Honeywell RK-MCU Product Instructions Download Page 7

 

 

 

Product Overview 

RK-MCU  Master  Control  Unit  is  the  central  management  device  of  the 
INTEVIO PA system, which is used to manage and monitor all devices and 
perform  various  operations.  RK-MCU  is  integrated  with  audio  storage, 
broadcast, zone control, monitor, timing control, and fault diagnosis. Built-in 
500W digital power amplifier can drive a maximum 8 loudspeaker zones to 
meet requirements for small applications. It can also be connected to zone 
expanders  to  increase  system  capacity  for  the  requirements  of  large 
applications as well. 

 

Product Features 

 

Manage all devices in the system, used for public address and 
emergency broadcast. 

 

View system status and set the parameters via LCD screen. 

 

Supports both single channel mode and dual channel mode. 

 

Maximum 8 loudspeaker zones can be connected, with a maximum 
power rating of 500W for each zone. 

 

Built-in 500W Class-D power amplifier.  

 

Supports external power amplifiers. 

 

Flexible power amplifier redundancy. One spare amplifier can back up 
all amplifiers in the system. 

 

Built-in 1GB Flash memory and 8GB SD card, which can be used to 
store audio files, recording files, configuration data and log files, etc. 

 

Two auxiliary inputs and one MIC/LINE input. 

 

Optional PTT microphone used for live broadcast. 

 

Digital volume control, easy to set input and output volume. 

 

255 broadcast priorities can be set as required. 

 

Built-in loudspeaker to monitor the audio signal of two channels. 

 

Automatic recording and temporary recording. 

 

Full system supervision, including main power supply, backup power 
supply, CPU, PTT microphone, power amplifier, speaker lines, dry 
contact inputs, network communication, etc. 

 

10 dry contact inputs with supervision and 8 dry contact outputs. 

Summary of Contents for RK-MCU

Page 1: ...M_2000060504_EN_1 0 INTEVIO Master Control Unit Product Instructions Model RK MCU M_2000061159_UL_1 1 ...

Page 2: ......

Page 3: ...r to extend power supply line Do not block the equipment s ventilation opening or put other equipment on it Safety guideline Protect this equipment against rainwater or moisture so as to avoid fire or electric shock Unpacking After removing the amplifier from the carton inspect for any exterior damage to the unit If damage is noted notify the carrier at once so that a claim can be justified Save a...

Page 4: ...ar water Clean only with a dry cloth Do not block any ventilation openings Install in accordance with the manufacturer s instructions Do not install on or near any heat sources such as radiators heat registers stoves or other apparatus including amplifiers that produce heat Do not defeat the safety purpose of the polarized or grounding type plug A polarized plug has two blades with one wider than ...

Page 5: ...ses shall be placed on the apparatus WARNING To reduce the risk of fire or electric shock do not expose this apparatus to rain or moisture The mains plug is used as disconnecting device and shall remain readily operable The apparatus is unsuitable for use in air handling spaces This device complies with part 15 of the FCC Rules Operation is subject to the following two conditions 1 This device may...

Page 6: ...4 Password Precaution Please change the password during the system deployment Users need to change the password regularly The password with six numbers is preferred ...

Page 7: ...ode Maximum 8 loudspeaker zones can be connected with a maximum power rating of 500W for each zone Built in 500W Class D power amplifier Supports external power amplifiers Flexible power amplifier redundancy One spare amplifier can back up all amplifiers in the system Built in 1GB Flash memory and 8GB SD card which can be used to store audio files recording files configuration data and log files e...

Page 8: ...lt in standard configuration allows to be used directly after installation Equipment configuration can be set or modified via configuration software Function Introduction Main backup power supply Zone control Amplifier redundancy Audio input allocation Digital volume control Automatic temporary recording Monitor function System supervision Live broadcast Business broadcast Background music broadca...

Page 9: ...ht The microphone socket is used to connect PTT microphone to MCU The indicator light is off in standby mode When microphone is active the light turns green When a fault is found the light turns orange 4 Device status indicator lights To indicate status of device power general fault CPU fault ground fault disabled status etc 5 VU meter To indicate the signal level of internal power amplifier 6 LCD...

Page 10: ...tons with status indicator lights which can be configured as needed 11 Audio source button status indicator light 8 audio source selection buttons and status indicator lights which can be configured as needed Rear Panel No Parts Ports Description 1 Audio output of CH1 Output signal of channel 1 It can be connect to external power amplifier or third party devices 2 Audio output of CH2 Output signal...

Page 11: ... 7 Power amplifier interface External power amplifier connection for two audio channels MCU will transmit audio signal and self test signal to power amplifier and receive the fault status from power amplifier 8 Spare power amplifier interface Spare power amplifier connection MCU will transmit audio signal and self test signal to power amplifier and receive the fault status from power amplifier 9 C...

Page 12: ...o transmit voice alarm status to third party system FAULT This is a dry contact output to transmit the general fault status to third party system FIRE It is unavailable CTRL This is reserved to connect to the third party system DEBUG 1 DEBUG 2 They will be used to upgrade the firmware 15 Loudspeaker interface Speaker line interface of 8 zones each zone has two speaker lines A B which are in parall...

Page 13: ...witch to set the work mode of current device and system 21 Calibration key To calibrate speaker line impedance 22 DC power output 24V DC power output 23 System extension interface Zone expander connection 24 Fan Cooling fan controlled by temperature 25 Backup power input 24 VDC backup power supply connection Note This function is not applied in North America 26 Grounding screw Grounding wire conne...

Page 14: ...BV Frequency response 100Hz 14KHz 3dB SNR 50dB A weighted Auxiliary input Number 2 Input sensitivity 1V 0dBV Input impedance 10 KΩ Frequency response 85Hz 18KHz 3dB SNR 80dB A weighted MIC LINE Input Input sensitivity 5mV 1V set by DIP switch Input impedance 20 KΩ Frequency response 80Hz 18KHz 3dB SNR 80dB A weighted Phantom power output 24V DC set by DIP switch Audio Output Output channels CH1 CH...

Page 15: ...tput signal 1 4V THD 0 1 Control signal Self testing amplifier fault and power saving control signal Loudspeaker Interface Zone Number 8 each has A and B output Max load power 500W Contact Input Output Contact input 10 contact input interfaces with supervision Contact output 8 contact output interfaces NO NC and COM Fault output and Alarm output Maximum voltage of the outputs AC 250V DC 30V Maximu...

Page 16: ... 1GB Flash Memory 8GB SD card Working Conditions Relative Humidity 95 without condensing Operating temperature 10 C 45 C 14 F to 113 F Storage temperature 40 C 70 C 40 F to 158 F Specification Dimension W H D 18 98 5 26 16 54 inches Packing dimension W H D 22 83 10 98 21 73 inches Net weight 24 25 lbs Gross weight 31 08 lbs ...

Page 17: ...5 6P 4 5 System interface terminals 3 81 8P 2 6 Loudspeaker terminals 5 08 16P 2 7 Power amplifier terminals 5 08 2P 6 8 DC Power output terminal 5 08 2P 1 9 Backup power terminal 7 62 4P 1 10 Twisted pair cable 2m 1 11 Audio cable 1 12 AC power cable 1 13 Fuses 10A 1 14 Product Instructions 1 15 PTT Microphone 1 16 Machine Legs 4 ...

Page 18: ...e Road Northford CT 06472 USA Tel 1 800 323 4576 Manufacturer Life Safety A V Guangzhou Co LTD No 257 Junye Road Guangzhou GETDD East 510530 China Tel 86 0 20 2839 9600 Fax 86 0 20 2820 8706 2017 Honeywell International Inc All rights reserved ...

Reviews: