Honeywell Notifier High-Speed NOTI-FIRE-NET Instruction Manual Download Page 17

Manufacturer Warranties and Limitation of Liability

Manufacturer Warranties.

  Subject to the limitations set forth herein, Manufacturer

warrants that the Products manufactured by it in its Northford, Connecticut facility
and sold by it to its authorized Distributors shall be free, under normal use and
service, from defects in material and workmanship for a period of thirty six months
(36) months from the date of manufacture (effective Jan. 1, 2009).  The Products
manufactured and sold by Manufacturer are date stamped at the time of production.
Manufacturer does not warrant Products that are not manufactured by it in its
Northford, Connecticut facility but assigns to its Distributor, to the extent possible,
any warranty offered by the manufacturer of such product.  This warranty shall be
void if a Product is altered, serviced or repaired by anyone other than Manufacturer
or its authorized Distributors.  This warranty shall also be void if there is a failure to
maintain the Products and the systems in which they operate in proper working
conditions.

MANUFACTURER MAKES NO FURTHER WARRANTIES, AND DISCLAIMS ANY
AND ALL OTHER WARRANTIES, EITHER EXPRESSED OR IMPLIED, WITH
RESPECT TO THE PRODUCTS, TRADEMARKS, PROGRAMS AND SERVICES
RENDERED BY MANUFACTURER INCLUDING WITHOUT LIMITATION,
INFRINGEMENT, TITLE, MERCHANTABILITY, OR   FITNESS FOR ANY
PARTICULAR PURPOSE.  MANUFACTURER SHALL NOT BE LIABLE FOR ANY
PERSONAL INJURY OR DEATH WHICH MAY ARISE IN THE COURSE OF, OR AS
A RESULT OF, PERSONAL, COMMERCIAL OR INDUSTRIAL USES OF ITS
PRODUCTS.

This document constitutes the only warranty made by Manufacturer with respect to
its products and replaces all previous warranties and is the only warranty made by
Manufacturer.  No increase or alteration, written or verbal, of the obligation of this
warranty is authorized.  Manufacturer does not represent that its products will
prevent any loss by fire or otherwise.

Warranty Claims.

  Manufacturer shall replace or repair, at Manufacturer's discretion,

each part returned by its authorized Distributor and acknowledged by Manufacturer
to be defective, provided that such part shall have been returned to Manufacturer
with all charges prepaid and the authorized Distributor has completed Manufacturer's
Return Material Authorization form.  The replacement part shall come from
Manufacturer's stock and may be new or refurbished. THE FOREGOING IS
DISTRIBUTOR'S SOLE AND EXCLUSIVE REMEDY IN THE EVENT OF A
WARRANTY CLAIM. 

Warn-HL-08-2009.fm

High-Speed NFN Manual —

 P/N 54013:C4  8/8/2019

17

Summary of Contents for Notifier High-Speed NOTI-FIRE-NET

Page 1: ...Network System Interface High Speed NOTI FIRE NET Instruction Manual Document 54013 Rev C4 8 8 2019 ECN 18 0305 ...

Page 2: ...vide adequate warning of a fire Smoke detectors cannot be expected to provide adequate warning of fires caused by arson children playing with matches especially in bedrooms smoking in bed and violent explosions caused by escaping gas improper storage of flammable materials etc Heat detectors do not sense particles of combustion and alarm only when heat on their sensors increases at a predetermined...

Page 3: ...e sides or rear Before making modifications verify that they will not interfere with battery transformer or printed circuit board location Do not tighten screw terminals more than 9 in lbs Over tighten ing may damage threads resulting in reduced terminal contact pressure and difficulty with screw terminal removal This system contains static sensitive components Always ground yourself with a proper...

Page 4: ...te version for a specific application Documentation Feedback Your feedback helps us keep our documentation up to date and accurate If you have any comments or suggestions about our online Help or printed manuals you can email us Please include the following information Product name and version number if applicable Printed manual or online Help Topic Title for online Help Page number for printed ma...

Page 5: ...ts 7 2 2 Network Node Features 7 2 3 Network Interface Boards 9 2 4 High Speed Network Communications Modules in Repeater Mode 9 Section 3 Network Configurations 10 3 1 Point to Point Configuration 10 3 2 NFPA Class B Configurations 10 3 3 NFPA Class X Configurations 11 3 4 Network Wiring for Ground Fault Detection 12 Appendix A Compatibility with Other Systems 15 A 1 Honeywell Fire Systems 15 A 2...

Page 6: ...ith NFPA 72 and or the latest edition of UL 864 These applications will require the approval of the local Authority Having Jurisdiction AHJ NFS 3030 NFS 640 NCA 1 2 Related Documentation This table lists equipment that connects directly to High Speed Noti Fire Net For information about connecting non network devices to these network nodes refer to the installation manual s for your system To obtai...

Page 7: ...mming enables the DVC to react to events on other network nodes The minimum requirements for a DVC node are a DVC a High Speed Network Communications Module and a 24 VDC filtered power source This power can come from the control panel or from a regulated power limited remote power supply that is listed for Fire Protection Signaling use If local ground fault detection is required an AMPS 24 power s...

Page 8: ...ire Net network via the internet or intranet allowing the user to view the history event status device properties or other control panel informa tion The NWS 3 interfaces to the internet intranet using an IP based wire ethernet connection NFS 3030 NFS2 3030 With HS NCM W HS NCM MF HS NCM SF HS NCM WSF HS NCM WMF or HS NCM MFSF The NFS 3030 or NFS2 3030 occupy a single node address on the network T...

Page 9: ...S NCM MF Two multi mode fiber optic cable ports HS NCM SF Two single mode fiber optic cable ports HS NCM WSF One twisted pair wire port one single mode fiber optic cable port HS NCM WMF One twisted pair wire port one multi mode fiber optic cable port HS NCM MFSF One multi mode fiber optic cable port one single mode fiber optic cable port 2 4 High Speed Network Communications Modules in Repeater Mo...

Page 10: ...Noti Fire Net is capable of communicating using an NFPA Class B SLC refer to Figure 3 1 Under this class of operation a single open wire to wire short wire to wire short and open wire to wire short and ground or open and ground results in fragmenta tion of the network A single ground does not affect communication but is detected Each fragment of the network re configures to per mit communication a...

Page 11: ...ntioned circumstances while the system displays a trouble condition A single ground does not affect communication but is detected Class X operation may also be achieved using fiber optic cable or mixed media wire and fiber A B A B A B A B These two nodes continue to communicate with each other but cannot communicate with the other two nodes These two nodes continue to communicate with each other b...

Page 12: ...NCM configured as a repeater is employed two ground fault detection schemes are possible within a point to point configura tion One or both nodes refer to Figure 3 5 and Figure 3 6 may provide ground fault detection depending on the number of repeaters and the setting of the repeater ground fault detect switch SW4 at each repeater refer to EXAMPLES 1 and 2 EXAMPLE 1 In this example the node on the...

Page 13: ...lt detection is required Figure 3 7 shows how the ground fault detection switches must be arranged in order to achieve this maximum configuration EXAMPLE 4 The HS NCM can be shared between two network nodes In this example the HS NCM is shared between two nodes with separate power supplies Ground Fault detection should only be enabled for one of the power supplies NFNPTP3Prv2 WMF Power Supply GF D...

Page 14: ...de refer to Figure 3 9 the Ground Fault switch SW4 on the shared HS NCM should be set to OFF The power supply Ground Fault detection for each is dependent on the requirements of their respective network nodes Network Node Network Node Network Node Power Supply GF Detect Dis abled Power Supply GF Detect Enabled Power Supply GF Detect Enabled NUP Port NUP Ports NUP Port GF Detect Enabled Figure 3 9 ...

Page 15: ...L 864 9th Edition Products A 2 Johnson Controls Fire Systems The following Johnson Controls products will function as nodes on the High Speed Noti Fire Net IFC2 3030 IFC2 640 IFC 320 IFC 3030 IFC 640 JNCA 2 JNCA JDVC EM IFI Workstation These products are compatible with the High Speed NCM as described in this manual A 3 Tyco Unimode Fire Systems The following Tyco Unimode products will function as...

Page 16: ...16 High Speed NFN Manual P N 54013 C4 8 8 2019 Notes ...

Page 17: ...OR IMPLIED WITH RESPECT TO THE PRODUCTS TRADEMARKS PROGRAMS AND SERVICES RENDERED BY MANUFACTURER INCLUDING WITHOUT LIMITATION INFRINGEMENT TITLE MERCHANTABILITY OR FITNESS FOR ANY PARTICULAR PURPOSE MANUFACTURER SHALL NOT BE LIABLE FOR ANY PERSONAL INJURY OR DEATH WHICH MAY ARISE IN THE COURSE OF OR AS A RESULT OF PERSONAL COMMERCIAL OR INDUSTRIAL USES OF ITS PRODUCTS This document constitutes th...

Page 18: ...NOTIFIER 12 Clintonville Road Northford CT 06472 1610 USA 203 484 7161 www notifier com ...

Reviews: