To use this mode, press the 

 button until 

MAN

 is

selected (outlined) on the screen. Then, set the desired

temperature using the 

 buttons.

In this mode, any modification to the temperature
setpoint must be done manually.

To use the economy mode, press the 

 button until

ECONO

 is selected (outlined) on the screen. This

mode is ideal for weekend residences as it can be
used as follows: The temperature is kept at an
economy level during most of your absence and is
raised to a comfortable level by your usual arrival. If
you do not show up, the temperature returns to the
economy level until next weekend.

The economy mode has two periods which should be set as follows:

The economy mode should be used as follows:

Place the thermostat in economy mode during your absence.

When you arrive, place the thermostat in automatic mode or in
manual mode before the temperature drops back to the
economy level.

When you leave, switch the thermostat back to economy mode.

To program the two periods of the economy mode:

n

Press the 

 button until 

ECONO

 is selected.

o

Press the 

 button. Period 1 is displayed.

p

Set the start day for the period using the 

 button.

q

Set the start time using the 

 and 

 buttons.

r

Set the temperature for the period using the 

 buttons.

s

Press 

 to select period 2.

t

Repeat steps 3 to 5 to set the day, time and temperature for 
period 2.

u

Press 

 

to return the thermostat to normal display.

During a power outage, the thermostat display remains lit for
approximately the first 15 minutes during which the 

LP

 (low power)

indicator appears. The settings are saved in memory. However, if the
power failure exceeds 5 hours, only the thermostat’s clock must be 
re-adjusted. When power returns, the thermostat returns to the mode
of operation preceding the power outage.

Supply

: 240 VAC, 50/60 Hz

Minimum load

: 500 W (2 A resistive only)

Maximum load

: 3000 W (12.5 A resistive only)

Display range

: 0°C to 70°C (32°F to 99°F)

Setpoint range

: 5°C to 27°C (40°F to 80°F)

Resolution

: 1°C (1°F)

Storage

: -20°C to 50°C (-4°F to 120°F)

Dimensions

: 126 x 121 x 33 mm (5.0 x 4.8 x 1.3 inches)

Approval

: c UL us

Honeywell warrants this product, excluding battery, to be free from defects in the
workmanship or materials, under normal use and service, for a period of five (5) years
from the date of purchase by the consumer. If at any time during the warranty period the
product is determined to be defective or malfunctions, Honeywell shall repair or replace it
(at Honeywell's option).
If the product is defective,
(i)

return it, with a bill of sale or other dated proof of purchase, to the place from which
you purchased it, or 

(ii)

call Honeywell Customer Care at 1-800-468-1502. Customer Care will make the
determination whether the product should be returned to the following address:
Honeywell Return Goods, Dock 4 MN10-3860, 1885 Douglas Dr N, Golden Valley,
MN 55422, or whether a replacement product can be sent to you.

This warranty does not cover removal or reinstallation costs. This warranty shall not
apply if it is shown by Honeywell that the defect or malfunction was caused by damage
which occurred while the product was in the possession of a consumer.
Honeywell's sole responsibility shall be to repair or replace the product within the terms
stated above. HONEYWELL SHALL NOT BE LIABLE FOR ANY LOSS OR DAMAGE OF
ANY KIND, INCLUDING ANY INCIDENTAL OR CONSEQUENTIAL DAMAGES
RESULTING, DIRECTLY OR INDIRECTLY, FROM ANY BREACH OF ANY WARRANTY,
EXPRESS OR IMPLIED, OR ANY OTHER FAILURE OF THIS PRODUCT. Some states
do not allow the exclusion or limitation of incidental or consequential damages, so this
limitation may not apply to you.
THIS WARRANTY IS THE ONLY EXPRESS WARRANTY HONEYWELL MAKES ON
THIS PRODUCT. THE DURATION OF ANY IMPLIED WARRANTIES, INCLUDING THE
WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR
PURPOSE, IS HEREBY LIMITED TO THE FIVE-YEAR DURATION OF THIS
WARRANTY. Some states do not allow limitations on how long an implied warranty lasts,
so the above limitation may not apply to you.
This warranty gives you specific legal rights, and you may have other rights which vary
from state to state.
If you have any questions concerning this warranty, please write Honeywell Customer
Relations, 1985 Douglas Dr, Golden Valley, MN 55422 or call 1-800-468-1502. In
Canada, write Retail Products ON15-02H, Honeywell Limited/Honeywell Limitée, 35
Dynamic Drive, Scarborough, Ontario M1V4Z9.

I

f you have any questions about the operation of your thermostat, please go to 

http://

yourhome.honeywell.com

, or call Honeywell Customer Care toll-free at 

1-800-468-

1502

.

q

Manual (hold) mode

4.

r

Economy mode

5.

Period Temperature Setting

Start Time Setting

1

Set to a comfortable 
level.

Set a time where the temperature 
starts to rise to reach a comforta-
ble level by the time you arrive.

2

Set to an economy 
level.

Set a time where the temperature 
starts to drop to an economy level 
if you do not show up.

s

Power Outage

6.

t

Troubleshooting

7.

PROBLEM

SOLUTIONS

Thermostat is hot.

Under normal operation, the thermostat housing 
may reach a temperature between 35°C (95°F)  
and 40°C (104°F).

Wrong temperature is dis-
played.

Verify that the sticker on the thermostat’s screen 
has been removed. If the thermostat is exposed to 
air draft, eliminate the draft. 

Wrong time is displayed.

The thermostat was probably without power for 
more than 5 hours.

Temperature does not change 
according to the programmed 
schedule.

Check that the thermostat is in automatic mode. 
Check the schedule and clock settings.

The normal display disappears 
and reappears after a few min-
utes.

The thermal protection device on the heater might 
be open. This can happen if the heater is 
obstructed by furniture or curtains and has over-
heated.

u

Specifications

8.

;

Warranty

9.

Customer Assistance

10.

As an E

NERGY

 S

TAR

®

 partner, Honeywell has 

determined that this product meets the E

NERGY

 S

TAR

 

guidelines for energy efficiency.

Summary of Contents for TL6120

Page 1: ... left to right p Set the start time for the period using the and buttons NOTE To disactivate the period press the button Instead of displaying the start time of the period the thermostat will dis play During operation the thermostat will skip over that period q Set the temperature for the period using the buttons r Repeat steps 2 to 4 for the remaining periods s Press the button to return the ther...

Page 2: ...y MN 55422 or whether a replacement product can be sent to you This warranty does not cover removal or reinstallation costs This warranty shall not apply if it is shown by Honeywell that the defect or malfunction was caused by damage which occurred while the product was in the possession of a consumer Honeywell s sole responsibility shall be to repair or replace the product within the terms stated...

Page 3: ...droite p Régler l heure du début de la période affichée à partir des boutons et NOTA Pour désactiver la période appuyer sur le bouton Au lieu d afficher le début de la période le thermostat affichera Durant son fonctionnement le thermostat sautera cette période q Régler la température pour la période affichée à partir des boutons r Répéter les étapes 2 à 4 pour chaque période à modifier s Appuyer ...

Page 4: ...ent peut vous être expédié La présente garantie ne couvre pas les frais de retrait ou de réinstallation La présente garantie ne s appliquera pas s il est démontré que la défectuosité ou le mauvais fonctionnement est dû à un endommagement du produit alors que le consommateur l avait en sa possession La responsabilité de Honeywell se limite à réparer ou à remplacer le produit conformément aux modali...

Reviews: