background image

T7079A,B SOLID STATE REMOTE TEMPERATURE CONTROLLERS

63-2572—04

2

ORDERING INFORMATION

When purchasing replacement and modernization products from your TRADELINE® wholesaler or distributor, refer to the 

TRADELINE® Catalog or price sheets for complete ordering number.

If you have additional questions, need further information, or would like to comment on our products or services, please write or 

phone:

1.

Your local Honeywell Automation and Control Products Sales Office (check white pages of your phone directory).

2.

Honeywell Customer Care

1885 Douglas Drive North

Minneapolis, Minnesota 55422-4386

In Canada—Honeywell Limited/Honeywell Limitée, 35 Dynamic Drive, Toronto, Ontario M1V 4Z9.

International Sales and Service Offices in all principal cities of the world. Manufacturing in Australia, Canada, Finland, France, 

Germany, Japan, Mexico, Netherlands, Spain, Taiwan, United Kingdom, U.S.A.

SPECIFICATIONS

Models:

T7079: On-off wall-mount control with one temperature input 

and one or two relay output stages. Differential range of 

1 to 30°F. Includes one sensor. See Table 1.

Table 1.  T7079 models.

Dimensions: 

See Fig. 1.

Fig. 1. Dimensions of T7079 in in. (mm).

Electrical Ratings:

Voltage Input: 24 Vac, 50/60 Hz (+10%, -15%), Class 2 

only

.

120/230 Vac, 50/60 Hz (+10%, -15%).

Power Consumption: 

See Table 2.

Table 2. Power consumption ratings.

Contact Ratings:

At 120 Vac: 1/2 hp, 9.8 FLA, 58.8 LRA.

At 230 Vac: 1/4 hp, 4.9 FLA, 29.4 LRA.

At 120/230 Vac: 125 VA pilot duty.

At 24 Vac (resistive): 8A.

Ambient Ratings:

Operating Temperature: -40

°

 to 140

°

F (-40

°

 to 60

°

C).

Storage Temperature: -40

°

 to 180

°

F (-40

°

 to 82

°

C).

Operating Humidity: 5% to 95% RH non-condensing.

Temperature Accuracy (at nominal voltage): 

In 77°F 

(25°C) ambient, nominal sensor value: ±2

°

F.

NOTE: Accuracy can vary based on deviation from nominal 

values of input voltage, operating ambient and 

sensor ambient.

Sensor: 

10k NTC, 400 ft maximum distance between sensor 

and electronic controller. See Table 3 for thermistor output.

Approvals:

Underwriters Laboratories, Inc.

Canadian Underwriters Laboratories.

CE.

Accessories:

107048 Heat Conduction Compound, 4 once.

107324A Bulb Holder, duct insertion.

121371A Copper Immersion Well.

121371E Stainless Steel Well.

32004800-001 10K NTC Sensor.

T7047C1090 Wall Mounted Sensor Case.

Voltage (in Vac) Setpoint Range in °F (°C)

24

120/230

-25 to 105

(-32 to 40)

100 to 240

(38 to 116)

T7079A1004

X

X

T7079A1012

X

X

T7079A1046

X

X

T7079A1053

X

X

T7079B1028

X

X

T7079B1036

X

X

T7079B1044

X

X

T7079B1051

X

X

STAGE1 STAGE2

POWER

2 (50)

2-7/16 (61)

1 (25)

2 (50)

4-1/2

(114)

7-3/16

(183)

2-7/16 (61)

M17560

Voltage

Hz

Nominal VA Maximum VA

24

50

5.6

6.2

60

5.5

6.1

120

50

7.7

8.5

60

5.6

6.2

230

50

5.0

6.1

60

2.9

4.7

Summary of Contents for T7079A

Page 1: ...tion to remote sensing is desired FEATURES Switch selection of heat or cool mode Temperature sensing up to 400 feet Does not require field calibration 10K NTC temperature sensor Wide setpoint temperature range LED annunciation for both power on and relay state Dual setpoint scale F and C Isolation transformer for 24 Vac input Single or Dual stage output Dual stage output models can be configured a...

Page 2: ... only 120 230 Vac 50 60 Hz 10 15 Power Consumption See Table 2 Table 2 Power consumption ratings Contact Ratings At 120 Vac 1 2 hp 9 8 FLA 58 8 LRA At 230 Vac 1 4 hp 4 9 FLA 29 4 LRA At 120 230 Vac 125 VA pilot duty At 24 Vac resistive 8A Ambient Ratings Operating Temperature 40 to 140 F 40 to 60 C Storage Temperature 40 to 180 F 40 to 82 C Operating Humidity 5 to 95 RH non condensing Temperature ...

Page 3: ...t 122 meters from the T7079 using standard AWG 18 2 unshielded wire The sensor may be attached to pipes in an immersion well in a wall mounted case or on a bulb holder NOTES For cable runs greater than 25 feet shielded cable is recommended Multiple sensors can be parallel series wired to sense average temperatures in large spaces See Fig 2 To maintain control accuracy the number of sensors wired p...

Page 4: ...e temperature sensor wiring near welding equipment 5 Make sure good mechanical connections are made to both the sensor and the control 6 Use 90 C copper wire Fig 5 Board layout for T7079 NOTES 1 The larger conduit knockout on the enclosure bottom is for line voltage applications 2 The smaller knockout on the enclosure bottom is for low voltage applications 3 The sensor knockout is at the enclosure...

Page 5: ...r heating the stage 2 setpoint is the stage 1 setpoint minus the inter stage differential When stage 2 is used for cooling the stage 2 setpoint is the stage 1 setpoint plus the inter stage differential Fig 8 Adjustments potentiometers and switches TWO STAGE HEAT 1 Set ST1 and ST2 switches to HEAT 2 Set interstage INTER and differential DIFF1 DIFF2 to desired settings 3 Position the setpoint knob a...

Page 6: ... controlled equipment Keep in mind that based on the terminal board labels the stage 1 relay is J4 the stage 2 relay is J5 With the controller installed and wired use the following procedure 1 Verify all settings 2 Apply power 3 Check for proper equipment response a Cooling applications turn the setpoint knob counterclockwise until the stage LED lights b Heating applications turn the setpoint knob...

Page 7: ...T7079A B SOLID STATE REMOTE TEMPERATURE CONTROLLERS 7 63 2572 04 ...

Page 8: ...Limited Honeywell Limitée 1985 Douglas Drive North 35 Dynamic Drive Golden Valley MN 55422 Toronto Ontario M1V 4Z9 customer honeywell com T7079A B SOLID STATE REMOTE TEMPERATURE CONTROLLERS U S Registered Trademark 2009 Honeywell International Inc 63 2572 04 K K Rev 07 09 ...

Reviews: