Honeywell VE4000 Series Instruction Sheet Download Page 3

 

Honeywell 

ISTR0018  1602RA-NE 

TECHNICAL 

SPECIFICATIONS 

 

VE series solenoid gas valves 

VExx10 (DN 10) 
VExx15 (DN 15) 
VExx20 (DN 20) 
VExx25 (DN 25) 
VExx32 (DN 32) 
VExx40 (DN 40) 
VExx50 (DN 50) 
VExx65 (DN 65) 
VExx80 (DN 80) 
VEx100 (DN 100) 
 

VE series suitable for fluid power actuators 

VE5065 (DN 65) 
VE5080 (DN 80) 
VE5100 (DN 100) 
 

Pipe sizes 1000/2000 series 

Inlet and outlet G3/8" up to G21/2" internal parallel pipe 
thread according ISO 7-1 
 

Pipe sizes 3000/4000 series 

Flanged connection DN 65, DN 80 and DN100 according to 
DN 16 UNI 2223. 
 

Torsion and bending stress 

Pipe connections meet Group 2 according EN 161 
requirements. 
 

Ambient temperature 

-15 °C ... 60 °C 
 

Supply voltage 

24 V, 50/60 Hz 1)* 
100-120 V, 50/60 Hz 
200-240 V, 50/60 Hz 
The applicable voltage is led to the solenoid coil via a 
rectified circuit. 
1): only for DN10 up to DN50  
 
Operational voltage range 
The gas valve will function between 85% and 110% of the 
rated voltage 
 

Electrical connection VE4xxx/VE6xxx/VE8xxx

 

Option 1: Wiring on terminal block on circuit cables entering 
box via PG Cable Gland 
Option 2: Connection by means of DIN plug on DIN faced 
connection located on front cover according to 
ISO4400 / DIN EN 175301-803 
 

Electrical connection VE5xxx series 

See product literature fluid power actuators 
 
 

Enclosure VE4xxx/VE6xxx/ VE8xxx 

IP 65 when using supplied PG gland and cable  
diameter 7 – 13 mm for PG version or using suitable DIN 
plug with gasket. 
 

 

Capacity 

See page 7 and 8 
 

Maximum operating pressure

Inlet 

Maximum operating pressure (mbar) 

VE4010/VE6010 
VE8010 

200 or 500 
200 

VE4015/VE6015 
VE8015 

200 or 500 
200 

VE4020/VE6020 
VE8020 

200 or 500 
200 

VE4025/VE6025 
VE8025 

200 or 500 
200 

VE4032/VE6032 
VE8032 

200 or 500 
200 

VE4040/VE6040 
VE8040 

200 or 500 
200 

VE4050/VE6050 
VE8050 

200 or 500 
200 

VE4065/VE6065 
VE8065 
VE5065 

200 or 500 
200 
200 or 360 

VE4080/VE6080 
VE8080 
VE5080 

200 or 500 
200 
200 or 360 

VE4100/VE6100 
VE5100 

200 or 500 
200 or 500 

 
 

Summary of Contents for VE4000 Series

Page 1: ...e housing The VExxxxX3xxx and VE5xxxX3xxx series gas valves are equipped at both sides with mounting holes to adapt a pilot solenoid valve combination to allow either internal or external pilot gas Furthermore these valves are equipped with two M6 mounting holes to adapt an A4020A electronic leak test The VExxxxB series gas valves have an adjustable flow rate regulator on top of the coil For the V...

Page 2: ...egulated ON OFF VExxxxAxxxx Standard Standard Flow regulator VExxxxBxxxx Optional Optional 2 Adjustable opening and flow regulator VExxxxCxxxx Optional 1 Not available Motorized opening ON OFF VE5xxxAxxxx Not available VE5065A3xxx VE5085A3xxx Motorized opening characterized VE5xxxCxxxx Not available VE5065C3xxx VE5085C3xxx Safety relief valve ON OFF Normally Open with or without position indicatio...

Page 3: ...alve will function between 85 and 110 of the rated voltage Electrical connection VE4xxx VE6xxx VE8xxx Option 1 Wiring on terminal block on circuit cables entering box via PG Cable Gland Option 2 Connection by means of DIN plug on DIN faced connection located on front cover according to ISO4400 DIN EN 175301 803 Electrical connection VE5xxx series See product literature fluid power actuators Enclos...

Page 4: ...2 723 125 180 POWER CONSUMPTION Version S 200 mbar Model number 12 Volt 50 60Hz nominal 12 Volt 50 60Hz 110 of nominal 24Volt 50 60Hz nominal 24 Volt 50 60Hz 110 of nominal 24 Volt dc nominala b 24 Volt dc 110 of nominal 110 Volt 50 60Hz nominal 110 Volt 50 60Hz 110 of nominal 220 Volt 50 60Hz nominal 220 Volt 50 60Hz 110 of nominal VExx20S 16 19 17 21 14 17 16 19 POWER CONSUMPTION Version S 360 m...

Page 5: ...n alternative In order to tighten the pipe in the valve do not use the actuator as a lever but use a suitable wrench operating on the wrench bosses Main gas connection flanged valves Take care that dirt cannot enter the gas valve during handling Ensure the gas flows in the same direction as the arrow on the housing of the gas valve Ensure that inlet and outlet flanges are in line and separated fro...

Page 6: ...the box and tightened as shown in Fig 2 Specified torque for the nut 4 Nm Mounted PG gland shown in Fig 3 Specified torque PG gland 3 Nm Fig 2 Fig 3 After connecting wires L N PE to dedicated connectors on connector block the connection needs to closed by mounting the front cover Before placing the cover please check the correct position of seal as shown in Fig 4 The cover can only be mounted in o...

Page 7: ... in the slot of adjustment screw which is situated in center of the valve Turn screw driver counter clockwise to increase or clockwise to decrease step pressure Replace cap on top of the coil Step pressure adjustment Fig 8 Opening speed adjustment Remove the cap from top of the coil by loosening both screws Place screw driver in the slot of adjustment screw which is of center line Turn screw drive...

Page 8: ... 200 240 DIN BB0xxxxx VExx20 VExx25 24 PG BB0xxxxx 100 120 PG BB0xxxxx 200 240 PG BB0xxxxx VExx20 VExx25 24 DIN BB0xxxxx 100 120 DIN BB0xxxxx 200 240 DIN BB0xxxxx VExx32 VExx40 24 PG BB0xxxxx 100 120 PG BB0xxxxx 200 240 PG BB0xxxxx VExx32 VExx40 24 DIN BB0xxxxx 100 120 DIN BB0xxxxx 200 240 DIN BB0xxxxx Valve type Voltage Connection Ordering number VExx50 24 PG BB0xxxxx 100 120 PG BB0xxxxx 200 240 ...

Reviews: