Multinode Module Service
A-5
9/95
A
-
n
E
n=(0)
an unexpected interrupt has occurred, replace K2LCN
n=(1)
replace K2LCN; replace boards in slots b through c in turn;
n=(2)
no working DRAM, replace K2LCN
n=(3)
suspected program error, replace K2LCN
n=(5)
unverified cause of Level 7 interrupt, - replace K2LCN; replace the
power supply
n=(other)
replace K2LCN*
-
//
F
replace K2LCN*
-1
//
0
n=(1 thru 7),
(-) or (C)
replace K2LCN board; replace the module backplane or chassis
assembly
n=(other)
replace K2LCN*
-1
//
1
replace K2LCN*
-1
//
2
replace K2LCN*
-1
//
3
replace K2LCN*
-1
//
4
replace K2LCN*
Summary of Contents for MT13-520