Honeywell SILENT KNIGHT SK-FML Installation Instructions Download Page 4

SK-FML/SK-FSL Fiber Option Modules Installation Instructions

4

P/N LS10178-001SK-E-A

Table 4.4.2 lists the SK-FSL LED Indicators.

S

ection 5:Reference Documentation

Table 5.1 lists the UL-Controlled documentation 
assigned to the Silent Knight Systems. If you require 
detailed installation instructions on cabinetry, wiring 
and specifications, you can download the following 
UL-Controlled documents from the ESD site on the 
Silent Knight Website (www.silentknight.com).

LED #  Name  Color 

Description

1

TX

Green Lights while data is 

transmitted on the Repeater.
When activity is detected, the 
TX light flickers and turns ON.
If no activity is detected, the 
TX light turns OFF.

2

RX

Green Lights while data is received 

on the Repeater. 
When activity is detected, the 
RX light flickers and turns ON.
When no activity is detected, 
the RX light turns OFF.

Table 4.4.2 SK-FSL LED Indicators

Part Number 

Title

LS10143-001SK-E IFP-2100/ECS Installation and    

Operation Manual

LS10144-001SK-E 6820-EVS Installation and 

Operation Manual

LS10145-001SK-E IFP-300/ECS Installation and 

Operation Manual

LS10146-001SK-E 6808 Installation and Operation 

Manual

LS10147-001SK-E IFP-75 Installation and 

Operation Manual

LS10148-001SK-E 6700 Installation and Operation 

Manual

LS10169-001SK-E ECS-NVCM Installation Sheet

LS10171-001SK-E SK-NIC Installation Sheet

Table 5.1 Reference Documentation

firealarmresources.com

Summary of Contents for SILENT KNIGHT SK-FML

Page 1: ...e Figure 1 1 SK FML Circuit Board SK FSL Fiber Optic Single Mode Transmitter The SK FSL is a fiber module that is used as one channel to transmit or receive communications with the ECS NVCM Network Voice Control Module or SK NIC Network Interface Card It allows the single mode fiber to network between the SK FSL module boards Figure 1 2 shows the SK FSL fiber module Figure 1 2 SK FSL Circuit Board...

Page 2: ...s static shield bag observing proper static protection measures 2 Visually inspect the unit for damage If any components are damaged notify the shipping carrier immediately Report missing components to the Silent Knight Customer Service 3 Use the Hardware Kit provided with the unit 4 Plug the Fiber Module 1 into P6 of the ECS NVCM or SK NIC circuit as shown in Location 1 in Figure 3 2 1 and Figure...

Page 3: ...tput power for the transmitting fiber See Table 4 2 2 SW1 4 Not used P1 Plugs onto P5 Port 1 or P6 Port 2 of the ECS NVCM or SK NIC NOTE Use standard ST connector fiber optic cable multi mode up to 200 µ optimized for 62 5 125 µ Signal loss up to 8dB maximum between nodes Table 4 2 1 SK FML Terminal Wiring Designations J2 J1 FIBER IN FIBER OUT SW1 1 SW1 2 SW1 3 Drive Current OFF OFF OFF 10 mA OFF ...

Page 4: ... flickers and turns ON If no activity is detected the TX light turns OFF 2 RX Green Lights while data is received on the Repeater When activity is detected the RX light flickers and turns ON When no activity is detected the RX light turns OFF Table 4 4 2 SK FSL LED Indicators Part Number Title LS10143 001SK E IFP 2100 ECS Installation and Operation Manual LS10144 001SK E 6820 EVS Installation and ...

Reviews: