T8611G CHRONOTHERM
®
IV DELUXE PROGRAMMABLE HEAT PUMP THERMOSTAT
68-0165—1
20
Table 12. Troubleshooting Information (continued).
CROSS REFERENCE
All SUPER TRADELINE® Chronotherm® IV thermostats are different from the existing Chronotherm® III devices as
summarized in Table 13.
Table 13. Difference Between Chronotherm® III Thermostats And Chronotherm® IV Thermostats.
Feature/Function
Chronotherm® III Family
Chronotherm ® IV Family
Programming
5-1-1 day programming
7-day programming
Changeover
Automatic or manual changeover models available
Automatic/manual changeover selectable
Installer Configuration
Field settings made via screws on the back of the
thermostat
Field settings made through the keyboard
System switching
Mechanical switch
Keyboard entry
Fan switching
Mechanical switch
Keyboard entry
Device color
Beige or Premier White® color
Taupe or Premier White® color
Symptom
Possible Cause
Action
Cooling will not come
on (Continued).
Thermostat minimum off time is
activated.
•
Wait up to five minutes for the system to respond.
•
Enter Installer Setup number 33. Reconfigure minimum off
time (if required).
System selection is not set to Cool.
Set system selection to Cool.
Cool setpoint is above room
temperature.
Check cooling setpoint. Set cooling setpoint to desired
temperature.
Heating or cooling
come on momentarily
and shut off
Heat or cool circuit is opening up
or becoming high impedance.
Add resistor in parallel with load or install interface relay.
System on indicator
(flame=heat,
snowflake=cool) is
displayed, but no
warm or cool air is
coming from the
registers.
Heating or cooling equipment is
not operating.
Verify operation of heating or cooling equipment in System Test.
Outdoor temperature
not displayed
a
Option not activated.
Enter Installer Setup number 24 and set to 1. Thermostat must
have OT terminals and a C7089B1000 installed.
Outdoor temperature
display is incorrect
a
Outdoor sensor is connected
incorrectly.
Refer to C7089B1000 installation instructions and check wiring
between the thermostat and sensor.
Wrong sensor.
Replace sensor with C7089B1000 sensor.
a Available on select models