Figure 4a: Installation of IDP-Monitor-10 module in a  

rear chassis position, method two

Step 1:  Insert the bottom edge of the IDP-Monitor-10  

 

module down into a rear slot of the chassis.

Step 2:  Carefully swing the upper edge of the board  

 

towards the back of the chassis until it touches  

 

the short standoff attached to the chassis.

Step 3:  Align the long standoff with the short stand  off  

 

and tighten.

2

3

1

Figure 4b: Installation of IDP-Monitor-10 module in  

front chassis position

Step 1:  Insert the bottom edge of the IDP-Monitor-10  

 

module down into a front slot of the chassis.

Step 2:  Carefully  swing  the  upper  edge  of  the  board  

 

towards the back of the chassis until it touches  

 

the 1

1

4

˝ (31.75mm) standoffs installed on the  

 

rear module.

Step 3:  Align two 4-40 screws with the two standoffs  

 

and tighten.

Step 4:  Address  and  wire  the  modules  according  to  the  

 

instructions in this manual.

INSTALLATION STEPS

1.  Cabinet Mounting

 

In  a  clean,  dry  area,  mount  the  backbox  using  the 
four holes provided in the back surface of the cabinet 
(Figure 2).

Figure 2: Typical mounting hole locations

2. 

Module Installation

 

There are two methods for installing a module in the 
rear position of a chassis. Method one is for installa-
tion of a rear module only, when no module will be in-
stalled in front of it. Refer to Figure 3 for instructions. 
Method two is for installation of a rear module when 
another module will be installed in the chassis position 
in front of it.  Refer to Figures 4a and 4b for method 
two. All  necessary  screws  and  standoffs  are  supplied 
with the modules.

2

3

1

Figure 3: Installation of rear module only, method one

Step 1:  Insert the bottom of the IDP-Monitor-10 module  

 

down into a rear slot on the chassis. 

Step 2:  Carefully swing the upper edge of the board  

 

back towards the back of the chassis until it   

 

touches the two standoffs.

Step 3:  Align two 4-40 screws with the two standoffs  

 

and tighten.

Step 4:  Address and wire the modules according to the  

 

instructions in this manual.

The steps in Figures 4a and 4b describe and illustrate mod-
ule installation when the rear chassis position and the posi-
tion in front of it will be filled.  Front position installation 
is possible only if the rear position is filled with a module.

K200-14-00 

I56-2731-003

C0237-00

C0235-00

C0225-00

Backbox
Mounting
Holes

C0226-00

firealarmresources.com

Summary of Contents for SILENT KNIGHT IDP-Monitor-10

Page 1: ...w the rear IDP Monitor 10 module positions so that all of the status indicators are visible For cabinet dimensions refer to the IDP ACB instruction manual K200 14 00 1 I56 2731 003 INSTALLATION AND MAINTENANCE INSTRUCTIONS IDP Monitor 10 Ten Input Monitor Module SPECIFICATIONS Normal Operating Voltage 15 32 VDC Stand By Current 3 5 mA Alarm Current 55 mA assumes all ten LEDs solid on Temperature R...

Page 2: ...e locations 2 Module Installation There are two methods for installing a module in the rear position of a chassis Method one is for installa tion of a rear module only when no module will be in stalled in front of it Refer to Figure 3 for instructions Method two is for installation of a rear module when another module will be installed in the chassis position in front of it Refer to Figures 4a and...

Page 3: ...terference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television rece...

Page 4: ...OT mix fire alarm initiating and supervisory devices on the same initiating device circuit Install contact closure devices per manufacturer s installation instructions BASE ADDRESS TO NEXT DEVICE STATUS INDICATORS IDC ADDRESS 0 1 2 3 4 5 6 7 8 9 IDC ADDRESS IDC ADDRESS IDC ADDRESS IDC ADDRESS SLC FROM PANEL OR PREVIOUS DEVICE CONNECT MODULES TO LISTED COMPATIBLE SILENT KNIGHT CONTROL PANELS ONLY S...

Reviews: