The unit is in a searching mode.

Temperature and readings is 

securely registered.

No signals detected.

- - -

GETTING STARTED

WEATHER DISPLAY

After batteries are installed; remote sensor will transmit 

temperature and humidity data at 45 second intervals. The 

main unit may take up to two minutes to receive the initial 

readings. Upon successful reception, remote temperature 

will appear under the weather forecast section of the main 

unit’s display (the default remote channel is channel one). 

The main unit will automatically update readings at 45-

second intervals.

After communication between the main unit and remote 

sensor has been established, secure the remote sensor in 

the desired location.

If no signal is received from the remote sensor within two 

minutes, dashes [- - -] will be displayed. Press and hold the 

DOWN (     ) button on the main unit for two seconds to 

initiate another signal search.

 

PLACEMENT OF THE UNITS

The main unit can be placed on any flat surface 

indoors

The remote sensor can be placed 

indoors 

or 

outdoors

, on 

a flat surface or mounted on the wall.

NOTE: When the temperature falls below freezing, the 

batteries in the outdoor remote sensor may have reduced 

voltage supply and a shorter effective range. We 

recommend using lithium batteries at temperatures of 

32

°

F (0

°

C) and below.

BATTERY INSTALLATION

REMOTE SENSOR

NOTE: Install the batteries; select the channel and 

temperature in 

°

C or 

°

F before mounting the remote 

sensor.

• Remove the screws from the battery compartment with a 

small Phillips screwdriver.

• Set the channel. The switch is located in the battery 

compartment. Channel 1 is typically selected if only one 

remote sensor is being used.

• Install 2 “AAA” size alkaline batteries (not included) 

matching the polarities shown in the battery compartment.

• Replace the battery compartment door and secure the 

screws.

• Secure the remote sensor in the desired location.

 

MAIN UNIT

• Remove the battery compartment door.

• Install 2 batteries (UM-3 or “AA” size 1.5V) matching 

the polarity as shown in the battery compartment.

• Replace the battery compartment door.

LOW BATTERY WARNING

A low-battery indicator [     ] will appear next to the indoor 

or remote data reading line of the main unit warning that 

the corresponding batteries need replacement.

REMOTE AND INDOOR TEMPERATURE & HUMIDITY

The remote temperature and humidity information line is 

located right below the weather forecast line of the main 

unit’s display.

The wave icon is located above the remote channel number 

indicates the reception status from the corresponding remote 

sensor.

There are three following types of the reception status may 

be displayed:

The indoor temperature and humidity with the icon       is 

located below the remote temperature and humidity 

information line.

NOTE

: If the indoor or remote temperature or humidity 

goes above or below operating range stated in 

specifications, the main unit’s display ( weather) will show 

dashes “- - -” on the corresponding line.

AUTO-SCANNING

Press and hold the 

CHANNEL 

button for 2 seconds – the 

icon “      ” will appear on the main unit display to the left 

of the 

COMFORT LEVEL

 indicator.

All three remote channels data will be displayed one-by-

one automatically with 11 seconds delay in the following 

sequence: Channel 1, Channel 2 and Channel 3.

To exit from scanning mode, press and hold the 

CHANNEL

 button for 2 seconds, and the icon “      ” will 

disappear, returning the main unit display to the default 

display mode.

PROGRAMMABLE TEMPERATURE ALARM

This product allows manual programming of a 

HIGH 

and 

LOW 

temperature alarms for all three remote channels at 

the same time. Once the actual remote temperature will 

reach the pre-set high or low limits, the alarm will sound. 

The alarm can be set for temperature readings between -58 

°

and 158

°

F.

To program the temperature alarm for all three remote 

channels,

• Press the 

TEMP AL

 button once to enter into the 

High 

Temperature Alarm

 programming mode – the 

abbreviation “

OF

” with the high temperature limit 

symbol (     ) will be displayed on the remote 

temperature line

• Press and hold 

TEMP AL

 button until the abbreviation 

OF

” will flash

• Use 

UP

(     ) or 

DOWN

(     ) arrow buttons to adjust the 

higher temperature limit

• Press the 

TEMP AL 

button to confirm the selected value

• Press the 

TEMP AL

 button once to enter into the 

Low 

Temperature Alarm

 programming mode – the 

abbreviation “

OF

” with the low temperature limit 

symbol (     ) will be displayed on the remote 

temperature line

• Press and hold 

TEMP AL

 button until the abbreviation 

OF

” will flash

• Use 

UP

(     ) or 

DOWN

(     ) arrow buttons to adjust the 

lower temperature limit

• Press the 

TEMP AL

 button to confirm the selected value

Summary of Contents for TE532ELW

Page 1: ... displayed in English Spanish French German and Italian Weather Forecast in Sunny Partly Cloudy Cloudy Rainy and Snowy icons Long Range Wireless Reception of the Temperature and Humidity from the Remote Sensor to the Main Unit from up to 328 feet 100 meters away Multi Channel Capability to Monitor Temperature and Humidity in up to 3 Remote Locations Three Remote Channels Auto Scan feature Minimum ...

Page 2: ... transmission to the main unit via 433 MHz frequency Case can be wall mounted using built in hanger Selection of the temperature display in Celsius or Fahrenheit Three channel selection LCD displays temperature humidity and channel A LED INDICATOR Flashes once when the remote sensor transmits a reading to the main unit Flashes twice when battery power is low B BATTERY COMPARTMENT Holds two AAA siz...

Page 3: ... unit warning that the corresponding batteries need replacement REMOTEANDINDOORTEMPERATURE HUMIDITY The remote temperature and humidity information line is located right below the weather forecast line of the main unit s display The wave icon is located above the remote channel number indicates the reception status from the corresponding remote sensor There are three following types of the recepti...

Page 4: ...the atomic time signal The search usually takes between 5 8 minutes NOTE Do not press any buttons on the main unit during auto search as it may interrupt product s operation and you will need to start set up procedure again Once the atomic time signal is received the date and time will be set automatically and the icon will appear NOTE It is necessary to set your Time Zone having in mind that the ...

Page 5: ...ogrammed Press ALARM button once to enter into the Ice Warning Alarm setting mode The abbreviation OFF with a PRE AL next to it will be displayed Press and hold ALARM button for two seconds The number 30 will flash meaning that if selected the alarm will sound 30 minutes earlier than the Weekday or Single alarm Select the desired Ice Warning Alarm interval in 15 minutes increments between 15 and 9...

Page 6: ...86 D inches FCC STATEMENT This device complies with Part 15 of the FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 This device must accept any interference received including interference that may cause undesired operation Warning Changes or modification to this unit not expressly approved by the party responsible for compliance...

Reviews: