This wireless outdoor alarm device provides audible and visual notifications 

and is intended for use with Honeywell Home controls that support PROSiX™ 

series devices.

 

 

PROSiXSIRENO

 

 

POWER UP 

 

MOUNTING 

The PROSiXSIRENO can be mounted on the wall or on the 

ceiling. 
The rear tamper breakout MUST be mounted to a stud, solid 

wood, or with a robust wall anchor. 
After enrolling, verify adequate signal strength by conducting a sensor 

test (see controller’s instructions) with the device in its intended 

mounting location. Adjust the device location and orientation as 

necessary.

 

 

ENROLL

 

1.  Set the controller in Programming Mode. Follow the controller’s instructions to begin enrollment. 
2.  Insert four 1.5V AA Lithium batteries (included) to activate the device and begin the enrollment process. 
3.  The Green LED flashes rapidly during enrollment (up to about 20 seconds*) The device sends its unique MAC ID address 

(Serial Number) and Services information to the controller. 

NOTE

: Enrollment time varies depending on the signal strength between the device and the controller.  

4.  Enrollment is confirmed when the Green LED is ON for 3 seconds.  
5.  The device did not enroll in the system if: 

  The sensor chirps and the device powers down.

 

  The Green LED flashes rapidly when the device is removed from the mounting bracket (the tamper switch is triggered).

 

To restart the enrollment process, ensure the system is in programming mode and activate the tamper switch. 

NOTE

: Once enrolled in a system, the device cannot be used with another controller until it is removed from the current 

controller.  See the Controller’s instructions for details. 

 

DEFAULT PROSIXSIRENO 

If the device is enrolled in a panel 

different than the intended panel, and 

you are unable to delete it from the 

unintended panel, default the device: 

1.  Open the cover and remove the 

batteries. 

2.  Hold down the tamper switch 

while reinserting the batteries. 

3. 

LED blinks rapidly upon 

successful deletion.

 

 

This procedure is available for 24 hours after enrollment with a panel and the device 

remains powered (battery installed). 

Summary of Contents for PROSiXSIRENO

Page 1: ... MAC ID address Serial Number and Services information to the controller NOTE Enrollment time varies depending on the signal strength between the device and the controller 4 Enrollment is confirmed when the Green LED is ON for 3 seconds 5 The device did not enroll in the system if The sensor chirps and the device powers down The Green LED flashes rapidly when the device is removed from the mountin...

Page 2: ... second then OFF for 1 second 3 After 7 days the sounder chirps once every 45 seconds until the batteries are replaced or die See the Battery Replacement section TEST THE PROSIXSIRENO The PROSiXSIRENO should be tested immediately after installation and weekly Activate Test Mode remotely from the Controller see Controller s manual for details The product must be tested at least once a year Test Mod...

Page 3: ...ccordance with the manufacturer s instructions may cause interference to radio and television reception It has been type tested and found to comply with the limits for a Class B computing device in accordance with the specifications in Part 15 of FCC Rules which are designed to provide reasonable protection against such interference in a residential installation However there is no guarantee that ...

Page 4: ...alth Any attempt to reverse engineer this device by decoding proprietary protocols de compiling firmware or any similar actions is strictly prohibited SUPPORT WARRANTY INFORMATION For the latest documentation and support please go to www resideo com For the latest warranty information please go to www security honeywellhome com warranty The Honeywell Home Trademark is used under license from Honey...

Reviews: