background image

 

 

Base Models 

The base model is used as the baseline configuration from which to build the variant configuration options and 
models. 

Name 

Description 

201-104-P00-B578S-B0 

Base Model in a surface mount configuration. 

Individual Components 

Below are a set of components such as housings, PCBA’s and harnesses which can be ordered or added for final 
configuration. 

OP/N Code 

Description 

202-104 

PC-803, B578S, B578N logic board PCBA 

02-9949 

PC-803, B578S, B578N PoE power supply PCBA 

204-005 

Meanwell GS15A 100-240VAC, +12VDC 15W SMPS 

262-301 

AC Power Cable (used with 204-005) 

53-8083 

B57x DIN rail latch 

53-9918 

B57x DIN rail bottom housing 

53-8292 

B57x DIN rail top housing 

253-532 

B57x Surface mount bottom housing 

253-533 

B57x Surface mount top housing 

04-8047.7B 

7’ black CAT5E patch cable 

62-2035 

3 pin cable, 300mm 

241-018 x 4 

FASTENER SCREW 6x1.25 OVAL PHILIPS 

Document Revision History 

Revision 

Date Issued 

 Reason 

0.1 

12-Apr-2014 

FCC for B578 

0.2 

23-Apr-2014 

Formatted 

0.3 

03-Jun-2014 

Input from “NPI: CBL32 Dimmer 
andController Platform Updates

” 

 

Summary of Contents for INNCOM B578

Page 1: ... in room RF traffic to Ethernet towards the server Note The device will generally be referred to as the B578 throughout this document Statements specific to a particular configuration will be noted accordingly Features Supports CBL32 control algorithms RS485 System Interface dongle 10MBit Ethernet Available in PoE and 12VDC powered models 128 bit AES encryption Ethernet link and RF network Typical...

Page 2: ... interference that may cause undesired operation This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used i...

Page 3: ...etwork The B578 can be attached to an X type DIN rail To attach the B578 to a DIN rail pull the tab Figure 3 down and attach the bottom of the housing to the DIN rail always mount the DIN rail with the tab at the bottom Once the unit is sitting flush on the rail release the tab To remove the B578 from the DIN rail pull the tab down and lift the bottom edge of the unit off the DIN rail first This e...

Page 4: ...e B578 as described above and remove the PCBA which is held in place by 4 tangs located at its perimeter Once the PCBA is removed locate the 4 countersink posts mount the bottom housing to the intended fixture using a self tapping screw mount the PCBA back on to the bottom housing make the necessary wire connections see Headers and Connectors below connect power to the DC jack plug in Ethernet con...

Page 5: ...shes fast to indicate a valid CIS connection Flashes slow to indicate 75 seconds have passed with no packets from the CIS network Blue Toggles when RF Rx tunnel packet is received Power Supplies The B578 provides power supply options for three specific applications For each configuration follow the current consumption ratings below to determine the device s power budget Mode Peak Current Consumpti...

Page 6: ... up the unit FCC Statement This device complies with part 15 of the FCC Rules Operation is subject to the following two conditions 1 this device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation IC Statement This Class B Digital Apparatus complies with Candian ICES 003 Cet apparel numerique de la cla...

Page 7: ...his character set defines the power supply options available for the B57x platform OP N Code Power Supply Type Part Number P00 No Power Supply POE Power over Ethernet 02 9499 P12 External inline power supply with AC cable 204 005 262 301 Configuration Option This character set defines the software configuration of B57x OP N Code Logic Board Type Part Number PC 803 4G Ethernet to RF protocol conver...

Page 8: ...8 Copyright 2014 INNCOM by Honeywell OP N Code Logic Board Type Part Number A0 DIN Rail Mounted Housings See Individual Components chapter B0 Surface Mounted Housings See Individual Components chapter ...

Page 9: ...d PCBA 02 9949 PC 803 B578S B578N PoE power supply PCBA 204 005 Meanwell GS15A 100 240VAC 12VDC 15W SMPS 262 301 AC Power Cable used with 204 005 53 8083 B57x DIN rail latch 53 9918 B57x DIN rail bottom housing 53 8292 B57x DIN rail top housing 253 532 B57x Surface mount bottom housing 253 533 B57x Surface mount top housing 04 8047 7B 7 black CAT5E patch cable 62 2035 3 pin cable 300mm 241 018 x 4...