background image

Operating Manual

2

69-2667ES—01

About your new thermostat

Congratulations! You’ve just purchased the world’s most advanced, easy-to-use thermo-
stat. It has been designed to give you many years of reliable service and touchscreen 
climate control.

Features

•  7-day program schedules maximize comfort and economy.
•  Armchair programming: Just pull thermostat from the wall to set schedules.
•  Energy-saving settings for maximum cost savings.
•  One-touch temp control overrides program schedule at any time.
•  Precise comfort control keeps temperature within 1°F of the level you set.
•  Change/check reminders let you know when to service or replace filters, batteries 

and other critical components.

•  Large touchscreen display with backlight is easy to read—even in the dark.
•  Select models accommodate optional outdoor or indoor remote sensors.

Summary of Contents for TH7000 Series

Page 1: ...Operating Manual TH7000 Series Touchscreen Programmable Thermostat 69 2667ES 01 ...

Page 2: ...ed BE CAREFUL Never use sharp instruments such as a pencil or pen to press touchscreen keys To prevent damage to the thermostat always press keys with your fingertip This thermostat contains a Lithium battery which may contain Perchlorate material Perchlorate Material special handling may apply See www dtsc ca gov hazardouswaste perchlorate This manual covers the following models TH7220U For up to...

Page 3: ...eatures 14 Furnace filter reminder 15 Special features 16 Screen lock 17 Appendices Battery replacement 18 Advanced functions 19 In case of difficulty 25 Optional remote sensors 27 Limited warranty 28 This thermostat is ready to go Your new thermostat is pre programmed and ready to go See page 3 to check settings CAUTION EQUIPMENT DAMAGE HAZARD To prevent possible compressor damage do not operate ...

Page 4: ...mchair programming Just pull thermostat from the wall to set schedules Energy saving settings for maximum cost savings One touch temp control overrides program schedule at any time Precise comfort control keeps temperature within 1 F of the level you set Change check reminders let you know when to service or replace filters batteries and other critical components Large touchscreen display with bac...

Page 5: ... fan setting Preset to Auto See page 7 3 Select system setting Preset to Heat See page 8 4 Program schedules Preset to energy saving levels while you re at work or asleep assumes you wake at 6 am leave at 8 am return at 6 pm and go to bed at 10 pm See pages 9 11 ONE TOUCH TEMP CONTROL You can override the program schedule at any time and manually adjust the temperature see pages 11 13 This thermos...

Page 6: ...em type see page 8 Arrow keys Press to adjust temperature see pages 11 14 or to make selections from screen menus Schedule Press to set program schedule see page 11 Clock More Press to set clock see page 6 or furnace filter reminder Quick reference to controls If the screen backlight is off the first button press will only activate the backlight and the button must be pressed again ...

Page 7: ... temperature Current day of week Temperature setting Fan setting see page 7 Other display messages Cool On Cooling system is activated Heat On Heating system is activated Aux Heat On Auxiliary heating system is activated Quick reference to status display System setting see page 8 Adaptive Intelligent Recovery in effect see page 16 Current time ...

Page 8: ... and hold s or t to advance the time more quickly Press DONE to save exit or press GO BACK to exit without changing the time Note The real time clock should never require adjustment since it automatically updates for daylight saving time and stores all date time information Note To change the current week day display see pages 19 20 Press CLOCK MORE Adjust time then press DONE Clock setting ...

Page 9: ...e System Heat Fan Auto M31504 System Fan Schedule Clock More Press SYSTEM FAN to select fan operation On Fan is always on Auto Fan runs only when the heating or cooling system is on Fan setting Press SYSTEM FAN Press FAN to select mode then press DONE ...

Page 10: ...g on the indoor temperature Off All systems are off Em Heat only for heat pumps with auxiliary heat Thermostat controls Emergency and Auxiliary Heat Compressor is locked out System setting M27529 System Fan Done System Heat Fan Auto M31504 System Fan Schedule Clock More Press SYSTEM FAN Press SYSTEM to select mode then press DONE Note The Auto and Em Heat system settings may not appear depending o...

Page 11: ... and the temperature you want during the morning until you leave for the day Set to the time you leave home and the temperature you want while you are away usually an energy saving level Set to the time you return home and the temperature you want during the evening until bedtime Set to the time you go to bed and the temperature you want overnight usually an energy saving level WAKE 6 00 am 70 LEA...

Page 12: ...ram settings See next page to adjust times and temperatures of each time period Wake 6 00 am Leave 8 00 am Return 6 00 pm Sleep 10 00 pm Cool Mon Fri Heat Mon Fri Heat Sat Sun Cool Sat Sun 70 78 70 78 62 85 62 85 70 78 70 78 62 82 62 82 Energy saving settings for maximum cost savings ...

Page 13: ...settings 3 Press NEXT STEP twice then press s or t to set Wake time for selected day s 4 Press NEXT STEP then s or t to set Heat temperature for this time period 5 Press NEXT STEP then s or t to set Cool temperature for this time period 6 Repeat steps 3 5 to program other time periods LEAVE RETURN SLEEP then press DONE 7 Repeat steps 1 6 to program Saturday Sunday Press s or t until the desired da...

Page 14: ... ature This will temporarily override the tempera ture setting for the current time period The new temperature will be maintained until the next time period When the timer expires the program schedule will resume and set the temperature to the level you ve programmed for the current time period To cancel the temporary setting at any time press USE SCHEDULE Adjust temperature Press USE SCHEDULE to ...

Page 15: ...permanent Adjust temperature Press s or t to adjust temperature then press HOLD This will turn off the program schedule Whatever temperature you set will be maintained 24 hours a day until you manually change it or press USE SCHEDULE to cancel Hold and resume the program schedule Press HOLD to turn off program schedule and maintain set temperature ...

Page 16: ...degree difference between the heat and cool settings See example below The triangle indicates the cool temperature is increasing to maintain 3 degrees between heat and cool settings Auto Changeover Tue System Hold Cancel M27534 System Auto Heat Fan Auto Temporary Set To Heat Cool PM 69 74 1 09 º CAUTION To avoid possible compressor damage do not use Auto Changeover if the outside temperature drops...

Page 17: ...7536 60 Days If activated during installation the furnace filter reminder alerts you when it is time to replace your filter Press RESET after changing the filter to restart the timer To reset the reminder interval before it expires 1 Press MORE then NEXT 2 Press RESET 3 Press DONE to save and exit Press MORE to reset reminder interval Press RESET after changing filter ...

Page 18: ...ake to reach programmed temperature settings so the temperature is reached at the time you set For example Set the Wake time to 6 am and the temperature to 70 The heat will come on before 6 am so the temperature is 70 by the time you wake at 6 The message Recovery is displayed when the system is acti vated before a scheduled time period Compressor Protection This feature forces the compressor to w...

Page 19: ... can be partially or fully locked When partially locked the screen displays LOCKED for several seconds if a locked key is pressed To unlock the screen press any unlocked key while LOCKED appears on the screen When the screen is fully locked no keys function To lock or unlock the screen see advanced func tion 0670 on page 24 See advanced function 0670 page 24 for screen lock options ...

Page 20: ...tat was wired to run on AC power when installed Install fresh batteries immediately when the LO BATT warning begins flashing The warning flashes about 30 days before batteries are depleted Even if the warning does not appear you should replace batteries once a year or before leaving home for more than a month For assistance with this product please visit http yourhome honeywell com or call Honeywe...

Page 21: ...System Fan Schedule Clock More MCR31509 2 Press and hold center FAN key until the display changes 1 Press SYSTEM FAN Press s t to change setting Press NEXT to advance to next function 3 Change settings as required see pages 21 24 4 Press DONE to exit save changes Note Some functions in the following pages may not appear due to previous selections made ...

Page 22: ...o digits of the year Options 20 Year 20xx 21 Year 21xx Year setting second two digits Function 0130 Press s t to change the last two digits of the year Options 01 99 i e 2001 2099 Month setting Function 0140 Press s t to change the current month Options 1 12 i e January December Date setting Function 0150 Press s t to change the current date Options 1 31 ...

Page 23: ...t is non programmable 4 Program schedule is on 7 day programmable Restore energy saving schedule Function 0165 Press s t to turn the energy saving schedule on or off Options 0 Continue using programmed schedule 1 Restore thermostat program to energy saving settings Temperature format F C Function 0320 Press s t to set the temperature display format Options 0 Fahrenheit 1 Celsius ...

Page 24: ...aylight savings time 2007 and beyond for areas that use the new 2007 DST calendar Furnace filter change reminder Function 0500 This feature displays an alert to remind you to change the furnace filter Press s t to set the desired reminder interval Options 0 Off no reminder to change furnace filter 1 Reminder after 10 day run time about 1 month 2 Reminder after 30 day run time about 3 months 3 Remi...

Page 25: ...ths 2 Reminder after 6 months 3 Reminder after 1 year UV lamp change reminder Function 0520 This feature displays an alert to remind you to change the ultraviolet lamp Press s t to set the desired interval Options 0 Off no reminder to change UV lamp 1 Reminder after 1 year Adaptive Intelligent Recovery Function 0530 Press s t to turn on or off Adaptive Intelligent Recovery Early Start Options 0 Of...

Page 26: ...rogram periods Wake Leave Return Sleep Clock format Function 0640 Press s t to set the clock display format Options 12 12 hour clock i e 3 30 pm 24 24 hour clock i e 15 30 Screen lock Function 0670 Press s t to choose a screen lock setting see page 17 Options 0 Screen is unlocked fully functional 1 All functions locked except temperature controls and CANCEL key 2 Screen is fully locked ...

Page 27: ...alkaline batteries are correctly installed see page 18 No response to key presses or temperature will not change Check to make sure the thermostat is not locked see page 17 Make sure heating and cooling temperatures are set to acceptable ranges Heat 40 to 90 F 4 5 to 32 C Cool 50 to 99 F 10 to 37 C Backlight is dim If thermostat is battery powered make sure fresh AA alkaline batteries are correctl...

Page 28: ...ure Press SYSTEM to set system to Cool Make sure the temperature is set lower than the Inside temperature Check circuit breaker and reset if necessary Make sure power switch at heating cooling system is on Make sure furnace door is closed securely If Wait is displayed the compressor protection timer is on Wait 5 minutes for the system to restart safely without damaging the compressor see page 14 ...

Page 29: ...em Fan Schedule Clock More M31502 System Cool Fan Auto Set To Cool On AM 75 75 6 01 Optional remote sensors select models To see outdoor temperature Press Clock More Press Next Outside temperature MCR31505 Go Back Done Next MON AM 6 01 Next Done MCR31512 Outside 43 ...

Page 30: ...display shows the indoor temperature at the location of the sensor The internal sensor in the thermostat is disabled If more than one indoor sensor is installed the display shows an average of temperature readings from all sensors Mon System Fan Schedule Clock More MCR31513 System Cool Fan Auto Set To AM 75 75 6 01 ...

Page 31: ...as caused by damage which occurred while the product was in the possession of a consumer Honeywell s sole responsibility shall be to repair or replace the product within the terms stated above HONEYWELL SHALL NOT BE LIABLE FOR ANY LOSS OR DAMAGE OF ANY KIND INCLUDING ANY INCIDENTAL OR CONSEQUENTIAL DAMAGES RESULTING DIRECTLY OR INDIRECTLY FROM ANY BREACH OF ANY WARRANTY EXPRESS OR IMPLIED OR ANY O...

Page 32: ...c 1985 Douglas Drive North Golden Valley MN 55422 http yourhome honeywell com U S Registered Trademark 2012 Honeywell International Inc US Patents pending 69 2667ES 01 M S 03 12 Printed in U S A Automation and Control Solutions ...

Page 33: ...Manual de funcionamiento Serie TH7000 Termostato con pantalla táctil programable ...

Page 34: ... filosos como un lápiz o un lapicero para presionar las teclas de la pantalla táctil Siempre presione las teclas con la punta de los dedos para evitar dañar el termostato Este termostato tiene baterías de litio que pueden contener material con perclorato Material con perclorato es posible que deba aplicarse un tratamiento especial Visite www dtsc ca gov hazardouswaste perchlorate Este manual inclu...

