Unit uses too much salt
Improper brine refill setting
Check brine refill setting for proper salt
dosage
Improper settings
Check water hardness and reevaluate capa-
city setting specification
Excessive water usage
See problem "Excessive water in brine tank"
Leaking faucets, toilets, …
Repair or replace those items
Softener delivers salt water
Low water pressure
Check incoming water pressure.
Minimum is 2 bar
Excessive water in brine tank
See problem "Excessive water in brine tank"
Wrong size injector
Install correct injector
Excessive water in brine tank
Injector is plugged
Remove injector and clean ports
Faulty piston/seal assembly
Replace piston/seal assembly
Plugged or kinked drain line
Correct any kinking or plugging of drain line
Backwash flow controller closed off
Check backwash flow controller
Defective brine line flow control
Remplace brine line flow controller
Softener fails to draw brine
Injector is plugged
Remove injector and clean ports
Faulty piston assembly
Replace piston assembly
Brine line conntection leak
Inspect brine line during refill cycle for leaks
Drain line plugged creating excess back
pressure
Inspect drain line for blokkage
Drain Line too high or too long
Refer to drain line specification
Low inlet pressure
Increase inlet pressure to a minimum of
2 bar
Continuous flow to drain
Piston assembly failure
Remplace piston assembly
Motor failure
Remplace motor
Circuit board failure
Remplacer circuit board
Iron in softened water
Iron has fouled resin bed
Use iron reducing resin cleaner to clean
resin bed, and increase salt dosage or rege-
nerate more frequently.
Iron is not in a soluble state
Install iron reduction system
Prefilter failure
Check prefilter
Iron level excessive
Install iron reduction system
Loss of water pressure
Iron built up in resin
See problem above
Resin bed fouled with sand and sediment Rebed softener and install prefilter
Absent or incomplete LED display
Transformer unplugged
Plug transformer into uninterrupted outlet
No electric power at outlet
Repair outlet or use working outlet
Defective transformer
Change transformer
Defective meter
Unplug meter from PC board, if LED displays
lights appropriately, replace meter
Defective PC board
Replace PC board
Defective or unplugged Ethernet cable
Plug or change Ethernet cable
Control does not display correct time
of day
Power outage > 2 years
Reset time of day
Power outage < 2 years - Time of day flas-
hing - Battery discharged
Replace lithium battery
No "softening" display when water is
flowing
Bypass valve in bypass position
Put bypass valve in service position
Meter connection disconnected
Connect meter to PC board
Restricted/stalled meter turbine
Remove meter and check for rotation, clean
foreign material
Defective meter
Replace meter
Defective PC board
Replace PC board
Problem
Cause
Remedy