![Honeywell THP9045A Installation Manual Download Page 10](http://html.mh-extra.com/html/honeywell/thp9045a/thp9045a_installation-manual_2158509010.webp)
10
5b Wire two-stage heat, single-stage cooling
1. Do
not
disconnect the W2 wire from your heating/cooling system.
2. Disconnect the R wire from your heating/cooling system’s terminal block.
3. Connect the R wire to the Rc terminal on the
THERMOSTAT
end of the wire saver.
4. Disconnect the W wire from the heating/cooling system; connect it to W on the
THERMOSTAT
end of the wire saver.
5. Disconnect the G wire; connect it to K on the
THERMOSTAT
end of the wire saver.
6. Disconnect the Y wire; connect it to C on the
THERMOSTAT
end of the wire saver.
7. Connect stripped ends of the included wire bundle to the terminals labeled
EQUIPMENT
on the wire saver in this color order:
a. Connect red to Rc
b. Connect yellow to Y
c. Connect green to G
d. Connect blue to C
e. Connect white to W
8. Connect the other set of stripped ends to the terminals on your heating/cooling system
following the same color order.