Terminal Description
*
NOTE:
The outer screws on the terminal block
secure the block to the chassis. They are not used
for wiring.
A wiring terminal block is located on the side panel
of the TrueDRY unit.
The six terminals for the terminal block (reading from
left to right in the photo) are:
FLOAT: External low voltage float switch or water
sensor (two terminals). Use normally
closed switch.
DHUM: Compressor and fan operation for
dehumidification
R: DR90-AP 24V output
FAN: Fan activation only for ventilation
C: DR90-AP 24V output
External 24V devices can be powered from R and C
terminals (20VA max.).
CAUTION: Low voltage hazard.
Can cause equipment damage.
Disconnect HVAC equipment before beginning installation
.