Page 35: ...io de cambio del filtro del sistema de calefacción 15 Características especiales 16 Bloqueo de pantalla 17 Apéndices Reemplazo de las baterías 18 Funciones avanzadas 19 En caso de inconvenientes 25 Sensores remotos opcionales 27 Garantía limitada 28 Este termostato está listo para funcionar Su nuevo termostato está preprogramado y listo para funcionar Consulte la página 3 para revisar las configur...

Page 36: ...ente retire el termostato de la pared para configurar la programación Configuraciones de ahorro de energía para máximo ahorro de costos El control de temperatura al tacto anula el cronograma del programa en cualquier momento El control preciso del confort conserva la temperatura en el rango de 1 F 0 5 C del nivel que haya configurado Los recordatorios de cambio revisión le permiten saber cuándo pr...

Page 37: ...gina 7 3 Selección de la configuración del sistema predeterminada en Heat Calefacción Consulte la página 8 4 Cronogramas del programa predeterminados en niveles de ahorro de energía mientras está en el trabajo o duerme el termostato asume que usted se levanta a las 6 a m se va a las 8 a m regresa a las 6 p m y se va a dormir a las 10 p m Consulte las páginas 9 11 CONTROL DE TEMPERATURA AL TACTO Us...

Page 38: ...s con flechas Presione para ajustar la temperatura consulte las páginas 11 14 o para seleccionar de los menús de pantalla Cronograma Presione para configurar el cronograma del programa consulte la página 11 Reloj y más Presione para configurar el reloj consulte la página 6 o el recordatorio del cambio del filtro del equipo de calefacción Referencia rápida de los controles Si la luz de fondo de la ...

Page 39: ... de la temperatura Configuración del ventilador consulte la página 7 Otros mensajes de la pantalla Cool On el sistema de refrigeración está activado Heat On el sistema de calefacción está activado Aux Heat On el sistema de calefacción auxiliar está activado Referencia rápida de la pantalla de estado Configuración del sistema consulte la página 8 Adaptive Intelligent Recovery en efecto consulte la ...

Page 40: ...ra avanzar la hora más rápidamente Presione DONE para guardar y salir o presione GO BACK retroceder para salir sin cambiar la hora Nota El reloj en tiempo real nunca debería tener que ajustarse ya que se actualiza automáticamente al horario de verano y guarda la información de la fecha hora Nota Para cambiar la pantalla del día actual de la semana consulte las páginas 19 20 Presione CLOCK MORE rel...

Page 41: ...or para seleccionar el funcionamiento del ventilador On encendido el ventilador está siempre encendido Auto automático el ventilador funciona únicamente cuando el sistema de calefacción o de refrigeración está encendido Configuración del ventilador Presione SYSTEM FAN sistema y ventilador Presione FAN ventilador para seleccionar la modalidad y luego presione DONE terminado ...

Page 42: ...a interior Off apagado Todos los sistemas están apagados Em Heat calefacción de emergencia solamente para bombas de calor con calefacción auxiliar el termostato controla la calefacción auxiliar y de emergencia El compresor se bloquea Configuración del sistema M27529 System Fan Done System Heat Fan Auto M31504 System Fan Schedule Clock More Presione SYSTEM FAN sistema y ventilador Presione SYSTEM s...

Page 43: ...erta y la temperatura que desea durante la mañana hasta que se marche de su casa Programe la hora en que se marcha y la temperatura que desea mien tras no está en su casa por lo general un nivel de ahorro de energía Programe la hora en que regresa a su casa y la temperatura que desea durante la tarde hasta que se va a dormir Programe la hora en que usted se va a dormir y la temperatura que desea d...

Page 44: ...grama de ahorro de energía Consulte la página siguiente para ajustar las horas y las temperaturas de cada período Wake 6 00 am Leave 8 00 am Return 6 00 pm Sleep 10 00 pm Cool lun vie Heat lun vie Heat sáb dom Cool sáb dom 70 78 70 78 62 85 62 85 70 78 70 78 62 82 62 82 Configuraciones de ahorro de energía para máximo ahorro de costos ...

Page 45: ...resione s o t para configurar la hora de despertar el los día s seleccionado s 4 Presione NEXT STEP luego s o t para configurar la temperatura de calefacción para ese período 5 Presione NEXT STEP luego s o t para configurar la temperatura de refrigeración para ese período 6 Repita los pasos 3 al 5 para programar otros períodos de tiempo LEAVE RETURN SLEEP salir regresar dormir y luego presione DON...

Page 46: ...Esto anulará temporalmente la configuración de la temperatura para el período actual La temperatura nueva se mantendrá hasta el siguiente período Cuando el temporizador finalice el cronograma del programa se reanudará y fijará la tempera tura al nivel que ha programado para el período actual Para cancelar esta configuración temporal en cualquier momento presione USE SCHEDULE Ajuste de la temperatu...

Page 47: ...e s o t para ajustar la temperatura luego presione HOLD Esto desactivará el crono grama del programa Cualquiera que sea la temperatura que config ure esta se mantendrá las 24 horas del día hasta que la cambie manualmente o presione USE SCHEDULE usar cronograma para cancelar Hold mantener y retomar el cronograma del programa Presione HOLD mantener para desactivar el cronograma del programa y manten...

Page 48: ...erencia de 3 grados entre las configuraciones de calefacción o refrigeración Consulte el ejemplo a continuación El triángulo indica que la temperatura fría está aumentando para mantener 3 grados entre las configuraciones para calor y frío Conversión automática Tue System Hold Cancel M27534 System Auto Heat Fan Auto Temporary Set To Heat Cool PM 69 74 1 09 º PRECAUCIÓN Para evitar posibles daños al...

Page 49: ... recordato rio del filtro del equipo de calefacción le alerta cuando es el momento de cambiar su filtro Presione RESET después de cambiar el filtro para reiniar el temporizador Para reiniciar el intervalo de los recordatorios antes de de que termine 1 Presione MORE y luego NEXT siguiente 2 Presione RESET 3 Presione DONE terminado para guardar y salir Presione MORE más para reiniciar el intervalo d...

Page 50: ...canzar las con figuraciones de temperatura programadas de manera que se alcance esa temperatura a la hora que usted configuró Por ejemplo Configure la hora de despertarse a las 6 a m y la temperatura en 70 F 21 C La calefacción se activará antes de las 6 a m para que la temperatura sea 70 F 21 C a la hora que usted se despierte a las 6 El men saje Recovery recuperación se mostrará cuando el sistem...

Page 51: ...á parcialmente bloqueada la pan talla muestra LOCKED bloqueada durante varios segundos si se presiona una tecla bloqueada Para desbloquear la pantalla presione cualquier tecla desbloqueada mientras LOCKED aparezca en la pantalla Cuando la pantalla esté totalmente bloqueada ninguna tecla funciona Para bloquear o desblo quear la pantalla refiérase a la función avanzada 0670 en la página 24 Refiérase...

Page 52: ...ar con corriente CA cuando fue instalado Instale las baterías nuevas inmediatamente cuando el aviso LO BATT baterías bajas comience a titilar El aviso destellará durante 30 días aproximadamente antes de que se agoten las baterías Incluso si el aviso no aparece siempre debe reempla zar las baterías una vez al año o antes de abandonar el hogar por más de un mes Para obtener ayuda sobre este producto...

Page 53: ...N ventilador hasta que la pantalla cambie 1 Presione SYSTEM FAN sistema y ventilador Presione s t para cambiar la configuración Presione NEXT siguiente para avanzar hasta la siguiente función 3 Cambie las configuraciones según se requiera consulte las páginas 21 24 4 Presione DONE terminado para salir y guardar los cambios Nota Algunas funciones de las páginas siguientes puede que no aparezcan deb...

Page 54: ... del año Opciones 20 Año 20xx 21 Año 21xx Configuración del año segundos dos dígitos Función 0130 Presione s t para cambiar los dos últimos dígitos del año Opciones 01 99 por ej 2001 2099 Configuración del mes Función 0140 Presione s t para cambiar el mes actual Opciones 1 12 por ej enero diciembre Configuración de la fecha Función 0150 Presione s t para cambiar la fecha actual Opciones 1 31 ...

