background image

Summary of Contents for PRO TH4110B

Page 1: ......

Page 2: ...ce _ CAUTION EQUIPMENT DAMAGE HAZARD To prevent possible compressor damage do not operate cooling system when outdoor temperature is below 50 F 1O C Read and save these instructions U S Registered Trademark Patents pending Copyright 2005 Honeywell Internationalinc All rights reserved ...

Page 3: ...and day 6 System switch Heat Cool 7 Fan switch Auto On 8 Using program schedules 9 Program schedule overrides 12 Compressor protection 14 Appendices Batte W replacement 15 In case of difficulty 16 Customer assistance 18 Accessories 18 Limited warrant3_ 19 _ HAZARD CAUTION EQUIPMENT DAMAGETo prevent possible compressor damage do not operate cooling system when outdoor temperature is below 50 F 10 C...

Page 4: ...asy to use push button climate control Festu res Separately programmable weekday weekend schedules One touch temp control overrides program schedule at any time EnergyStar _ compliant to greatly reduce your heating cooling expenses Large clear display is easy to read Displays both roonl temperature and temperature setting Built in compressor protection ...

Page 5: ... 2 Select system setting Heat Cool Preset to Heat To change see page 7 3 Select fan setting Auto On Preset to Auto To change see page 8 4 Program schedules Preset to energy saving levels while you re at work or asleep assumes you wake at 6 am leave at 8 am return at 6 pm and go to bed at 10 pro To change see pages 9 11 ONE TOUCH TEMP CONTROL You can override the program schedule at any time and ma...

Page 6: ...ride _ programmed temperature control Run Press to resume program schedule Fan switch see page 8 On Fan runs continuously Auto Fan runs only when heating or cooling system is on System switch see page 7 Cool Thermostat controls only the cooling system Heat Thermostat controls only the heating system Off Heating and cooling systems are off ...

Page 7: ...ostat m Low battery warning Current day time see page 6 see page 15 Current inside Temperature setting temperature see pages 11 13 Current program period Wake Leave Return Sleep see pages 10 11 Heat On Cool On If flashing see page 14 ...

Page 8: ...t the clock time 2 Press the SETbutton then press A or Y to select the day of the week 3 Press RtlR to save exit Press SET then select current day Note If the display flashes Set Clock the thermostat will follow your settings for the weekday Wake time period until you reset the time and day ...

Page 9: ...eat Thermostat controls only the heating system Cool Thermostat controls only the cooling system Off Heating and cooling systems are off Set SYSTEM switch to control the heating or cooling system CAUTION EQUIPMENT DAMAGE HAZARD To prevent possible compressor damage do not operate cooling system when outdoor temperature is below 50 F 10 C ...

Page 10: ...se whether the fan runs continuously or only as needed In uto mode the most commonly used setting the fan runs only when the heating or cooling system is on If set to On the fan runs continuously Use this setting for improved air circulation or br more efficient air cleaning ...

Page 11: ...00 pm 7 lo ILl SLEEP 1O 00 pm _ io OG Set to the time you awaken and the temperature you want during the morning until you leave lk r the day Set to the time you leave home and the temperature you want while you are away usually an energy saving level Set to the time you return home and the temperature you want during the evening until bedtime Set to the time you go to bed and the temperature you ...

Page 12: ...e your heating cooling expenses by as much as 33 See next page to adjust times and temperatures of each time period WaRe 6 00 am Leave 8 00 am Return 6 00 pm SBeep 10 00 pm Heat Men Fr0 _l ao ILl im _o oc _l ao ILl oc Cool Mon Fri Heat Sat Sun Cool Sat Sun _l O _l a o 71 o i _ ill i Zo j I i o OD Tt o _l I I _o _l lo IO OtZ IO 10 ...

Page 13: ...et the temperature for this time period then press SET 4 Set time and temperature for the next time period Leave Repeat steps 2 and 3 tbr each weekday time period 5 Press SET to set weekend time periods Sat Sun then press RUN to save exit Note Make sure the thermostat is set to the system you want to program Heat or Cool Note To cancel an unwanted time period except Wake press and hold A HOLDfor 4...

Page 14: ... temperature will be maintained only until tile next programmed time period Press to resume program schedule begins see page 10 For example if you want to mrn up the heat early in the morn ing it will automatically be lowered later when you leave R r the day To cancel the temporary setting at an time press RUN Note Make sure the thermostat is set to the system you want to control heat or cool 12 ...

Page 15: ...riods The Hold feature turns off the program schedule and allows you to adjust the thermostat manually as needed Press to resume program schedule Whatever temperature you set will be maintained 24 hours a day until you manually change it or press RtlRto cancel Hold and resume the progranl schedule Note Make sure the thermostat is set to the system you want to control heat or cool 13 ...

Page 16: ...tarted too soon after shutdown This feature R rces the compressor to wait R ra few minutes befbre restarting During the wait time the message Cool On Message flashes until safe or Heat On if you have a heat pump will restart time has elapsed flash on the display When the safe wait time has elapsed the message stops flashing and the compressor turns on 14 ...

Page 17: ...batteries are depleted Even it the warllJng does not appear you should replace batteries once a ear or beR re leavh_g home R rmore than a month Turn thermostat over insert fresh AA alkaline batteries then reinstall thermostat If batteries are fl_serted withfl_ 1 mflmte the tfl_ ie and day will not have to be re_t All other setth_gs are permanently stored h_memory and do not require batte W power 1...

Page 18: ...Heating or cooling system does net respond e Set system switch to Heat see page 7 Make sure the temperature is set higher than the inside temperature Set system switch to Cool see page 7 Make sure the temperature is set lower than the Inside temperature Check circuit breaker and reset if necessary Make sure power switch at heating cooling system is on Make sure furnace door is closed securely Wait...

Page 19: ...o restart safely without damage to the compressor see page 14 o Set the System switch to Heat and set the temperature level above the current room temperature see page 7 Cool On is Set the System switch to Cool and set the temperature level below the not displayed current room temperature see page 7 TO restore Energy Star _ default settings Follow these steps to restore Energy Star default setting...

Page 20: ...er Care tolMYee at 1 800 468 1502 Turn thermostat over to find model number and date code To save time please note your model number and date code beR re calling Accessories For accessories please call Honeywell Customer Care toll free at 1 800468 1502 Cover plate Part No 50002883 001 Used to cover marks left by old thermostats 18 ...

Page 21: ... defective or malflmctions Honeywell shall repair or replace it at Honeywell s option f the product is defective i return it with a bill of sale or other dated proof of purchase to the place from which you purchased it or ii call Honeywell Customer Care at 1 800 468 1502 Customer Care will make the determination whether the product should be returned to the lk_llowing address Honeywell Return Good...

Page 22: ...oneywell s sole responsi ilit3 shall be to repair or replace the product within the terms stated above HONEYWELL SHALL NOT BE LIABLEFOR ANY LOSS OR DAMAGE OF ANY KIND INCLUDING ANY INCIDENTAL OR CONSEQUENTIAL DAMA ES RESULTING DIRECTIX OR INDIRECTIX FROM ANY BREACH OF ANY WARRANTY EXPRESS OR MPLIED OR ANY OTHER FAILUREOF THIS PRODUCT Some states do not allow the exclusion or limitation of incident...

Page 23: ... states do not allow limitations on how long an implied warranty lasts so the above limitation may not apply to you This warren D gives you specific legal rights and you may have other rights which vary from state to state ifyou have aW questions concerning this warranty please write Honeywell Customer Relations 1985 Douglas Dr Golden ValleB MN 55422 or call 1 800 468 1502 in Canada write Retail P...

Page 24: ......

Reviews: