![Honeywell T7350H Application Selection And Cross-Reference Manual Download Page 14](http://html.mh-extra.com/html/honeywell/t7350h/t7350h_application-selection-and-cross-reference-manual_154721014.webp)
I/R TIM
• Eliminates hard-to-find cables that connect a Palm
®
to the thermostat interface module.
• T7350 thermostat programming can be done on
the Palm and communicated via infrared to the I/R
TIM, which automatically transmits it to the T7350.
Simply download the T7350 program software at
customer.honeywell.com onto the Palm. Once the
T7350 is configured on the Palm, it can be beamed
via the infrared port to the I/R TIM.
• Most newer Palms are compatible.
• Programs can be saved on the Palm and beamed
again and again to other T7350s, saving time.
• Users can capitalize on more T7350 features that are
only accessible by using a Palm, including:
– 365-day holiday programming
– Configurable ramp rates
– Configurable PID loop tuning
– Configurable standby setpoints
– Configurable outdoor air temp lockout
– Configurable high and low discharge air limits
– Configurable dehumidification parameters
OS #: 50014064-001
Remote Room Temperature and
Discharge Air Sensors
• Full line of remote wall sensors.
• Gives user the option to have setpoint knobs/buttons,
override button or sensor only.
• Flush mount versions are available for high traffic
areas where protruding objects would get broken.
T7770A1006 — 20K Sensor only
T7770A3002 — 10K Averaging sensor
T7770B1046 — 20K Sensor with setpoint knob
T7770C1044 — 20K Sensor with setpoint knob
and override button
T7770D1000 — 20K Sensor with override button
T7771A1005 — 20K or 10K Sensor with setpoint
buttons and override button
C7772A1012 — 20K Flush mount sensor
C7041B2005 — 20K Discharge air sensor, 6" probe
C7041B2013 — 20K Discharge air sensor, 12" probe
Humidity Sensors
• Available in wall- or duct-mount applications.
– Allows for monitoring humidity via a wall sensor
or within the return air duct
• Available in different accuracies.
• 2%, 3% or 5% accuracy models for applications
requiring different levels of accuracy.
H7625A1008 — 2% RH accuracy wall-mount humidity
sensor with 20K room sensor
H7625B1006 — 2% RH accuracy duct-mount humidity
sensor with 20K room sensor
H7635A1006 — 3% RH accuracy wall-mount humidity
sensor with 20K room sensor
H7635B1004 — 3% RH accuracy duct-mount humidity
sensor with 20K room sensor
H7655A1001 — 5% RH accuracy wall-mount
humidity sensor
H7655B1009 — 5% RH accuracy duct-mount humidity
sensor with 20K room sensor
Accessories
14
Summary of Contents for T7350H