Honeywell V4073A Manual Download Page 1

H

E

A

T

IN

G
C

O

N

T

R

O

L

S

4.21

V4073A

MOTORISED MID-POSITION DIVERTER VALVE

FEATURES

Spring return action

Three position operation

Powerhead replaceable without

draining down

Manual lever for filling/draining down

Quiet operation, minimal power

consumption

Provides electrical output to

boiler and/or pump

OPTIONS

22mm/28mm or

3

/

4

"/ 1" connections

Replacement motor

Replacement powerhead

Replacement ball and

‘O’ ring kit

APPLICATION

The V4073A Valve has been designed to control the flow of water

in domestic central heating systems, where both radiator and hot

water cylinder circuits are pumped. It is typically suited for small

to medium sized installations.

The V4073A Mid-position Diverter Valve should be used in

conjunction with a room thermostat and cylinder thermostat to

provide full temperature control of a conventional, fully pumped

central heating installation. When used in this way, the control

system is known as Sundial Y Plan and the components can be

connected together using the Sundial Plan Wiring Centre which

has dedicated terminations and there is no need for a wiring

diagram.

An alternative method of wiring is to use the Honeywell 10-way

Junction Box (42002116-001) together with the Honeywell

Sundial Plans Wiring Booklet.

© Honeywell Control Products and Systems, Issue 10

0014_Section 4_dft10_v4.qxd:Section 2_dft9

15/10/07  16:20  Page 43