INSTALLER SETUP

NOTE: For most applications, the thermostat factory-

settings do not need to be changed. Review the 
factory default settings in Table 3 and, if no 
changes are necessary, go to the Installer Self-
Test section.

The Installer Setup is used to customize the thermostat 
to specific systems. Some of the options include 
temperature display and system changeover. Installer 
Setup numbers are listed in Table 3. The table includes 
all the configuration options and the factory-settings for 
the T8665.

A combination of key presses are required to use the 
Installer Setup feature:

— To enter the Installer Setup, press and hold the 

Information 

key with the increase 

V

 and decrease 

W

 

keys until the first number is displayed. All display 
segments appear for approximately three seconds 
before the number is displayed. See Fig. 7 and 8.

— To advance to the next Installer Setup, press the Time 

V

 

key.

— To change a setting, use the increase 

V

 or decrease

 

W

 

key.

— To scroll the Installer Setup numbers backward, press 

the Time 

W

 key.

— To exit the Installer Setup, press Run Program.

Fig. 7. DIsplay of all LCD segments.

Fig. 8. Display of Installer Setup number

 and settings.

CAUTION

Equipment Damage Hazard.
Electric heat and heat pump systems must 
run with fan.

Configure to 1 in Installer Setup number 2 to 
prevent equipment damage.

IMPORTANT

Only configured numbers are shown on the 
device.For example: If thermostat does not 
have a system key, Installer Setup Number 12 
will not display. Review Table 3 factory settings 
and mark any desired changes in the Actual 
Settings column. When Installer Setup is com-
plete, review the settings to confirm they Mat-
thew system. 

M14559

Aux Ht

Set Day/Time

Set Program

Mon
Wake Leave Return

Sleep

Outdoor

Room

Filter

Wait

System

Fan

Em Heat

On

Auto

Off

Cool

Auto

AM

PM

Hold for

Heat

Cool

Repl Batt

Recovery

DST

Tue Wed Thu Fri Sat Sun

Days

Temporary Setting

Em Ht

M14618

INSTALLER SETUP
NUMBER DISPLAY
(COLUMN 2 OF TABLE 3)

FACTORY SETTING OR OTHER 
CHOICE DISPLAY (COLUMN 3
OR 5 OF TABLE 3)

Summary of Contents for T8665A Chronotherm IV

Page 1: ...ur application 3 Installer must be a trained experienced service technician 4 After completing installation use these instructions to check out the product operation Location Install the thermostat about 5 ft 1 5m above the floor in an area with good air circulation at average temperature See Fig 1 Do not install the thermostat where it can be affected by drafts or dead spots behind doors and in c...

Page 2: ...nd wall plate See Fig 3 2 Press lower edge of case to close and latch NOTE To remove the thermostat from the wall first pull out at the bottom of the thermostat remove top last Fig 3 Mounting thermostat on wallplate 5 FEET 1 5 METERS YES NO NO NO M10106 WALL MOUNTING HOLES M20592 MOUNTING SCREWS WALL ANCHORS 2 M14628 PRESS LOWER EDGE OF CASE TO LATCH ENGAGE TABS AT TOP OF THERMOSTAT AND WALLPLATE ...

Page 3: ...p one zone at a time to ensure a unique address is used for each zone 1 Place the Zone 1 DIP switch on the W8665E Receiver to the On position NOTE Observe that the Zone 1 LED on the W8665 flashes 2 Press the thermostat Fan key to the On position The Receiver accepts the message stores the identity of that zone and stops flashing the Zone 1 LED The thermostat is now set up to send signals to Zone 1...

Page 4: ...he system fan as follows On Fan operates continuously Auto Fan operates with equipment Fig 6 Thermostat System and Fan key locations NOTE Always press the keys with your fingertip or sim ilar blunt tool Sharp instruments like a pen or pencil point can damage the keyboard Programmed Temperature Settings Refer to Table 2 for the default program If the daytime energy savings period is not used press ...

Page 5: ...r Setup press the Time V key To change a setting use the increase V or decrease W key To scroll the Installer Setup numbers backward press the Time W key To exit the Installer Setup press Run Program Fig 7 DIsplay of all LCD segments Fig 8 Display of Installer Setup number and settings CAUTION Equipment Damage Hazard Electric heat and heat pump systems must run with fan Configure to 1 in Installer...

Page 6: ...system starts early so setpoint is reached by start of program period 1 Conventional recovery system starts recovery at programmed time Degree temperature display 14 0 Temperature is displayed in F 1 Temperature is displayed in C Not used 15 Clock format 16 0 12 hour clock format 1 24 hour clock format Not used 17 and 18 Extended fan operation in heatinga 19 0 No extended fan operation after the c...

Page 7: ...ture display adjustment 37 0 No difference in displayed temperature and actual room temperature 3 thru 3 1 Display adjusts to 1 F higher than actual room temperature 2 Display adjusts to 2 F higher than actual room temperature 3 Display adjusts to 3 F higher than actual room temperature 1 Display adjusts to 1 F lower than actual room temperature 2 Display adjusts to 2 F lower than actual room temp...

Page 8: ...umber of days remaining at any time by pressing the i key three or four times If more than one timer is active all active timers show sequentially when pressing the i key several times M14619 Time Set Program System Fan Run Program Hold Temp Set Current Day Time Set Current Day Time Wake Leave Return Sleep Day Heat Cool Settings Daylight Time Copy Set Day Time Mon PM M14620 Time Set Program System...

Page 9: ...r Time W and then the Run Program key to exit Table 4 Tests Available in Installer System Test Test Number System Test Description 10 19 Heating equipment can be turned on and off 30 39 Cooling equipment can be turned on and off 40 49 Fan equipment can be turned on and off 60 0 to 60 19 Keyboard keys test 70 79 Thermostat information including date code and software versions are displayed M14559 A...

Page 10: ... of the year example 027 February 1997 3 Press the increase key V again to display the soft ware identification code Example 02 software ID code 2 4 Press the increase key V again to display the software revision number example 001 revision number 1 5 Press the increase V key again to display the EEPROM identification code example 314 EEPROM ID 314 6 Press the Run Program key to exit the system te...

Page 11: ...signals Thermostat minimum off time is activated Wait up to five minutes for the system to respond System selection is not set to Heat Set system selection to Heat Heating setpoint is below room temperature Check heating setpoint Set heating setpoint to desired temperature Cooling does not come on Thermostat minimum off time is activated Wait up to five minutes for the system to respond Enter Inst...

Page 12: ...nable protection against such interference in a residential installation However there is no guarantee that interference will not occur in a particular installation If this equipment does cause interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures I...

Reviews: