Page 1: ...t 50 m Twisted pair wire is recommended for wire runs longer than 100 ft 30 5 m CAUTION EMI Noise Introduction Risk of erratic system operation Keep wiring at least one ft 305 mm away from large inductive loads such as motors line starters lighting ballasts and large power distribution panels During installations try to avoid areas of high EMI noise Run wall module wiring separately from 50 Vac or...

Page 2: ...ers listed in Table 2 and if a SW version listed in Table 2 or higher is installed If the DWM is powered via terminal 5 the Excel 10 controller must be configured for LCD_DISPLAY LED output continuously ON NOTE The 24 Vac power supply is needed only with the T7560B DWM for the humidity sensor Alternatively a DC voltage source with 5 12 V can be connected to terminal 5 see IMPORTANT note above Alte...

Page 3: ...ring of DWM NOTE If connected to W7753 UV Controller both terminals 4 and 6 must be connected W7761 Remote I O Controller supports only terminals 2 temperature 7 humidity and 1 common as well as terminal 8 as voltage supply Wiring with terminal 8 is not necessary if An FCU or CHC controller with software is connected see table 2 An Excel 500 with 6V 8V 10V signaling from the controller is used The...

Page 4: ...ameter value 6 Confirm selection by pressing UNIT ENABLE 7 Repeat steps 4 to 6 to configure next parameter or press BYPASS to leave the configuration mode NOTE After approx 10 seconds without further action the DWM automatically falls back to normal mode P1 Setpoint Type Setting Scale Type Setting Fahrenheit relative Fahrenheit absolute Centigrade relative Centigrade absolute P2 Room Temperature S...

Page 5: ...cupied 01 enable FAN Key enable Setpoint Key 02 enable FAN Key disable Setpoint Key 03 disable FAN Key enable Setpoint Key 04 disable FAN Key disable Setpoint Key To disable means to switch back to FAN auto Setpoint offset zero and disable operation To enable means to make normal operation possible no action if unoccupied Unoccupied means Effective Unoccupied moon on continuously or Override Unocc...

Page 6: ... connected to the 2 LON terminals Via the 3 5 mm jack plug a PC connection can be established Order quantity set with 5 pieces Fig 9 T7460LONJACK Mounting Remove the setpoint wheel and put in the LonJack as shown in the following Fig 10 Mounting T7460 LONJACK T7560 Blinds Same material and color as housing for covering non operational buttons Order quantity set of 50 pieces ...

Page 7: ...T7560A B C DIGITAL WALL MODULES 95 7620 4 EN1B 0146GE51 R0303 7 ...

Page 8: ...d Control Solutions Honeywell AG Böblinger Straße 17 D 71101 Schönaich Phone 49 7031 63701 Fax 49 7031 637493 http europe hbc honeywell com Subject to change without notice Printed in Germany Manufacturing location certified to EN1B 0146GE51 R0303 95 7620 4 ...