UC100C ULTRAVIOLET AIR TREATMENT SYSTEM REPLACEMENT LAMP

$XWRPDWLRQDQG&RQWURO6ROXWLRQV

+RQH\ZHOO

+RQH\ZHOO/RQH\ZHOO/LPLWpH

'RXJODV'ULYH1RUWK

'\QDPLF'ULYH

*ROGHQ9DOOH\01

6FDUERURXJK2QWDULR

09=

Printed in U.S.A. on recycled 
paper containing at least 10% 
post-consumer paper fibers.

MERCURY NOTICE

This device contains mercury in the sealed ultraviolet 

lamp(s). Do not place your used lamp(s) in the trash. 
Dispose of properly.

Broken Lamp Cleanup

.

Do not use a household vacuum.

Sweep debris into a plastic bag and dispose of 

properly.

Contact your local waste management authority for 

instructions regarding recycling and the proper 
disposal of old lamp(s). 

Replacing Your Lamps (Annually)

Annual replacement of your lamps is required. To replace your 

lamps:

1.

Obtain the correct replacement lamp for your unit. See 

Table 1.

2.

Disconnect the power to your HVAC system.

3.

Open the enclosure door.

4.

Disconnect the lamp cable from the electrical subpanel. 

Allow the lamp to cool for at least 15 minutes.

5.

Rotate the lamp knob until the tabs align with the slots; 

then carefully remove the lamp; be careful not to strike 

or hit the lamp glass on the enclosure edges.

6.

Carefully insert the new lamp assembly into the     

enclosure. Avoid striking the lamp glass against the hole 

edges or other object to prevent damage or breakage. If 

necessary, use a clean, dry cloth to help guide the lamp 

assembly during installation. 

Do not touch the lamp   

surface with your hands; use only a soft cloth.

7.

Align the tabs on the lamp knob with the slots in the 

lamp receptacles and turn lamp clockwise until it stops.

8.

Connect the lamp assembly cord conector to the mating 

receptacle located on the exterior of the electrical     

sub-compartment.

9.

Verify that the connector is fully inserted into the    

receptacle.

WARNING

UV Light Hazard. 

Harmful to bare skin and eyes. 

Can cause temporary or permanent loss of vision.

Never look at the lamps while illuminated.

Only view illumination by way of the light indicator 

located on the lamp knob.

10.

Reconnect the power to the HVAC system.

11.

Verify that your ultraviolet lamp(s) are operating 

only by 

viewing through

 

the lamp light indicator

 on the lamp 

knob.

 Never look directly at your lamp(s) while 

illuminated

.

Table 1.  Replacing Your Lamp(s).

Unit Description

Replacement Lamps

Wattage

UV100C3002 Ultraviolet Air Treatment System (Light 

Commercial model)

UC100C3007

36W

Reviews: