PRO TH4210D Programmable Thermostat
7
6
5
To begin, press and hold the and
buttons until the display changes
Function
number
Press
to change settings
Press
to advance to next function
Press and hold
to exit and save settings
Setting
Installer setup
Follow the procedure below to configure the thermostat to match the installed
heating/cooling system, and customize feature operation as desired.
Setup
Installer system test
After completing the installer setup above, press the
button again to begin a
system test (see next page).
Press and hold both buttons
Setup Function
Settings & Options
5 For gas or oil furnaces of less than 90% efficiency
1
For steam or gravity systems
3
For hot water systems & furnaces of over 90% efficiency
9
For electric furnaces
[Other cycle rate options: 2, 4, 6, 7, 8, 10, 11 or 12 CPH]
9 For electric emergency heat
1
For steam or gravity systems
3
For hot water systems & furnaces of over 90% efficiency
5
For gas or oil furnaces of less than 90% efficiency
[Other cycle rate options: 2, 4, 6, 7, 8, 10, 11 or 12 CPH]
3 Recommended for most compressors
[Other cycle rate options: 1, 2, 4, 5 or 6 CPH]
1 On
**See page 9
0
Off
0 Fahrenheit
1
Celsius
5 Five-minute compressor off time
**See page 9
[Other options: 0, 1, 2, 3 or 4-minute off time]
Auxiliary heat
cycle rate
(CPH: cycles/hour)
Emergency heat
cycle rate
(CPH)
Compressor
cycle rate
(CPH)
Adaptive Intelligent
Recovery
Temperature
display
Compressor
protection
6
8
9
13
14
15
Summary of Contents for PRO TH4210D
Page 1: ...Installation Guide TH4210D Programmable Thermostat ...