background image

1.2 For Your  Installation

5

If the product is to be installed in cold places such as in a freezer, the piping pipes must be sealed 

in silicone to prevent the ingress of fresh air into the housing. Otherwise, moist air from outside 

may permeate the internal housing, causing moisture or water vapor to condense inside the 

product due to temperature differences inside and outside the product.

1) Do not drop or apply excessive force on the product. It's a dynamic, Do not install near the location.

2) Do not install at high temperature (50

°

C or higher), low temperature (less than 10

°

C), or high 

humidity. Risk of fire or electric shock.

3)

If you are moving the already installed product to a location, you must first remove the power and 

then move it or reinstall it.

4) Disconnect the camera's commercial power and network cable on a thunderstorm. Failure to do so 

may result in a fire or damage to the product.

5) Do not install near heat sources such as direct sunlight or Radiate. May cause fire.

6) Install it in a well ventilated area.

7) Avoid the direction of extremely bright light such as direct sunlight. May damage image sensor 

I have it.

8) Do not install water in a leak or splash area. Do not place objects filled with liquid, such as potting 

on the product.

9) The main power plug must be kept intact at all times.

10) If used outdoors, the camera may be damp due to temperature differences between inside and 

outside the unit. For this reason, it is recommended to install the camera indoors. When used 
outdoors, use internal fans and heaters. Activate it.

11) Do not allow the LAN Ethernet cable to extend outside the building.

ENG

Before installation

The product installation must be performed in accordance with the applicable laws and regulations.

In case of lightning, proper protection must be installed to prevent damage to the network camera

due to voltage spikes.

All precautions for safety of network cameras should be observed.

If cleaning is required, you must shut down the network camera and power down the camera. 

Only a soft dry cloth will be used, abrasive cleaners will be prohibited.

Do not repair the product yourself. High voltages may flow when the cover is opened and closed,

causing electric shock. The repair must be referred to our trained professional service personnel.

Summary of Contents for NEXPTZ4520HD-NET

Page 1: ...NEXPTZ4520HD NET Explosion proof Security Camera INSTALLATION MANUAL KOR ...

Page 2: ...stallation 2 1 Connecting Network 9 2 2 Connecting Cable 10 2 3 Searching for IP 11 3 Web browser Viewer 3 1 Connecting Web 12 3 2 Configuration mode 13 3 2 1 Network Setup 13 3 2 2 PTZ 15 Appendix Appendix 1 Product Dimension 18 Appendix 2 Additional Accessories 19 Appendix 3 Guarantee 22 KOR 2 ...

Page 3: ...ock topersons This symbol is intended to alert the user to the presence of important operating and maintenance servicing instruction in the literature accompanying the appliance Caution To reduce the risk of fire or electric shock in dangerous areas be sure to turn off the power before opening the product Caution To reduce the risk of fire or electric shock in dangerous areas be sure to finish the...

Page 4: ...shall be reconfigured through the Camera function There is no need to be adjusted physically but sunshield bracket may not be functional at this case Figure1 Method of Installation 1 2 For Your Installation KOR 4 ENG WARNING Gross weight of this system is about 30kg Use caution when lifting and installing It is recommended you to wear proper non slip gloves be worn during installation ...

Page 5: ...direction of extremely bright light such as direct sunlight May damage image sensor I have it 8 Do not install water in a leak or splash area Do not place objects filled with liquid such as potting on the product 9 The main power plug must be kept intact at all times 10 If used outdoors the camera may be damp due to temperature differences between inside and outside the unit For this reason it is ...

Page 6: ...an amount of thread locking compound not supplied to the thread of the product and the thread of the bolts 3 Secure the product to the mounting surface with the adjusted wrench and four M8x15mm stainless steel bolts and lock washers Tighten the bolts to 250 350 kgf cm 24Nm 34Nm Note Figure2 shows the product being installed on a Pedestal mount which is an optional product not supplied and if there...

Page 7: ...hread locking compound not supplied to the thread of the product and the thread of thebolts 3 There are more options such as wall corner and pole mount bracket to install refer to the mount bracket part page 4 Make sure the seal fitting not supplied and the threaded hole of this system are free of the dirt and particles 5 Assemble Nipple supplied the threaded hole of this system seal fitting and f...

Page 8: ...X optical zoom scale it s easy to monitor distant objects The Highest level Ex Class Ex d IIC T6 IECEx CE FCC KC Corrosion resistant SUS 316 Construction IP67 Protection 360º Continuous Planning with max 20º 90º sec High Speed Pan Tilt speed up to max 100º sec H 265 H 264 with latest Codec Various Preset function Home Function 255 Preset positions w focus 1 Autoscan 8 Tour 5 Pattern Positioning Fu...

Page 9: ...necting Network Figure4 Base Schematic of Installation 1 Figure4 is recommended for the base Schematic of Installation 2 If you wish to consist of another method or other components you must proceed to do after conferring with a manufacture ...

Page 10: ...r LAN Washer Pump KOR 10 Option Product EXWJ400 10A Operation of the down direction button when connecting the washer pump Connector Use Notation Color 1 Power Input Power AC 110V 220V L1 N GND Brown Blue Yellow Green 2 LAN RJ45 3 Option Washer Pump washer Pump Washer Pump Pump Pump Red Green ...

Page 11: ...tion IP address 192 168 1 108 Subnet mask 255 255 255 0 Gateway 192 168 1 1 IPC accessing information ID admin Password 1234 Figure 6 IPC Tool program Figure 7 IPC Tool Install 1 Figure 8 IPC Tool Install 2 Figure 9 IPC Tool Install 3 Figure 10 IPC Tool Execution 2 3 Searching for IP 11 ENG ...

Page 12: ...KOR 12 3 Connecting Web 3 1 Connecting Web For product security you must change the initial password to access it Changing Passwords are not recorded internally it cannot be restored and must be kept ...

Page 13: ...licable assign a default gateway address to the camera Preferred DNS Server If applicable assign a primary DNS server to the camera Alternate DNS Server If applicable assign a secondary DNS server to the camera Enable ARP Ping You can set or modify the camera s IP address using its MAC address This must be done within 2 minutes of rebooting the camera To enable ARP Ping to set the IP address 1 Obt...

Page 14: ... query format is Main Stream rtsp username password ip port cam realmonitor channel 1 subtype 0 Sub Stream rtsp username password ip port cam realmonitor channel 1 subtype 1 Note If you are streaming video on a Blackberry device set the format to H 264B the resolution to CIF and disable audio HTTPS Select the check box to enable HTTP Secure HTTPS protocol When HTTPS is enabled you can log in to th...

Page 15: ...et Set tour name You can input a self defined tour name here Start Add Begin tour Click it to add a new tour Preset Duration Click Add button you can add a new preset to the tour The default preset value is 1 Double click tour No you can see a dropdown list for you to select It is to set the staying time of the tour at each preset point Save Refresh Click it to save current setup Refresh current i...

Page 16: ...panning PTZ Function PTZ Speed Description PTZ speed Here you can set camera PTZ speed The PTZ speed is fixed during Preset operation PTZ Function Idle Motion Description Enable Check the box to enable the idle motion function Idle Motion Here you can set the preset auto scan pattern or tour to activate when the camera is idle Idle time Set the idle time from between 1 and 60 minutes PTZ Function ...

Page 17: ...at Up Down line limit Check the Enable box when both Up and Down lines are set When enabled clicking Live will move the camera to the set Up Down line position PTZ Function Time task Description Enable Check the box to enable the time task function Time Task No Select time task No to set 1 to 4 Time Task Action Here you can set preset auto scan pattern or tour to perform Auto Home Set auto home fu...

Page 18: ...18 Unit mm KOR Appendix 1 Product Dimension ...

Page 19: ...ies directly to a horizontal surface in either an upright or inverted position 2 NEXPTZ WL Wall mount bracket designed to mount the NEXPTZ SeriesCamera directly to a load bearing verticalsurface 3 NEXPTZ CN Corner adapter Bracket for use with the NEXPTZ WL to mount the NEXPTZ Series Camera to the corner of a structure 4 NEXPTZ PL Pole adapter Bracket for use with the NEXPTZ WL to mountthe NEXPTZ S...

Page 20: ...20 NEXPTZ WL NEXPTZ PD Unit mm Unit mm KOR Appendix 2 Additional Accessories ...

Page 21: ...21 NEXPTZ PL Unit mm NEXPTZ CN Unit mm KOR Appendix 2 Additional Accessories ...

Page 22: ...anty period of the product can be covered with a charge 2 In case of failure due to consumer negligence Careless handling by consumers or through repair or modification Repair or failure by someone other than the salesperson or technical staff Failure or damage caused by impact during the movement after installation Failure due to abnormal use of rated power and improper installation environment M...

Page 23: ...ywell Co Ltd Building Technologies Korea Address 5F Sangam IT Tower 434 Worldcup Buk ro Mapo gu Seoul Republic of Korea TEL 82 1522 8779 FAX 82 2 799 6188 E mail info security honeywell com Printed inKorea ...

Reviews: