background image

RTH230B

      69-1800—03     03-11     2/4

2.3.1 2-wire Heating

2.3.2 2-wire Cooling

2.3.3 3-wire Heating

2.3.4 3-wire Cooling

2.3.5 4-wire Heating and Cooling

2.3.6 5-wire Heating and Cooling

2.4 Setting J2 Jumper

The jumper defines the fan operation when the fan is placed in auto-
matic mode.

2.5 Installing the Batteries

Pull out the battery cover. 

Install the batteries as shown. Observe the polarity.

Reinstall the battery cover. You will hear a clicking sound.

After the batteries are installed, the thermostat performs a series of
tests for approximately 5 seconds.
Afterwards, the screen displays the actual
temperature. It is normal that the displayed
temperature be higher than the ambient
temperature if you are holding the thermo-
stat. The thermostat will display the ambient temperature once it is
installed on the wall. By default, the setpoint is 70°F (21°C).

2.6 Completing the Installation

Once the baseplate and the batteries are installed, mount the 
thermostat on the baseplate.

Secure the thermostat using the locking screw and install the 
faceplate.

Apply power back to the system.

3.1 System Operating Mode

Use the selector switch to place the system in Heating
mode (HEAT) or Cooling mode (COOL), or to set the
system off.

Note

: When you place the thermostat in Cooling mode, you might need to

wait up to five minutes before cooling can start. This is a safety feature for
the compressor. 

 will flash on the screen until cooling can start again.

Heat relay

Cool relay

Fan relay

Heat relay

Cool relay

Fan relay

Heat relay

Cool relay

Fan relay

Fan relay

Cool relay

Heat relay

HE

Use this setting if you have an electric furnace. In 
this setting, when the fan is placed in automatic 
mode, it works only when heating or cooling is 
activated.

HG

Use this setting if you have a gas or fuel oil fur-
nace. In this setting, when the fan is placed in 
automatic mode, it works as follows:

When the thermostat is placed in cool mode,
the fan works only when cooling is activated.

When the thermostat is placed in heat mode,
the fan is controlled by the furnace fan control
circuitry.

3. Basic Functions

J2 jumper

Summary of Contents for RTH230B - 5-2 Day Programmable Thermostat

Page 1: ... from falling into the wall If the hole in the wall is too big insulate it using a non flammable material in order to avoid air draughts behind the thermostat 2 2 Installing the New Baseplate For a new installation choose a location approximately 5 feet 1 5 m above the floor and on an inside wall Avoid draughty areas top of staircase air outlet etc dead air spots behind doors direct sunlight or ar...

Page 2: ...nt the thermostat on the baseplate Secure the thermostat using the locking screw and install the faceplate Apply power back to the system 3 1 System Operating Mode Use the selector switch to place the system in Heating mode HEAT or Cooling mode COOL or to set the system off Note When you place the thermostat in Cooling mode you might need to wait up to five minutes before cooling can start This is...

Page 3: ...see section 5 1 However the temperature and program settings are saved and do not need to be re entered Warning Before removing the batteries place the system switch on the thermostat to Off Otherwise the heating cooling unit might still be running even after the batteries are removed To access the configuration menu press both buttons simultaneously for 3 seconds To go to the next parameter menu ...

Page 4: ...ne 1 year from the date of purchase by the consumer If at any time dur ing the warranty period the product is determined to be defective or malfunc tions Honeywell shall repair or replace it at Honeywell s option If the product is defective i return it with a bill of sale or other dated proof of purchase to the place from which you purchased it or ii call Honeywell Customer Care at 1 800 468 1502 ...

Reviews: