MBeacon
User’s Guide
7
1.1
Operation Area and Conditions
1.1.1 Hazardous Areas classified by Zones
MBeacon is intended to be used in hazardous areas classified
zone 0, zone 1 or zone 2, within the temperature range of -40º C to
+50º C, where gases of explosion groups IIA, IIB or IIC and T4
may be present.
1.1.2 Hazardous Areas classified by Divisions
MBeacon is intended to be used in hazardous areas classified for
Class I Div. 1 or 2, within the temperature range of
-40º C to +50º C, where gases of explosion groups A, B, C or D
and temperature class T4 may be present.
1.2
Instruction For Safe Use
Strictly follow the instructions for safe use. Application of the
MBeacon requires full understanding and strict observation of the
instructions.
1.3
Use In Hazardous Areas
Equipment which is intended for use in explosive atmospheres and
which has been assessed and certified according to international
regulations may be used only under specified conditions. The
components may not be modified in any way.
The appropriate regulations for service and repair must be properly
observed during such activities.