background image

 

Honeywell Process Solutions 

1860 West Rose Garden Lane 

34-TT-25-19, Rev.1 

Phoenix, Arizona 85027 

July 2017 

www.honeywellprocess.com

 

2017 Honeywell International Inc.

 

  

 

 

Sales and Service 

For application assistance, current specifications, pricing, or name of the nearest 
Authorized Distributor, contact one of the offices below. 
 

ASIA PACIFIC 

(TAC)

  

Australia 

Honeywell Limited,  Phone: +(61) 7-3846 1255, FAX: +(61) 7-3840 6481 

Toll Free 1300-36-39-36, Toll Free Fax: 1300-36-04-70 

China 

– PRC – Shanghai, 

Honeywell China Inc. Phone: (86-21) 5257-4568,  

Fax: (86-21) 6237-2826 

Singapore, 

Honeywell Pte Ltd. Phone: +(65) 6580 3278. Fax: +(65) 6445-3033 

South Korea, 

Honeywell Korea Co Ltd. Phone:+(822)799 6114. Fax:+(822) 792 9015 

EMEA, 

Phone: + 80012026455 or +44 (0)1202645583. FAX: +44 (0) 1344 655554 

Email: (Sales)

 

[email protected]

  

or (TAC)

 

[email protected]

 

AMERICAS 

Honeywell Process Solutions, Phone: 1-800-423-9883,  

Or 1-800-343-0228. Email: (Sales)

 

[email protected]  

or (TAC)

  

[email protected]

 

 

 

 

 

WARRANTY/REMEDY 

Honeywell warrants goods of its manufacture as being free of defective materials and 
faulty workmanship. Contact your local sales office for warranty information.  
If warranted goods are returned to Honeywell during the period of coverage, Honeywell 
will repair or replace without charge those items it finds defective. The foregoing is 
Buyer's sole remedy and is 

in lieu of all other warranties, expressed or implied, 

including those of merchantability and fitness for a particular purpose

Specifications may change without notice. The information we supply is believed to be 
accurate and reliable as of this printing. However, we assume no responsibility for its use. 

While we provide application assistance personally, through our literature and the 
Honeywell web site, it is up to the customer to determine the suitability of the product 
in the application. 

 

 
 
 

Summary of Contents for SmartLine STT700 DE

Page 1: ...pyrights Notices and Trademarks Copyright 2017 by Honeywell Revision 1 May 2017 Trademarks SFC SmartLine STT700 are U S registered trademarks of Honeywell Inc HART is a trademark of FieldComm Group Revision history Rev 1 July 2017 1st release References The following list identifies all documents that may be sources of reference for material discussed in this publication Document Title Document ST...

Page 2: ...700 Temperature Transmitter HART left DE right 3 Figure 2 DIN Rail Mounting 4 Figure 3 Wall Mounting Dimensions 5 Figure 4 Pipe Mounting Dimensions 5 Figure 5 Spring Loading and Sensor Assembly 6 Figure 6 STT700 HART Transmitter Operating Ranges 7 Figure 7 STT700 DE Transmitter Operating Ranges 7 Figure 8 STT 700 Terminal connections 8 Figure 9 HART DE Input Wiring Diagram for single sensor connec...

Page 3: ...ices e g pumps Valve Cavitation In preparation for post installation processes refer to the MC Toolkit User Manual Document 34 ST 25 50 MCT404 for battery conditioning and device operation and maintenance information FEATURES AND OPTIONS As shown in Figure 1 the STT700 is packaged in a single module The elements in this module are connected to the process sensors measure the process variables resp...

Page 4: ...crewed to the bottom lugs of the module Figure 2 DIN Rail Mounting The DIN Rail needs to be connected to Earth Ground refer to STT700 SmartLine transmitter user s manual 34 TT 25 17 Uninstalling Installing EU Meter from Housing EU Meter 1 Remove the EU METER from the mounting bracket 2 Unfasten the 2 mounting screws 3 Remove the bracket To put the EU meter back follow the above sequence in the rev...

Page 5: ...r Field Mount Housing without Meter Field Mount Housing with and without Meter Figure 3 Wall Mounting Dimensions Field Mount Housing with Meter Field Mount Housing without Meter Field Mount Housing with and without Meter Figure 4 Pipe Mounting Dimensions Table 2 Mounting Dimensions Dimensions Aluminum field mount housing A B Without integral meter 70 mm 2 76 inch 120 8 mm 4 76 inch With integral m...

Page 6: ...ssembly together Guide the sensor assembly through the housing sensor entry and screw down the 33 mm screws until the limit is reached as the sensor presses against the bottom of thermowell For wall or 2 pipe mounting the temperature sensor can be remote from the STT700 field mount housing or integral to the housing For remote installations the sensor wiring should be run in shielded twisted pair ...

Page 7: ... Summary The transmitter is designed to operate in a two wire power current loop with loop resistance and power supply voltage within the HART and DE operating ranges shown in Figure 6 Figure 6 STT700 HART Transmitter Operating Ranges Figure 7 STT700 DE Transmitter Operating Ranges ...

Page 8: ...or use in areas that are highly susceptible to lightning strikes As noted above the loop power wiring shield should only be connected to earth ground at the power supply end Wiring must comply with local codes regulations and ordinances Grounding may be required to meet various approval body certification for example CE conformity Refer to the STT700 SmartLine Transmitter User s Manual 34 TT 25 17...

Page 9: ...AWG or 8 37mm2 bare or green covered wire for this connection For ungrounded thermocouple mV RTD or ohm inputs connect the input wiring shield s to the same earth ground connection For grounded thermocouple inputs connect the internal ground connection shown in Figure 8 to the same earth ground as used by the thermocouple As noted above the loop power wiring shield should only be connected to eart...

Page 10: ... keep covers tight while the Transmitter is energized Disconnect power to the Transmitter in the non hazardous area prior to removing end caps for service When installed as non incendive equipment in a Division 2 hazardous location disconnect power to the Transmitter in the non hazardous area or determine that the location is non hazardous before disconnecting or connecting the Transmitter wires T...

Page 11: ...otection against surges such as those generated by lightning strikes The lightning protector mounts right on the top of the STT700 terminal block providing easy field wiring and also protection for the EU meter if used For more details refer to STT700 SmartLine temperature transmitter user s manual 34 TT 25 17 Figure 11 Lightning Protector Dimensions ...

Page 12: ...er module terminal block and the transmitter output screws and fix mechanically the device Attach the grounding wire to the ground screw in the housing Connect a wire from the transmitter enclosure to local earth ground Use size 14 AWG or 2 0mm2 bare or green covered wire If an EU meter is used wire according to Figure 13 Connect the 4 20mA loop to the and terminal screws of the surge protection a...

Page 13: ... STT700 Quick Start Installation Guide 13 Figure 13 Installation with EU Meter For start up operation including configuration maintenance and calibration refer to the STT700 Transmitter User s manual 34 TT 25 17 ...

Page 14: ... com AMERICAS Honeywell Process Solutions Phone 1 800 423 9883 Or 1 800 343 0228 Email Sales ask ssc honeywell com or TAC hfs tac support honeywell com WARRANTY REMEDY Honeywell warrants goods of its manufacture as being free of defective materials and faulty workmanship Contact your local sales office for warranty information If warranted goods are returned to Honeywell during the period of cover...

Reviews: