Honeywell PEHA 960/3 PSB/D Installation And Operating Instruction Download Page 4

D - 2

126249-04

PEHA_M_960-3_ PSB-D (Rev05_130320)

GB - 2

PEHA Elektro GmbH & Co. KG

Postfach 1727 • D-58467 Lüdenscheid • Tel.: (02351)185-0 • Fax: (02351)27666 • e-mail: peha@peha.de • Internet: www.peha.de

 

cOnnecTIOn DIAgrAM

Art. Nr.: 940/24 EM RÜ DIAG

16A / 250V~

Adress switch

Address switch

3

3

INPUT
max. 16A / 250V~

OUTPUT
max. 16A / 250V~

INPUT 8-11

8

9

10

11

B A

+24V

BUS - IN

A B

+24V

BUS - OUT

A B

+24V

BUS - OUT

INPUT 12-15

12

13

14

15

INPUT

250V~

L

N

3

16A / 250V~

ID:

µ

µ

out

0

N

L

out

1

N

L

O

UT

PU

T

25

0V

~

N

L

µ

out

3

N

L

µ

out

2

N

L

_

+

Dim

1..10V

_

+

Dim

1..10V

_

+

Dim

1..10V

_

+

Dim

1..10V

2AX

Max. output per chanel 250V~

System-Box

Art.-Nr.: 960/3 PSB/D

1 2 3 4 5

7 8

6

out

0

L

N

out

1

L

N

out

2

L

N

µ

µ

µ

16A / 250V~

Address switch

3

out

4

N

L

out

3

N

L

O

UT

PU

T

25

0V

~

N

L

out

5

N

L

µ

µ

µ

3

INPUT

250V~

L

N

3

INPUT
max. 16A / 250V~

OUTPUT
max. 16A / 250V~

INPUT 8-11

8

9

10

11

B A

+24V

BUS - IN

A B

+24V

BUS - OUT

A B

+24V

BUS - OUT

INPUT 12-15

12

13

14

15

ID:

M

2300W

600VA

1250W

2AX

Max. output per chanel 250V~

Art.-Nr.: 960/3 PSB

System-Box

1 2 3 4 5

7 8

6

Art. Nr.: 940/24 EM RÜ DIAG

16A / 250V~

Adress switch

Address switch

3

3

INPUT
max. 16A / 250V~

OUTPUT
max. 16A / 250V~

INPUT 8-11

8

9

10

11

B A

+24V

BUS - IN

A B

+24V

BUS - OUT

A B

+24V

BUS - OUT

INPUT 12-15

12

13

14

15

INPUT

250V~

L

N

3

16A / 250V~

ID:

µ

µ

out

0

N

L

out

1

N

L

O

UT

PU

T

25

0V

~

N

L

µ

out

3

N

L

µ

out

2

N

L

_

+

Dim

1..10V

_

+

Dim

1..10V

_

+

Dim

1..10V

_

+

Dim

1..10V

2AX

Max. output per chanel 250V~

System-Box

Art.-Nr.: 960/3 PSB/D

1 2 3 4 5

7 8

6

Art. Nr.: 940/24 EM RÜ DIAG

16A / 250V~

Adress switch

Address switch

3

3

INPUT
max. 16A / 250V~

OUTPUT
max. 16A / 250V~

INPUT 8-11

8

9

10

11

B A

+24V

BUS - IN

A B

+24V

BUS - OUT

A B

+24V

BUS - OUT

INPUT 12-15

12

13

14

15

INPUT

250V~

L

N

3

16A / 250V~

ID:

µ

µ

out

0

N

L

out

1

N

L

O

UT

PU

T

25

0V

~

N

L

µ

out

3

N

L

µ

out

2

N

L

_

+

Dim

1..10V

_

+

Dim

1..10V

_

+

Dim

1..10V

_

+

Dim

1..10V

2AX

Max. output per chanel 250V~

System-Box

Art.-Nr.: 960/3 PSB/D

1 2 3 4 5

7 8

6

code switch (modul adress)

1

2

4

4

5

6

6

connector assignment of the Phc dimming box

e. g. push button

at input 8

┴ B A 24

24 A B ┴

24 A B ┴

3

3

3

3

Push down the clamping device by 

using a screwdriver!

+

n

L

caution! 

When  connecting  the  electronic 

ballasts, do not change places of 

allocation of power supplies (L, N, 

PE) and bus line (+, –)!

caution!!

–  Only use approved „Wieland“ connectors! Plug the connector into the provided connection until you hear them engage into place!

 

The connectors can be reordered from 

  PEHA or WIELAND (www.wieland.de).
–  The maximum load of the PHC system box (max. 4000 W / 250 VAC /16A) must be observed when connecting consumers!
–  The inputs for push buttons are connected to the supply voltage of the PEHA PHC system. Care must be taken to ensure that no connection is made to alternating 

  current circuits (230 VAC). Such a connection can damage the PHC system!
–  During connection, care must be taken to ensure that the connector assignment of the data cable is not interchanged.
–  In order to guarantee the full range of functions of the PHC system box, the 230 VAC power supply must be connected!

1

InPuT 250V~

Input for Power supply 230 VAC /16 A (L, N, PE)

GST 18i3 F B2 Z charcoal 92.933.0153.0

2

OuTPuT 250V~

Output for power supply 230 VAC /16A of further PHC system boxes

GST 18i3 F S2 Z charcoal 92.934.0153.0

3

OuT 0-3

utput (max. 230 VAC /16 A) for connecting dimmable electronic ballasts (1-10V).

caution!

 The maximum load of the PHC system box must be observed!

GST 18i5 S S1 Z pale blue 92.954.3453.0

4

InPuT 8-15

Input for push button, switch (max. 3 switches per PHC system boxes)

Type 8213 BFK 8 pole 25.820.3853.0

5

Bus-In

PHC bus input for PHC bus

Type 8213 BFK 4 pole 25.840.3453.0

6

Bus-OuT

PHC bus output for further PHC module

Type 8213 SUFK 4 pole 25.857.3453.0

WIeLAnD

gesis range

wiecon range

Summary of Contents for PEHA 960/3 PSB/D

Page 1: ...s Versorgungs netz ist die elektrische Anlage spannungsfrei zu schalten Es sind die geltenden Gesetze und Normen des Landes einzuhalten in dem das Gerät betrieben wird Die PHC Dimmbox kann dezentral mit den mitgelieferten Schrauben und Dübeln montiert werden z B auf eine ebene Wand oder in eine Zwischendecke Das Unterteil der PHC Dimmbox wird als Schablone für die Bohrlöcher benutzt Installation v...

Page 2: ...1 10V _ Dim 1 10V 2AX Max output per chanel 250V System Box Art Nr 960 3 PSB D 1 2 3 4 5 7 8 6 Kodierschalter Moduladresse 1 2 4 4 5 6 6 Anschlussbild PHC Dimmbox z B Anschluss von Taster an Input 8 24 A B 24 A B 3 3 3 3 Klemmvorrichtung mit Schraubendreher herunterdrücken B A 24 N L Achtung Beim Anschluss der EVGs nicht die Anschlussbelegung der Ver sorgungsleitung L N PE und Datenleitung vertaus...

Page 3: ... for further PHC system boxes or PHC modules is carried out at the BUS OUT output Notes Switch off power supply before connecting or disconnecting bus line The module can be positioned anywhere in the data line The module is supplied with voltage by the bus line Coding switch The coding switch sets the module address The setting is presented in the PHC software under menu item Components Modules N...

Page 4: ...V _ Dim 1 10V _ Dim 1 10V _ Dim 1 10V 2AX Max output per chanel 250V System Box Art Nr 960 3 PSB D 1 2 3 4 5 7 8 6 Code switch modul adress 1 2 4 4 5 6 6 Connector assignment of the PHC dimming box e g push button at input 8 B A 24 24 A B 24 A B 3 3 3 3 Push down the clamping device by using a screwdriver N L Caution When connecting the electronic ballasts do not change places of allocation of pow...

Page 5: ...De aansluiting van de dataleiding gebeurt met een bijgeleverde 4 polige verbindingsstekker Opmerking Vóór het loskoppelen van de busleiding dient de spanningsverzorging te worden uitgeschakeld De positie van de module in de dataleiding is willekeurig Via de busleiding wordt de module van spanning voorzien Codeerschakelaar Met de codeerschakelaar wordt het moduleadres ingesteld De instelling is in ...

Page 6: ...0 3 PSB D 1 2 3 4 5 7 8 6 Codeerschakelaar moduleadres 1 2 4 4 5 6 6 Aansluiting van de PHC dimbox bijv toets T1 op de Input 8 B A 24 24 A B 24 A B 3 3 3 3 Druk de kleminrichting met een schroevendraaier naar beneden N L LET OP Bij de aansluiting van de evsa s mogen de contacten van de voedingsleiding L N PE en dataleiding niet worden verwisseld Let Op De bijgeleverde stekkers van Wieland dienen t...

Reviews: