Lyric Controller Installation and Reference Guide
- 30 -
Programming Default
Programming Default
Programming Default
Programming Default Values
Values
Values
Values
Program Function
Program Function
Program Function
Program Function
Default Value
Default Value
Default Value
Default Value
Program Function
Program Function
Program Function
Program Function
Default Value
Default Value
Default Value
Default Value
Installer Code
4112
Test
Enabled
System Type
Test Restore
Enabled
RF Jam
RF Jam Log
Bypass
Enabled
RF House Code
0
Bypass Restore
Enabled
Events - Log All
Press to Log All
AC Loss
Enabled
Events - Log Alarm
Enabled
AC Loss Restore
Enabled
Events - Log Bypass
Enabled
Low Battery
Enabled
Events - Log Open/Close
Enabled
Low Battery Restore
Enabled
Events - Log Trouble
Enabled
RF Low Battery
Enabled
Non Security
Enabled
RF Low Battery Restore
Enabled
Remote Access Serial
Disabled
Options
Multi Mode Serial
Disabled
Number of Reports
2 Reports
Date Time
Alarm Report Delay
30 Sec.
Calendar
January 1, 2013
First Report Offset
6 Hrs
Enter Time
12:00 PM
Report Frequency
Never
Time Zone
Eastern (EST)
Sounder
Day Light Savings time
Yes
Burglary Alarm Sound
Yes
Start Month
March
Burglary Bell Timeout
4 Minutes
Start Week
Second
Fire Bell Timeout
4 Minutes
End Month
November
Arm Confirm
RF Key fob
End Week
First
System Settings
Communicator
Entry Delay 1
30 Seconds
Communications Path
WiFi
Entry Delay 2
30 Seconds
APL
Enabled
Exit Delay
60 Seconds
City ID
Blank
Backlight Timeout
No
CS ID
Blank
Quick Arm
Yes
Sub ID
Blank
Quick Exit
Yes
Supervision
30 Days
Restart Exit Time
Yes
Old Alarm Time
10 Minutes
Force Bypass
No
Remote Acc. Comm.
Disabled
Exit Warning
Yes
Multi Mode Comm.
Disabled
Auto Stay Arming
Yes
WiFi Fault Time (min)
00
Lack Of Usage Notify
Disabled
Use DHCP
Yes
Power-Up In Previous
Yes
NIC IP Address
255.255.255.255
Display Alarm Cancel
Yes
Subnet Mask
255.255.255.255
Display Exit Time
Yes
Gateway IP Address
255.255.255.255
(A) Cross Zone Delay
None
DNS Server IP Address
255.255.255.255
(A) Cross Zone 1
Disabled
GSM Fault Time
60
(A) Cross Zone 2
Disabled
GSM Rollover
No
(B) Cross Zone Delay
None
GSM 24 Hour Test
No
(B) Cross Zone 1
Disabled
Zones
(See Zone Programming Default Configuration)
(B) Cross Zone 2
Disabled
Keys
(See Zone Programming Default Configuration)
(C) Cross Zone Delay
None
Reporter
(C) Cross Zone 1
Disabled
Report Selection
(C) Cross Zone 2
Disabled
Arm Away
Enabled
(D) Cross Zone Delay
None
Arm Stay
Enabled
(D) Cross Zone 1
Disabled
Disarm
Enabled
(D) Cross Zone 2
Disabled
Exit Error
Enabled
Z-Wave
Recent Closing
Enabled
Z-Wave
Enabled
Event Log Full
Enabled
Temperature
Fahrenheit
Trouble
Enabled
Language
Trouble Restore
Enabled
Installer Language
English
Alarm Restore
Enabled
User Language
English
Alarm Cancel
Enabled
RF Keypad
(See Zone Programming Default Configuration)