Honeywell RTH2520B Installation And User Manual Download Page 2

RTH2520

      69-1867ES—05     03-11     2/8

2.3.1 2-wire Heating

2.3.2 2-wire Cooling

2.3.3 3-wire Heating

2.3.4 3-wire Cooling

2.3.5 4-wire Heating and Cooling

2.3.6 5-wire Heating and Cooling

Note

: Remove the red jumper wire between terminals Rc and Rh.

2.4 Setting JP2 Jumper

The jumper specifies how the fan will operate
when it is placed in automatic mode (see sec-
tion 3.2).

2.5 Installing the Batteries

Gently pull out the battery cover. 

Install the batteries as shown. Observe the polarity.

Reinstall the battery cover. You will hear a clicking sound.

After the batteries are installed, the thermostat performs a
sequence of tests for approximately 5 seconds.
Afterwards, the screen displays the actual
temperature. It is normal that the displayed
temperature be higher than the ambient
temperature if you are holding the thermo-
stat. Once installed on the wall, the thermostat will display the ambi-
ent temperature. By default, the setpoint is 70°F (21°C).
The time and day settings flash to indicate that they must be set
(see section 5.1).

2.6 Completing the Installation

Once the baseplate and the batteries are installed, mount the 
thermostat on the baseplate.

Secure the thermostat using the locking screw and install the 
faceplate.

Apply power back to the system.

3.1 System Operating Mode

Use this selector switch to place the system in Heat-
ing mode (HEAT) or Cooling mode (COOL), or to set
both modes to Off.

Note

: When you place the thermostat in Cooling mode, you might

need to wait up to five minutes before cooling can start. This is a
safety feature for the compressor.   will flash on the screen during
the delay.

Heat relay

Jumper

Cool relay

Jumper

Fan relay

Heat relay

Jumper

Cool relay

Fan relay

Jumper

Heat relay

Cool relay

Fan relay

Jumper

Fan relay

Cool relay

Heat relay

HG

Leave the jumper in this position if you 
have a gas or oil heating system.

HE

Move the jumper to this position if you 
have an electric heating system.

3. Basic Functions

JP2 jumper

Summary of Contents for RTH2520B

Page 1: ...nd a pencil to prevent them from falling into the wall If the hole in the wall is too big insulate it using a non flammable material in order to avoid air draughts behind the thermostat 2 2 Installing the New Baseplate For a new installation choose a location approximately 5 feet 1 5 m above the floor and on an inside wall Avoid draughty areas top of staircase air outlet etc dead air spots behind ...

Page 2: ...isplay the ambi ent temperature By default the setpoint is 70 F 21 C The time and day settings flash to indicate that they must be set see section 5 1 2 6 Completing the Installation Once the baseplate and the batteries are installed mount the thermostat on the baseplate Secure the thermostat using the locking screw and install the faceplate Apply power back to the system 3 1 System Operating Mode...

Page 3: ...nd date see sec tions 5 1 and 5 2 However the temperature and program settings are saved and do not need to be re entered Warning Before removing the batteries place the system switch on the thermostat to Off Otherwise the heating cooling unit might still be running even after the batteries are removed To access the configuration menu press the backlight button for 3 seconds To go to the next para...

Page 4: ...rchase by the consumer If at any time dur ing the warranty period the product is determined to be defective or malfunc tions Honeywell shall repair or replace it at Honeywell s option If the product is defective i return it with a bill of sale or other dated proof of purchase to the place from which you purchased it or ii call Honeywell Customer Care at 1 800 468 1502 Customer Care will make the d...

Page 5: ... que caigan en el hueco de la pared Si el hueco de la pared es muy grande aíslelo con un material no inflamable para evitar que haya corrientes de aire detrás del termostato 2 2 Instalación de la nueva placa de base Para una instalación nueva elija una ubicación que esté aproxima damente 5 pies 1 5 m sobre el suelo y sobre una pared interior Evite áreas donde haya corrientes de aire parte superior...

Page 6: ...ed tiene el termostato en las manos El termostato mostrará la temperatura ambiente cuando esté colocado en la pared Por defecto el punto de referencia es 70 ºF 21 ºC Las configuraciones de fecha y hora parpadearán para indicar que deben ajustarse vea la sección 5 1 2 6 Finalización de la instalación Una vez que la placa de la base y las baterías estén coloca das monte el termostato sobre la placa ...

Page 7: ...n mes aún cuando el icono no haya aparecido en la pantalla Una vez que haya reemplazado las baterías vuelva a ajustar la hora el día de la semana y la fecha vea la sección 5 1 y 5 2 Sin embargo la temperatura y las configuraciones de los programas se guardan en la memoria y no es necesario volver a ingresarlos Advertencia Antes de extraer las baterías coloque el interruptor del sistema en la posic...

Page 8: ...volátil Dimensiones 5 x 3 x 1 pulgadas 127 mm x 75 mm x 28 mm Honeywell garantiza por un período de un 1 año a partir de la fecha de compra por el consumidor que este producto sin incluir las baterías no presentará defectos en los materiales ni en lo referente a la mano de obra en condiciones normales de uso y de servicio Si en cualquier momento durante el período de vigencia de la garantía se det...

Reviews: