Doc No: MM5008E – Revision 6 – ENG
Data Processing Racks
TA3840 Maintenance Manual
13
Error codes
Beginning
code
End
code
Default
001
101
Radar transmitter communication
002
102
Radar transmitter location (not used)
003
103
Autotest fault when the radar transmitter is powered up (not used)
004
104
MW board failure (not used)
005
105
Too low signal from radar transmitter (not used)
006
106
Radar transmitter wrong distance measurement
007
107
Radar transmitter distance invalid measurement
008
108
Radar transmitter high temperature invalid measurement
009
109
Radar transmitter medium temperature invalid measurement
010
110
Radar transmitter low temperature invalid measurement
011
111
Radar connected analog transmitter 1 invalid measurement
012
112
Radar connected analog transmitter 2 invalid measurement
013
113
Radar connected analog transmitter 3 invalid measurement
014
114
4-20 mA analog transmitter invalid measurement
015
115
Monitoring 1 communication fault
016
116
Monitoring 2 communication fault
Software updating
In case of updating, Honeywell Marine can provide a set of 2 EPROM'S per soft, one "EVEN" and
one "ODD".
The EPROM'S have to be inserted on relevant electronic boards at the same location than the old
one's, taking care not to damage the pins of each EPROM.
●
The TA3840C soft is called SOFT 1024.
●
The TA3840R soft is called SOFT 1025.
●
The TA3840S soft (CPU board optional) are called:
-
SOFT 1004 for the CPU board standard (ref. M11555),
-
SOFT 1007 for the CPU board protocol P-Net (ref. M12922).