TABLE 1—THERMOSTAT MODELS AND APPLICATIONS.

Heat

Model

Switching

Anticipator

See

Number

Application

System

Fan

Range

Comments

Fig.

T834C1137

For use in standard

HEAT-OFF-

ON-AUTO

0.18 to 1.0A

TRADELINE; Beige.

3

heating-cooling

COOL

systems.

T834C1541

For use in gas- or

SUPER TRADELINE;

4

oil-fired, or central

Beige.

electric heat

a

 systems.

T834C2267

For use in gas- or

SUPER TRADELINE;

5

oil-fired, single-stage

Premier White.

heat pump or central

(Jumper included.)

electric heat

a

 systems.

T834C2309

For use in standard

0.3 to 1.2A

TRADELINE; Beige.

3

heating-cooling
systems.

a

In electric heat applications without fan sequencers, jumper terminals 1 and 2 to control the fan from the thermostat during
heating.

tion.

3. Installer must be a trained, experienced service tech-

nician.

4. After installation is complete, check out product op-

eration as provided in these Instructions.

CAUTION

Disconnect power supply before beginning instal-
lation to prevent electrical shock or equipment
damage.

Contact your local waste management authority for in-

structions regarding recycling and the proper disposal of this
control, or of an old control containing mercury in a sealed
tube.

If you have questions, call Honeywell Inc. at 1-800-468-

1502.

 J. H.  •  Rev. 2-93  •         •  ©Honeywell Inc. 1993 •  Form Number 69-0434—5

T834C

Heating-Cooling Thermostat

TRADELINE

Application

T834C Thermostats control 24 to 30 Vac single-stage heating-cooling systems. See Table 1 for specific models and

applications. An spdt mercury switch makes R to W on a temperature fall for heating, and R to Y on a temperature rise for cooling.
See Fig. 1.

Recycling Notice

This control contains mercury in a sealed tube. Do not

place control in the trash at the end of its useful life.

If this control is replacing a control that contains mercury

in a sealed tube, do not  place your old control in
the trash.

M3375

M3375

Installation

WHEN INSTALLING THIS PRODUCT...

1. Read these instructions carefully. Failure to follow

them could damage the product or cause a hazardous condi-
tion.

2. Check the ratings given in the Instructions and on the

product to make sure the product is suitable for your applica-

Fig. 1—Internal view of T834C.

Summary of Contents for TRADELINE T834C1137

Page 1: ... equipment damage Contact your local waste management authority for in structions regarding recycling and the proper disposal of this control or of an old control containing mercury in a sealed tube If you have questions call Honeywell Inc at 1 800 468 1502 J H Rev 2 93 Honeywell Inc 1993 Form Number 69 0434 5 T834C Heating CoolingThermostat TRADELINE Application T834C Thermostats control 24 to 30...

Page 2: ...ble heat anticipator indicator to match the current draw of the primary heating control or as recom mended by the equipment manufacturer see Heat Anticipa tor Setting 4 Connect the wires to the terminals on the back of the thermostat See Figs 3 5 for internal schematic and typical hookup diagrams If using electric heat compatible thermo stat in central electric heat applications jumper terminals 1...

Page 3: ... O 2 G R 1 2 CHANGEOVER RELAY COOL 3 4 4 Fig 4 Internal schematic and typical hookup for T834C1541 in gas or oil fired or central electric heat system Fig 5 Internal schematic and typical hookup for T834C2267 in gas or oil fired single stage heat pump or central electric heat system M2690 POWER SUPPLY PROVIDE DISCONNECT MEANS AND OVERLOAD PROTECTION AS REQUIRED IN ELECTRIC HEAT OR SINGLE STAGE HEA...

Page 4: ...emperature setting lever so mercury bulb is in horizontal position See Fig 1 10 Carefully replace thermostat cover IMPORTANT Anincorrectlyleveledthermostatwillcause the temperature control to deviate from setpoint Setting andAdjustment TEMPERATURE SETTING Push the temperature setting lever to the desired control point on the temperature scale The same lever controls both heating and cooling SYSTEM...

Page 5: ...stat last turned the compressor off or from when the system first received power This delay protects the compressor WiththesystemswitchsetatCOOLandthefanswitch set at AUTO move the temperature setting lever about 10 F 6 C belowroomtemperature Coolingandfanshould start see NOTE above Move the temperature setting lever about10 F 6 C aboveroomtemperature Coolingandfan should shut off FAN With the sys...

Page 6: ...Automation and Control Solutions Honeywell Internationals Inc Honeywell Limited Honeywell Limitée 1985 Douglas Drive North 35 Dynamic Drive Golden Valley Minnesota 55422 Scarborough Ontario M1V 4Z9 ...

Reviews: