air flow Energize both electric operators in order to have gas input to burner and ignite boiler Adjust CO2 at the desired value at low output with offset adjustment screw Turn offset adjustment screw clockwise to increase CO2 Operate boiler on high output Only modu...

Page 8: ...9134 0503R20 NE 8 Home and Building Control Combustion Control Center Europe Honeywell BV Phileas Foggstraat 7 7821 AJ Emmen The Netherlands Tel 31 591 695911 Fax 31 591 695200 http europe hbc honeywell com ...

Reviews: