INSTALLATION INSTRUCTIONS

®U.S. Registered Trademark
Copyright © 2001 Honeywell   •            •   All Rights Reserved

T8034C

Heating/Cooling Thermostats

APPLICATION

These T8034C Thermostats control 24 to 30 Vac single-
stage heating-cooling systems. An spdt mercury switch
makes R (RH) to W on temperature fall for heating, and R
(RC) to Y on temperature rise for cooling. Integral switches
control HEAT-OFF-COOL system operation and ON-
AUTO or AUTO-ON  fan operation. Heat anticipation is
adjustable, 0.18A to 1.0A. See Fig. 1. Includes dual
Celsius/Fahrenheit temperature scale.

MERCURY NOTICE

If this control is replacing a control that contains
mercury in a sealed tube, do 

not

 place your old

control in the trash. Dispose of properly.

Contact your local waste management authority for
instructions regarding recycling and the proper
disposal of an old control.

MOUNTING HOLE
(THERMOSTAT 
TO WALL OR 
OUTLET BOX)

BIMETAL ELEMENT
BEHIND HEAT
ANTICIPATOR 
SCALE

SYSTEM
SWITCH

MOUNTING 
HOLE

TEMPERATURE
SETTING LEVER

FAN 
SWITCH

M5601

ADJUSTABLE HEAT
ANTICIPATOR INDICATOR

.25

.3

.35

.5

.7

.9

.2

.18

L

O N G

Fig. 1. Internal view of the T8034C.

INSTALLATION

When Installing this Product…

1. Read these instructions carefully. Failure to follow

them could damage the product or cause a hazard-
ous condition.

2. Check the ratings given in the Instructions and on

the product to make sure the product is suitable for
your application.

3. Installer must be a trained, experienced service

technician.

4. After installation is complete, check out product

operation as provided in these Instructions.

CAUTION

Can cause electrical shock or equipment
damage.

Disconnect power supply before beginning
installation.

Location

Locate the thermostat about 5 ft (1.5m) above the floor on
an inside wall in an area with good air circulation at
average temperature.

Do not mount the thermostat where it can be affected by:

drafts or dead spots behind doors or in corners.

hot or cold air from ducts.

radiant heat from the sun, fireplaces or appliances.

unheated (uncooled) areas such as outside walls
behind the thermostats.

This thermostat is a precision instrument and was carefully
adjusted at the factory. 

Handle it carefully.

Mounting and Wiring

Disconnect power supply before beginning installation to
prevent electrical shock or equipment damage. All wiring
must comply with local codes and ordinances.

The T8034C can be mounted directly on a wall or horizon-
tal outlet box. Use Honeywell part no. 200581 Horizontal
Wallplate (beige) to cover mounting marks left by the old
thermostat, or use Honeywell part no. 193121A Mounting
Plate Assembly (beige) to mount on vertical outlet box or
to cover wall marks where larger plate is needed. Order
the horizontal wallplate or mounting plate assembly
separately.

69-1598

Summary of Contents for T8034C

Page 1: ...eck the ratings given in the Instructions and on the product to make sure the product is suitable for your application 3 Installer must be a trained experienced service technician 4 After installation is complete check out product operation as provided in these Instructions CAUTION Can cause electrical shock or equipment damage Disconnect power supply before beginning installation Location Locate ...

Page 2: ... and discard the foam plastic shipping insert that protects the switch and bimetal assembly during shipping 5 Set the adjustable heat anticipator indicator to match the current draw of the primary heating control see Heat Anticipator Setting 6 Push excess wire back through the hole and plug any opening with insulation to prevent drafts that may affect thermostat performance 7 Loosely fasten the th...

Page 3: ...N AUTO COOL OFF HEAT COOL OFF HEAT SYSTEM SWITCH C1 ANTICIPATOR H1 ANTICIPATOR M1034F W 2 1 Y G R Fig 5 Internal schematic and typical hookup for T8034C in gas or oil fired or central electric heat systems M2297 POWER SUPPLY PROVIDE DISCONNECT MEANS AND OVERLOAD PROTECTION AS REQUIRED DEFROST RELAY SYSTEM SWITCH HEAT OFF COOL FAN SWITCH AUTO ON H1 TEMP FALL C1 ANTICIPATOR FAN RELAY HEAT OFF COOL C...

Page 4: ...ONNECTED THERMOSTAT WITH NOT ENERGIZE FAN IN AUTO POSITION JUMPER W Y FOR SINGLE STAGE HEAT PUMP APPLICATIONS HEAT RELAY FAN RELAY FAN SWITCH ON AUTO COOL OFF HEAT COOL OFF HEAT SYSTEM SWITCH C1 ANTICIPATOR H1 ANTICIPATOR M2323C W Y B O 2 G 1 R CHANGEOVER RELAY HEAT CHANGEOVER RELAY COOL COMPRESSOR RELAY Fig 8 Internal schematic and typical hookup for T8034C in single transformer heating cooling s...

Page 5: ... C1 1 POWER SUPPLY PROVIDE DISCONNECT MEANS AND OVERLOAD PROTECTION AS REQUIRED HEAT RELAY FAN RELAY FAN SWITCH ON AUTO COOL OFF HEAT COOL OFF HEAT SYSTEM SWITCH C1 ANTICIPATOR H1 ANTICIPATOR M13313 B O W Y G R L1 HOT L2 1 CHANGEOVER RELAY HEAT CHANGEOVER RELAY COOL COMPRESSOR RELAY 5 4 If the current rating is not available 1 Turn off the power 2 Wire the thermostat but do not mount it on the wal...

Page 6: ... With the system switch set at OFF and the fan switch at ON the fan should run continuously Move the fan switch to AUTO In standard systems fan operation is controlled by the plenum fan control in heating and by the thermostat in cooling In heat pump or electric heat systems fan operation is controlled by the thermostat in heating and cooling Recalibration These thermostats are calibrated at the f...

Reviews: