Honeywell Switches Brochure Download Page 4

1.47” REF.

The 5000 Series switch is specifically 
designed to stand up to extended duty 
applications.  This switch is factory set 
but capable of field adjustment. It 
features a Kapton diaphragm for 
compatibility with a wide variety of 
fluids, and various terminations 
including a Metri-Pack connector that 
forms a tight seal when connected.  
Among the outstanding design benefits 
are its durable construction, compact 
size, and enhanced set point integrity.

2.3” REF.

1.47” REF.

5000 Series Switch 

with Screw Terminals

5000 Series Switch 

with Metri-Pack Terminal

Set Points from 0.5 to 150 psi

5000 Series

 Extended Duty Pressure Switch With Direct Action Blade Contacts

Switch Boot P/N 79380

for Vacuum and Pressure

NOTE:

 OPERATING MEDIA (PRESSURE SWITCH)

The pressure switch is designed to operate with air, 

motor oils, transmission oils, jet fuels and other similar 

hydrocarbon media. 

4

Standard Specifications

Type:

   

Direct action 

 

blade contact

Contacts:

    Silver alloy, 

 

gold plated

Set Point:

    Factory set 

 

from 0.5 to 150 PSI

Operating Pressure:

150 PSI for 0.5-24 PSI set point range, 
250 PSI for 25-150 PSI set point range 

Proof

 

Pressure:

 500 PSI

Burst

 

Pressure:

 750 PSI for 0.5-24 PSI 

 

set point range

 

1250 PSI for 25-150 PSI  

 

set point range.

Ratings:

Resistive:  

15  AMP- 

6   VDC

 

8  AMP- 

12   VDC

 

4  AMP- 

24   VDC

Inductive:

 

1  AMP-  120   VAC

 

0.5  AMP-  240   VAC

Diaphragm:

  Polyimide film 

Temperature 
Range:

  

-40° F to + 250° F

Connector:

   

1/8 

-27 NPT male thread

Terminals:

   #8-32 screws, 

 

1/4” blade, 

  

280 Series Metri-Pack

Circuitry:

  

SPST-N.O., N.C., 

 

1 circuit adjustable dual    

 

circuit, or 2 circuits  

 

 

adjustable dual circuit. 

 

Also available are  

 

 

N.O./N.O. dual circuit

 

and N.C./N.C. dual circuit.

Base:

  

Plated Steel

Cover:

  

Glass reinforced polyester

Options:

  

Brass, plastic or stainless    

 

steel base; various base    

 

connector thread sizes;  

 

 

wire leads (potted & sealed).

2.9” REF.

Summary of Contents for Switches

Page 1: ...Sensing and Control ...

Page 2: ...lled model shop certified lab and engineering staff can work with you through the design phase prototype stage all the way through to the testing phase And if time is a crucial factor rapid prototyping technology can now allow us to provide you with a sample in days WARNING Suitability of application is responsibility of user Extreme heat and vibration should be avoided at mounting points such as ...

Page 3: ... systems The switch s physical appearance is similar to our 5000 Series switches with a height of only 2 3 approx and a diameter of 1 47 In comparison to our 5000 Series Switch the burst rating has significantly increased from 1250 psi to over 4000 psi on the new design Specifications Type Direct action blade contact Contacts Silver alloy gold plated Set Point Range 10 400 PSI Operating Pressure 5...

Page 4: ... motor oils transmission oils jet fuels and other similar hydrocarbon media 4 Standard Specifications Type Direct action blade contact Contacts Silver alloy gold plated Set Point Factory set from 0 5 to 150 PSI Operating Pressure 150 PSI for 0 5 24 PSI set point range 250 PSI for 25 150 PSI set point range Proof Pressure 500 PSI Burst Pressure 750 PSI for 0 5 24 PSI set point range 1250 PSI for 25...

Page 5: ... 100 PSI Notes 1 The N C circuit is the reference circuit for the dual circuit switch the normally open circuit is not adjusted The expected dead band between the N C N O circuit is shown in the chart below For applications requiring the normally open circuit as the reference circuit the N C circuit is not adjusted 2 Switch may be adjusted so that A N C circuit opens before N O circuit closes B N ...

Page 6: ... max Burst Pressure 150 PSI Ratings Resistive 15 AMP 6 VDC 8 AMP 12 VDC 4 AMP 24 VDC Inductive 1 AMP 120 VAC 0 5 AMP 240 VAC Diaphragm Fluorosilicone elastomer Temperature Range 40 F to 250 F Connector 1 8 27 NPT male thread Terminals 8 32 screws 1 4 blade 280 Series Metri Pack Circuitry SPST N O N C Base Brass Cover Glass reinforced polyester Options Various base connector thread sizes wire leads...

Page 7: ...80 see photo on page 4 Note The N C circuit is the reference circuit for the dual circuit switch the normally open circuit is not adjusted For applications requiring the normally open circuit as the reference circuit the N C circuit is not adjusted Specify 1 Set point 2 Actuate on increasing or decreasing pressure 3 SPST N O or N C SPDT 1 47 REF Piston Switch with Standard Terminal Contact Setting...

Page 8: ... 6 VDC 8 AMP 12 VDC 4 AMP 24 VDC Inductive 1 AMP 120 VAC 0 5 AMP 240 VAC Dry circuits Diaphragm Silicone rubber Temperature Range 40 F to 250 F Connector 1 8 27 PTF SAE short male thread Terminals 8 Wire leads 18 ga Circuitry SPST N O or N C SPDT Base Brass Housing Die cast zinc Options Silver contacts silver soldered base fluorosilicone rubber diaphragm Terminations Wire leads with wide selection...

Page 9: ...nd under all operating conditions it boasts an excellent response time Like the Series III the Series V exclusive snap switch has an adjustable differential low contact resistance wiping action fast transfer time and gold over silver contacts This switch is beneficial where hysteresis fast transfer time and low contact resistance are vital Standard Specifications Type Snap action switch Set Point ...

Page 10: ...closed circuits System Pressure Vacuum This is the normal pressure vacuum that would be present at the switch actuator This value is important in order to apply the proper switch configuration Even though the set point may be relatively low the system pressure would continue to be applied to the switch actuator in most cases Proof Pressure This specification is the maximum over pressure condition ...

Page 11: ...ized test equipment are utilized to eliminate scrap and rework Kanban cards are used to pull raw material and piece parts through the factory Bar coding and electronic data interchange EDI are available MANUFACTURING 11 Honeywell s Springfield and Spring Valley Illinois facilities manufacture a broad range of electro and electronic mechanical products that include Hobbs hour meters pressure and va...

Page 12: ... of merchantability and fitness for a particular purpose While we provide application assistance personally through our literature and the Honeywell web site it is up to the customer to determine the suitability of the product in the application Specifications may change at any time without notice The information we supply is believed to be accurate and reliable as of this printing However we assu...

Reviews: