page 7 of 24
Fig. B1
1. Guided type fall arrester
(24836 / 1017271)
(24837/
1017681)
2. Cable tensioner
(24798 / 1017380)
(24799 / 1017381)
3. Steel cable
4. Universal beam bracket
(24815 / 1017382)
(24814 / 1017383)
5. Rung clamp
(24807 / 1017384)
(24806 / 1017385)
6. Manual intermediate
(24838 / 1017370)
(24839 / 1017373)
7. Automatic intermediate
(24840 / 1017375)
8.Cable end piece
B2.
Warning!
The cable end attachments must always be fastened to suitably-
sized substructures
.
B3.
The upper cable anchor point most always be above the user.
B4.
Warning!
The cable must be sufficiently tensioned. The tension reading on the
cable tensioner must be between the minimum and the maximum
marking
.
B5.
The maximum distance between two intermediate brackets is 10
meter.
The intermediate brackets reduce and limit the deflections of the
steel cable. The deflection of the system depends on the total length
and the wind speed. The intermediates must avoid that the cable is
touching the construction and can get damaged.
For longer systems and in regions with high wind speed, we
recommend shorter distances between the intermediate brackets.
-
Systems length up to 55 m, 4 m between the intermediate
brackets.
-
Systems length more than 55 m, 3 m between the intermediate
brackets.
-
If the wind speed is more than 130 km/h, 3 m between the
intermediate brackets.