IDENT-KEY
block lock
IDENT-KEY
rosette
Connecting cable
Attention!
Make sure that
there is sufficient
space at this point
for the rosette
connecting cable!
Door leaf
section
Drill holes for
rosette fixture
(use the drilling pattern)
5.
Put on rosette and inner plate and tighten the threaded sleeves slightly.
Then the cylinder is slid through the rosette into the cylinder opening of the block lock (
) and then fix it with the en-
closed screw.
When
make sure that the flat-band cable of the rosette is
not damaged.
Then tighten the threaded sleeves (rosette fixture) completely.
6. Install the cable passage.
a) Take care that the hose sockets are plugged at the ends of the protective flexible metal hose.
Thus, damage of the block lock cable is avoided.
b) Tighten the fixing caps and make sure that the block lock cable is not damaged by the fixing
screws.
7.
Adjust and mount the face plate.
lock
catch in direction of the face plate, 90° towards the right or the left
inserting the cylinder
Mounting and Connection Instructions IK2 block lock