Mounting TC C to combination control CG
▷
Use the adapter plate supplied to mount the
TC 1C to combination control CG.
▷
Connect the TC to the inlet pressure connec-
tion p
u
and the interspace pressure connection
p
z
of the inlet valve. Ensure that connections p
u
and p
z
on the CG are not reversed.
p
z
p
z
p
u
p
u
6
8
7
9
10
max. 250 Ncm
Mounting TC
▷
Connect the TC to the inlet pressure connection
p
u
and the interspace pressure connection p
z
of
the inlet valve.
▷
Use the adapter plate supplied for installation.
TC 2..R: Rp ¼
TC 2..N: ¼ NPT
Rp ¼ (¼ NPT)
p
u
p
z
p
z
▷
We recommend using Ermeto screw couplings
to attach the adapter plate to the gas solenoid
valve. It may be necessary to compensate the
distance to the valve housing.
p
u
▷
Only use approved sealing material to seal the
pipe connections.
250 Ncm
p
u
p
z
6
7
8
10
11
9
Connect the interspace pressure connection p
z
on the adapter plate to the space between the
valves using a 12 x 1.5 or 8 x 1 pipe.
p
z
p
z
▷
Ensure that connections p
u
and p
z
on the TC
and adapter plate are not reversed.
250 Ncm
p
u
p
z
6
7
8
10
11
Mounting TC
▷
Connect the TC to the inlet pressure connection
p
u
, the interspace pressure connection p
z
and
the outlet pressure connection p
d
of the inlet
valve. Ensure that connections p
u
, p
z
and p
d
on
the TC are not reversed.
▷
TC 3..R: Rp 1/4, TC 3..N: 1/4 NPT
p
z
p
d
p
z
p
u
p
u
p
d
p
z
▷
Use a 12 x 1.5 or 8 x 1 pipe for the pipe con-
nections.
p
z
p
d
p
z
p
u
p
u
p
d
p
z
6
Mount TC 3.
▷
Only use approved sealing material to seal the
pipe connections.
7
Seal the unused connection p
z
on the TC using