Page 55: ...cronograma del programa está activado programable para 7 días Restituya la programación de ahorro de energía Función 0165 Presione s t para activar o desactivar el cronograma de ahorro de energía Opciones 0 Continúe utilizando el cronograma programado 1 Restablezca la programación del termostato a la configuración de ahorro de energía Formato de la temperatura F C Función 0320 Presione s t para co...

Page 56: ... del equipo de calefacción Función 0500 Esta función muestra una alerta para recordarle que cambie el filtro del equipo de calefacción Presione s t para configurar el intervalo de recordatorio deseado Opciones 0 Desactivado ningún recordatorio para cambiar el filtro del equipo de calefacción 1 Recordatorio después de 10 días de tiempo de funcionamiento aproximadamente 1 mes 2 Recordatorio después ...

Page 57: ...ordatorio después de 6 meses 3 Recordatorio después de 1 año Recordatorio de cambio de la lámpara UV Función 0520 Esta función muestra una alerta para recordarle que cambie la lámpara ultravioleta Presione s t para configurar el intervalo deseado Opciones 0 Desactivado ningún recordatorio para cambiar la lámpara UV 1 Recordatorio después de 1 año Adaptive Intelligent Recovery Función 0530 Presione...

Page 58: ...rn regresar Sleep dormir Formato del reloj Función 0640 Presione s t para configurar el formato de la visualización del reloj Opciones 12 Reloj de 12 horas por ej 3 30 p m 24 Reloj de 24 horas por ej 15 30 Bloqueo de pantalla Función 0670 Presione s t para elegir una configuración de bloqueo de pantalla consulte la página 17 Opciones 0 La pantalla está desbloqueada totalmente funcional 1 Todas las...

Page 59: ...inas AA nuevas estén instaladas correctamente consulte la página 18 Las teclas no funcionan al presionarlas o la temperatura no cambia Revise para comprobar que el termostato no esté bloqueado refiérase a la página 17 Asegúrese de que las temperaturas de calor y frío estén configuradas en rangos aceptables Heat calefacción 40 F a 90 F 4 5 C a 32 C Cool refrigeración 50 F a 99 F 10 C a 37 C La luz ...

Page 60: ...ol refrigeración Asegúrese de que la temperatura sea más baja que la temperatura interior Revise el interruptor de circuito y si es necesario reinícielo Asegúrese de que el interruptor de energía del sistema de calefacción y refrigeración esté encendido Asegúrese de que la puerta del sistema de calefacción esté bien cerrada Si en la pantalla aparece Wait esperar el temporizador de protección del c...

Page 61: ... More M31502 System Cool Fan Auto Set To Cool On AM 75 75 6 01 Sensores remotos opcionales ciertos modelos Para ver la temperatura exterior Presione Clock More reloj y más Presione Next siguiente Temperatura exterior MCR31505 Go Back Done Next MON AM 6 01 Next Done MCR31512 Outside 43 ...

Page 62: ...riores la pantalla muestra la temperatura interior en la ubicación del sensor El sensor interno del termostato está deshabilitado Si se ha instalado más de un sensor en interiores la pantalla muestra un promedio de las lecturas de temperatura de todos los sensores Mon System Fan Schedule Clock More MCR31513 System Cool Fan Auto Set To AM 75 75 6 01 ...

Page 63: ...por daños que se produjeron mientras el producto estuvo en posesión de un consumidor La única responsabilidad de Honeywell será la de reparar o reemplazar el producto dentro de los términos mencionados anterior mente HONEYWELL NO SERÁ RESPONSABLE POR LA PÉRDIDA NI DAÑO DE NINGÚN TIPO QUE INCLUYE CUALQUIER DAÑO INCIDENTAL O CONSECUENTE QUE RESULTE DIRECTA O INDIRECTAMENTE DE CUALQUIER INCUMPLIMIENT...

Page 64: ...Drive North Golden Valley MN 55422 http yourhome honeywell com Marca comercial registrada en los EE UU 2012 Honeywell International Inc Patentes de EE UU en trámite 69 2667ES 01 M S 03 12 Impreso en EE UU Soluciones de control y automatización ...

Reviews: