background image

 
4-3-2. Zoom In/Out 
  Twist the joystick count clockwise to zoom out,  clockwise to zoom in. 

Zoom speed is proportional to rotation of the joystick.  

 
4-3-3. Manual Focus 

Press the key “FAR” or “NEAR” to manually focus. When the zoom handle of the joystick is 

twisted slightly, the camera will return to Auto Focus mode. 

 
 

 

4-3-4. Manual Iris 

Press the key “OPEN” or “CLOSE” to manually open or close the iris. Move the joystick 

slightly to return to Auto Iris Mode. 
 
4-3-5. Setting Zoom Camera 

-

  Pressing the MENU key and then SETUP MENU is displayed on the screen. 

-

  Select item of SETUP MENU using up/down joystick. 

-

  Move joystick Left/Right to change value of selected item.  

-

  Press the MENU key again. SETUP MENU is disappeared,  

         “SAVE?” or “QUIT?” is displayed at center of screen. 
         If there is no change of adjustment state of Camera,   
         “QUIT?” is showed, else “ SAVE?” is showed.  
        

 “QUIT?” : quit SETUP MENU without saving changed value. 

        

 “SAVE?” : quit SETUP MENU with saving changed value.

 

 
4-3-6. Setting Preset, Tour, Pattern, Auto Scan 

Set Preset, Tour, Pattern, Auto Scan by pressing MENU and selecting item of menu. 

 

Æ

More detail refer to the manual of ScanDome II. 

 

*Setting Preset of Zoom camera(HDC-655, GC-655, GC-755) 

-Zoom in/out to watch desired view.  

-Press No and HOME  to store preset view. 

  

4-3-7. Call Preset, Tour, Pattern, Auto Scan 

To call the number of the desired Preset, Tour, Pattern, Auto Scan, enter the number and 

press key “PST”, “TOUR”, “PTRN”, “SCAN”. 

                
 
 

4-3-8. Global 
  

It is possible to cause all cameras to move to preset positions simultaneously. 
Enter desired global number and press key”GLB”. 

.

 

 

4-3-9. Relay ON/OFF 

ON: Press 111~114 and “ENT” to turn on relay of in the ScanDome. 
OFF: Press 111~114 and “CLR” to turn off relay of in the ScanDome. 
 

Summary of Contents for Scan Dome ll HTX-2500

Page 1: ...ScanDome llTM Controller HTX 2500 Please read this manual thoroughly before use and keep it handy for future reference Operation Programming Manual ...

Page 2: ...Warnings This video monitor is equipped with a three wire grounding type plug a plug having a third grounding pin This plug will only fit into a grounding type power outlet This is a safety feature If you are unable to insert the plug into the outlet contact your electrician to replace your obsolete outlet Do not defeat the safety purpose of the grounding type plug POWER CORDS Do not allow anythin...

Page 3: ... 5 4 2 Select Camera Type 6 4 3 Operation 6 4 3 1 Pan Tilt 7 4 3 2 Zoom In Out 7 4 3 3 Manual Focus 7 4 3 4 Manual Iris 7 4 3 5 Setting Zoom camera 7 4 3 6 Setting Preset Tour Pattern Auto Scan 7 4 3 7 Call Preset Tour Pattern Auto Scan 7 4 3 8 Global 7 4 3 9 Relay On Off 8 5 Spesifications 9 ...

Page 4: ...cation line RS 485 3 3 The BNC cable to the dome camera housing and appropriate switching device if needed 3 4 Turn on camera and receiver unit power 3 5 Connect 12 VDC to the junction box 3 6 Connect the 8 pin multi wire cable to the controller HTX 2500 and the junction box 3 7 Connect the 8 pin multi wire cable to the master and slave controller if needed RS 485 HRX 2000 GC 655 Or GC 755 P T Dri...

Page 5: ...word is 8888 4 1 2 After entering password the user can select the controller mode Press key ENT Skip Maintain current mode Press Key 1 Master Mode Press Key 2 Slave Mode INPUT PASSWORD INPUT FIRMWARE VERSION VER X XX ScanDome Controller INPUT PASSWORD CORRECT PASSWORD CURRENT STATUS MASTER MODE CONFIG ENT SKIP MASTER 1 SLAVE 2 ...

Page 6: ... or 3 according to camera type and ENT 1 SD ScanDome II Receiver Unit HRX 2000 2 X23 x23 AF Zoom Camera GC 655 x23 AF Dome Camera HDC 655 3 X25 x25 AF Zoom Camera GC 755 Step4 Repeat Step 1 3 if needed Please set camera address refer to the manual 4 3 Operation First you must input address of desired camera and then press ENT 4 3 1 Pan Tilt Move joystick up down left right to control the camera di...

Page 7: ...ter of screen If there is no change of adjustment state of Camera QUIT is showed else SAVE is showed QUIT quit SETUP MENU without saving changed value SAVE quit SETUP MENU with saving changed value 4 3 6 Setting Preset Tour Pattern Auto Scan Set Preset Tour Pattern Auto Scan by pressing MENU and selecting item of menu ÆMore detail refer to the manual of ScanDome II Setting Preset of Zoom camera HD...

Page 8: ...8 5 Specifications Communication RS 485 Supply Voltage 12 VDC 600mA Operation Temperature 0 o C 50 o C 32 o F 122 o F Operation Humidity 0 90 RH Storage Temperature 20o C 60o C 4o F 140o F ...

Page 9: ... Co Ltd Address 17F Kukje Center Building 191 Hankangro 2ga Yongsan gu Seoul 140 702 Korea Phone 82 2 799 6117 Fax 82 2 749 6119 http www honeywell co kr cctv E mail cctv honeywell com security honeywell com Memo ...

Page 10: ...10 ...