1

   Wire the 

Thermostat

2

   Power Up 

and Test

3

   Configure 

the System

T4M Thermostat 

Programmable Modulating Thermostat

Quick Start Installation Guide

Compatible with OpenTherm appliances only. 

Not

 compatible with 230V boilers, zone valve 

applications or 230V electric heating.

Installation in 3 steps...

Must be installed by a competent person.

To ensure your safety make sure the mains power 

is switched OFF before accessing wiring.

EN

OpenTherm

Communication

Find a suitable wall location away from draughts, 
direct sunlight or other heat sources, and where cables 
can be run from the boiler to the thermostat.  

B)   

Connect wires according 
to wiring diagrams and 
clip the cover closed. 

Wire the Thermostat

1

1.2-1.5m

OpenTherm Boiler

OpenTherm 

Boiler

Thermostat

A
B
C

T

OT OT

T
S
S

To prevent a short circuit from a loose wire -

•   

When using multi-core cables:

 Only remove enough outer 

insulation to allow secure fixing of the cores into the terminal block.

•   

When using single core cables:

 Secure them together with 

a cable tie as close as possible to the terminal block.

Polarity free

Press the   button to increase 
the temperature to maximum and 

check the boiler switches on

 

–  The heat demand icon   on the 

thermostat should be 

on

.

Now press the   button to decrease 
the temperature to minimum and 

check the boiler switches off

 

–  The heat demand icon   on the 

thermostat should also go 

off

.

Power Up the Heating System and do a quick functional test 
on the thermostat to check that it switches the boiler.

Power Up and Test

2

A)  

 Separate the wallplate from 
the thermostat, and using a 
screwdriver open the wallplate 
terminal cover to connect wires.

min 0.25mm²

max 1.5mm²

max 6mm