If a labeled wire does not match any terminal
designation, see diagram below.

Do not use C, X or B. Wrap bare end of wire
with electrical tape.

If wires are connected to both Rh and Rc
terminals, remove jumper (see previous
page).

s

Connect Wires (less common wiring)

400-147-042-A (69-2336ES-01 RCT8100 TH147P Quick Installation Guide) ENG.fm  Page 7  Thursday, October 1, 2009  10:36 AM

Summary of Contents for RCT8100

Page 1: ...Quick Installation Guide RCT8100 Programmable Thermostat 400 147 042 A 69 2336ES 01 RCT8100 TH147P Quick Installation Guide ENG fm Page 1 Thursday October 1 2009 10 36 AM ...

Page 2: ...Do you need assistance We are here to help Call 1 800 468 1502 400 147 042 A 69 2336ES 01 RCT8100 TH147P Quick Installation Guide ENG fm Page 0 Thursday October 1 2009 10 36 AM ...

Page 3: ... following pages n Identify your system type o Remove your old thermostat p Identify the wires q Mount the new wallplate r Connect the wires s If the wire labels don t match t Specify the furnace type u Install the batteries v Install the thermostat w Set the system 400 147 042 A 69 2336ES 01 RCT8100 TH147P Quick Installation Guide ENG fm Page 1 Thursday October 1 2009 10 36 AM ...

Page 4: ...a millivolt system a central heating and cooling system If you are not sure of your system type or if you have any other questions call us toll free at 1 800 468 1502 n Identify System Type 1 This thermostat is not compatible with heat pumps or multi stage systems 400 147 042 A 69 2336ES 01 RCT8100 TH147P Quick Installation Guide ENG fm Page 2 Thursday October 1 2009 10 36 AM ...

Page 5: ...ICE Do not put your old thermostat in the trash if it contains mercury in a sealed tube Contact your local waste management authority for instructions regarding recycling and proper disposal o Remove Old Thermostat 2 Do not remove wallplate yet 400 147 042 A 69 2336ES 01 RCT8100 TH147P Quick Installation Guide ENG fm Page 3 Thursday October 1 2009 10 36 AM ...

Page 6: ...short other wires Disconnect wires and remove the old wallplate only after all wires are labeled Wrap the wires around a pencil to prevent them from falling though the wall opening p Identify Wires 3 Do not use non connected wires Do not use C or C1 wires Identify and label each wire IGNORE WIRE COLORS Use terminal screw designations to identify wires 400 147 042 A 69 2336ES 01 RCT8100 TH147P Quic...

Page 7: ...les or use existing holes Insert plastic anchors Pass wires through opening of wallplate and secure wallplate to the wall using provided screws q Mount New Wallplate 4 Labels don t match If a wire does not match any terminal on the thermostat see next page 400 147 042 A 69 2336ES 01 RCT8100 TH147P Quick Installation Guide ENG fm Page 5 Thursday October 1 2009 10 36 AM ...

Page 8: ...nal screws using a screwdriver insert the wires then tighten the screws 3 Push any excess wire back into the wall opening r Connect Wires typical wiring 5 Removejumper if you have both R and Rc wires 400 147 042 A 69 2336ES 01 RCT8100 TH147P Quick Installation Guide ENG fm Page 6 Thursday October 1 2009 10 36 AM ...

Page 9: ...am below Do not use C X or B Wrap bare end of wire with electrical tape If wires are connected to both Rh and Rc terminals remove jumper see previous page s Connect Wires less common wiring 400 147 042 A 69 2336ES 01 RCT8100 TH147P Quick Installation Guide ENG fm Page 7 Thursday October 1 2009 10 36 AM ...

Page 10: ... G terminal t Specify Furnace Type 6 HG Leave the jumper in this factory set position if you have a gas or oil furnace HE Place the jumper to this position if you have an electric furnace J2 jumper 400 147 042 A 69 2336ES 01 RCT8100 TH147P Quick Installation Guide ENG fm Page 8 Thursday October 1 2009 10 36 AM ...

Page 11: ...for approximately 5 seconds Afterwards the screen displays the actual tempera ture It is normal that the displayed temperature be higher than the ambient temperature if you are holding the thermostat The thermostat will display the ambient temperature once it is installed on the wall By default the setpoint is 70 F 21 C u Install Batteries 7 400 147 042 A 69 2336ES 01 RCT8100 TH147P Quick Installa...

Page 12: ... on the wallplate 2 Tighten the screw and install the coverplate 3 Turn power back on at the heating cooing system v Install thermostat 8 400 147 042 A 69 2336ES 01 RCT8100 TH147P Quick Installation Guide ENG fm Page 10 Thursday October 1 2009 10 36 AM ...

Page 13: ...es per hour 3 2 3 4 5 or 6 5 1 Default settings are shown in bold and underlined 2 See page 3 of Operating Manual 3 Use the system switch to switch between the two parameters 4 For optimal heating control use the setting that matches your sys tem as follows 2 30 min steam gravity 3 20 min hot water 90 high efficiency furnace 4 15 min gas or oil 5 12 min alternate setting for gas or oil 6 10 min el...

Page 14: ...85 Douglas Drive North Golden Valley MN 55422 Honeywell Limited 35 Dynamic Drive Scarborough Ontario M1V 4Z9 http DIYthermostats honeywell com Printed in USA 69 2336ES 01 10 09 400 147 042 A 69 2336ES 01 RCT8100 TH147P Quick Installation Guide ENG fm Page 12 Thursday October 1 2009 10 36 AM ...

Page 15: ...Guía de instalación rápida RCT8100 Termostato programable 400 147 042 A 69 2336ES 01 RCT8100 TH147P Quick Installation Guide SPA fm Page 1 Thursday October 1 2009 10 31 AM ...

Page 16: ... Necesita asistencia Estamos aquí para ayudarlo Llame al 1 800 468 1502 400 147 042 A 69 2336ES 01 RCT8100 TH147P Quick Installation Guide SPA fm Page 0 Thursday October 1 2009 10 31 AM ...

Page 17: ...n Identificar el tipo de sistema o Retirar el viejo termostato p Identificar los cables q Montar la nueva placa mural r Conectar los cables s Cuando los cables no coinciden t Especificar el tipo de estufa u Instalar las pilas v Instalar el termostato w Configurar el sistema 400 147 042 A 69 2336ES 01 RCT8100 TH147P Quick Installation Guide SPA fm Page 1 Thursday October 1 2009 10 31 AM ...

Page 18: ... de milivoltios Sistema de calefacción y aire acondicionado central Si no supiera cuál es su sistema o si tuviera otras preguntas llámenos sin cargo al 1 800 468 1502 n Identificar el tipo de sistema 1 Este termostato no es compatible con las bombas de calor o los sistemas multietapas 400 147 042 A 69 2336ES 01 RCT8100 TH147P Quick Installation Guide SPA fm Page 2 Thursday October 1 2009 10 31 AM ...

Page 19: ...CIA SOBRE EL MERCURIO no ponga su viejo termostato en la basura si contiene mercurio en un tubo sellado Comuníquese con la autoridad de gestión de desechos local para saber cómo reciclarlo o eliminarlo adecuadamente o Retirar el viejo termostato 2 No retirar la placa mural todavía 400 147 042 A 69 2336ES 01 RCT8100 TH147P Quick Installation Guide SPA fm Page 3 Thursday October 1 2009 10 31 AM ...

Page 20: ... los cables y retirar la vieja placa mural sólo después de haber identificado y etiquetado los cables Enroscarlos en un lápiz para impedirles caer dentro del agujero de la pared p Identificar los cables 3 No utilizar cables no conectados No utilizar cables C o C1 Identificar y etiquetar cada cable IGNORAR LOS COLORES DE LOS CABLES usar las designaciones de los tornillos terminales para identificar...

Page 21: ...xistentes Introducir los anclajes plásticos Pasar los cables por la apertura de la placa mural y asegurar la placa a la pared con los tornillos provistos q Instalar la nueva placa mural 4 Las etiquetas no coinciden Si un cable no corresponde a ningún terminal del termostato referirse a la página siguiente 400 147 042 A 69 2336ES 01 RCT8100 TH147P Quick Installation Guide SPA fm Page 5 Thursday Oct...

Page 22: ...cables del terminal con un destornillador luego ajustar los tornillos 3 Empujar el exceso de cables en el agujero de la pared r Conectar los cables conexión típica 5 Retirar el puente si hay cables R y Rc 400 147 042 A 69 2336ES 01 RCT8100 TH147P Quick Installation Guide SPA fm Page 6 Thursday October 1 2009 10 31 AM ...

Page 23: ... siguiente No usar C X o B Enroscar el extremo desnudo con cinta aisladora Si los cables están conectados con los terminales Rh y Rc retirar el puente ver la página previa s Conectar los cables conexión menos común 400 147 042 A 69 2336ES 01 RCT8100 TH147P Quick Installation Guide SPA fm Page 7 Thursday October 1 2009 10 31 AM ...

Page 24: ...minal G t Especificar el tipo de estufa 6 HG Dejar el puente en esta posición en el caso de un sistema de calefacción a gas o a aceite HE Colocar el puente en esta posición en el caso de un sistema de calefacción eléc trico Puente J2 400 147 042 A 69 2336ES 01 RCT8100 TH147P Quick Installation Guide SPA fm Page 8 Thursday October 1 2009 10 31 AM ...

Page 25: ...edor de 5 segundos Una vez terminadas las pruebas la pantalla indicará la temperatura actual Es normal que la temperatura indicada sea más elevada que la temperatura ambiente si se tiene el termostato en la mano El ter mostato indicará la temperatura ambiente cuando esté instalado en la pared El punto de ajuste de fábrica es de 70 F 21 C u Instalar las pilas 7 400 147 042 A 69 2336ES 01 RCT8100 TH...

Page 26: ... 2 Ajustar los tornillos e instalar la placa de cubierta 3 Conectar el sistema de calefacción aire acondicionado a la electricidad v Instalar el termostato 8 400 147 042 A 69 2336ES 01 RCT8100 TH147P Quick Installation Guide SPA fm Page 10 Thursday October 1 2009 10 31 AM ...

Page 27: ...hora 3 2 3 4 5 ó 6 5 1 Lo valores de fábrica están en negrita y subrayados 2 Ver la página 3 del Manual de Uso 3 Usar el conmutador del sistema para cambiar entre los dos parámetros 4 Para un control óptimo de la calefacción utilizar la configuración correspondiente al sistema de la siguiente manera 2 30 min vapor gravedad 3 20 min agua caliente 90 calefactor de alta eficacia 4 15 min gas o aceite...

Page 28: ...c 1985 Douglas Drive North Golden Valley MN 55422 Honeywell Limited 35 Dynamic Drive Scarborough Ontario M1V 4Z9 http DIYthermostats honeywell com Impreso en EE UU 69 2336ES 01 10 09 400 147 042 A 69 2336ES 01 RCT8100 TH147P Quick Installation Guide SPA fm Page 12 Thursday October 1 2009 10 31 AM ...